KSUPS
Solenoid Controlled Switch
User Manual - Original Language Version
While every effort has been made to ensure the accuracy of the information provided, no liability can be taken for any errors or omission.
Castell Safety International Limited reserves the right to alter specifi cations and introduce improvements without prior notice.
3 of 6
www.castell.com
U-KSUPS-001-E Issue 1
Technical Data
Temperature rating
Ambient temperature of stages: open at 100% lu/lth - 55°C during 24 hours with peaks up to 60°C,
enclosed at 100% lthe - 35°C during 24 hours with peaks up to 40°C
Storage temperature: -40°C to 85°C (in case temperature below -5°C no shock load permissible)
Type of mounting
1/4“ or M6
Weight
0,6 kg
Material
Brass/Stainless steel
Power isolation
20A
Switch approvals
BS,UL,CSA & VDE
MTTF Certifi cation
Available on request
We, the manufacturers, declare that the components, detailed herein and placed on the market, comply with all the essential
health and safety requirements applying to them.
Empowered signatory:
Mr T.C. Whelan
Managing Director
EC-Declaration
Application
A typical application of KSUPS Solenoid Controleld
Switch is machine guarding. It is usually used in
combination with an Access Interlock such as the Salus
for part body access or an Access Interlock with an
exchange key for full body access control.
The KSUPS breaks the machine safety circuit, ensuring a
machine is shut down. Once the Machine has completed
the cycle, an exetrnal signal is received by the solenoid.
The LED will illuminate and the key can be turned and
removed, ensuring the power is locked out. The key can
then be taken to the Salus Automatic Access Interlock to
enable access to the machine.
The machine cannot be restarted until the door is closed,
the bolt is trapped in the Access Interlock and the key
is removed and taken to the KSUPS solenoid controlled
switch.
KSUPS
Solenoid Controleld Switch
Salus Access Interlock