MI/2029 - 2
a
ed. ENG - 06/2017
PLANO bollard
single/double emission
1
product in compliance with the requirements
of the European Community Directories
installation and maintenance sheet
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with
or transformed and it must be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms
of guarantee. THE COMPANY CANNOT BE HELD RESPONSIBLE FOR DAMAGE CAUSED BY INCORRECT ASSEMBLY.
Quality control: In case of complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial
number that recognizes the fixture. / Specifications are subject to change without notice!
3
MAX Ø10 mm
x4
x4
Power supply connection: make electrical connection respecting polarities.
ELECTRICAL CONNECTIONS:
2
4
3
L
N
Ø7 - Ø12 mm
92
A
(mm)
B
(mm)
H
(mm)
SLED Cluster
1 SLED (X4) sink
W
6
Kg
3,5
552
2801
92
Cod.
H
B
A
70
45°
x4
1
DRILL HOLES IN THE BASEMENT
2
INSTALL THE BASE WITH SCREWS,
WASHERS AND PLUGS
H
B
A
Cod. 2802
Cod. 2801
ATTENTION CLOSE THE CONNECTOR
WITH A TORQUE OF 2,5 Nm (22lbf/in)
RIGHT INSTALLATION
FOR Cod. D53/1-TF
ONLY three core flexible neoprene rubber type H07RN-F.
NO PVC NO SINGLE WIRES (EN 60598-1)
90
2802
1 SLED (X4) flat 6 2,8
552
90
NB: tools, screws, washer and dowels not included
ATTENTION
Switch-off the power supply
before any installation and
maintenance operations
During the installation use proper screws
suitable for the considered support
2a
OPTIONAL FIXING SYSTEM
(Cod.D53/1-TF)
Cement the optional plate and fix the base with provided
bolts and washers
Cod. D53/1-TF
PIERCING TERMINAL
CONNECTOR
Version
Features - meaning of the symbols shown on the label:
IP65
Totally dust proof.
Protected against water jets
from any directions.
Cannot be disposed of as urban waste. Separate
waste collection mandatory atend of product’s
life cycle. “WEEE member consortium: Ecolight.”
National Registry of Manufacturers
n°: IT0801000000166”
Replace the modules
with damaged screens.
Contact us or one of our
resellers.
Simple insulation:
earth required.
Class I