In addition to daily maintenance tasks, use an ash vacuum to clean
the inside of the firebox.
Remove the firepot from the pot holder and vacuum beneath.
Be sure to remove any ash from the incoming ignitor tube. SEE
FIGURE 35.
MONTHLY MAINTENANCE
The exhaust venting system should be inspected at least once
per month to determine if cleaning is necessary.
ANNUALLY/ BIANNUALLY
Remove and clean the exhaust venting.
Remove and clean the combustion motor, housing and impellers.
To remove the combustion motor, you will have to remove
the side panel on the stove. To remove the panel:
•
Loosen the three screws located toward the front of the
rear left panel using an 1/8” allen wrench. It is not neces-
sary to completely remove the screws; just loosening them
will suffice. SEE FIGURE 36.
•
Remove two phillips screws located at the rear of the panel, one
at the top and one at the bottom of the panel. SEE FIGURE 37.
•
Pivot rear panel outward and push front of panel inward to
release and remove panel. SEE FIGURE 38.
Once you’ve removed the side panel, you can remove and clean
the combustion motor, housing and impellers. SEE FIGURE 39.
Figure 35: Remove ash from ignitor tube (underneath firepot)
Figure 38: Remove combustion motor and clean
Figure 36: Remove side panel screws using 1/8 allen wrench
Figure 37: Remove Phillips screws at rear of side panel at the top and bottom
of the panel