Electrical connection - wiring plug code 31

We only supply the 2-pole plug code 31

We do not supply the electrical cable and plug to be connected to the tractor 

because the length of the cable may vary significantly according to the size 

of the tank and the position of the socket on the tractor.

The following is a simple explanation on how to properly wire the electrical 

cable to our plug, in order not to invert its polarity.

With regards to the plug to be connected to the tractor, following the 

manufacturer’s instructions for the model to be used.

58 +

A

Recommended pump

medium / high pressure   

 

bar 

 

min 20 – max 50

Operating pressure 

 

 

bar 

 

min 10 - max 25

Recommended operating pressure  

bar 

 

10

minimum required flow rate 

 

l/min   

50

The capacity of the pump must be suitable for the volume of liquid to be sprayed.

Summary of Contents for DUPI

Page 1: ...Operation and maintenance manual CASOTTI SPRAYERS Quello che mancava Revision no 15 2019 DUPIGET PRECISION WITH REVOLVING UNIONS Code DUPI P DUPIGET PRECISION WITH PIPES Code DUPI...

Page 2: ...age 9 Use of the machine page 10 Warranty page 11 TECHNICAL INFORMATION OPERATION Description of the machine page 13 Application to an existing system comprising tank and pump page 13 Electrical conne...

Page 3: ...am page 20 Distribution uniformity table CV according to the operating width page 21 Changing the oscillation angle page 22 Periodical checks and calibration page 22 Specification page 23 Wiring diagr...

Page 4: ...ble and plug to be connected to the tractor because the length of the cable may vary significantly according to the size of the tank and the position of the socket on the tractor Code C S Qty 1 Code 3...

Page 5: ...5 Installation A...

Page 6: ...6 For more information on the electrical connection follow the instructions on the next page 110 LH 40A 110 RH 12A M300 12A 40A...

Page 7: ...ollowing is a simple explanation on how to properly wire the electrical cable to our plug in order not to invert its polarity With regards to the plug to be connected to the tractor following the manu...

Page 8: ...achine Safety standards The user must thoroughly read the technical operating instructions pertaining to proper use of the machine This manual must be read before operating the machine and must always...

Page 9: ...icity Do not use the machine when there are unusual weather conditions and the danger of heavy storms Transport handling and storage Check the following upon delivery The bill of materials and the act...

Page 10: ...d is considered an improper use The machine must not be used in case of wind over 5 km h near waterways or in other areas that are deemed to be sensitive and vulnerable to contamination from pesticide...

Page 11: ...Lack of or improper maintenance User negligence when operating the sprayer Use of tools that are not suitable for maintenance Modifications or tampering performed or commissioned without an explicit...

Page 12: ...12...

Page 13: ...0A 1 plug code 31 2 revolving square unions code M300 The two curves code 12A and 40A mount as standard a round hole nozzle 2 5 mm and an anti drip The machine body is of the SUPER type there are thre...

Page 14: ...e on the front When connecting the cable to the plug the positive pole must be inserted into no 58 If cables are inverted the gear motor may be irreparably damaged Insert the power plug code 31 to the...

Page 15: ...proper movement of the two curves is described in the following figure Hydraulic connection and maintenance Pipes coming from the pump must be connected directly to the supplied revolving square unio...

Page 16: ...the vegetation The actual operating width including the side fading is always approx 13 m but the principle of calibrated overlap allows continuing through lanes with different distances without any...

Page 17: ...distance to be kept from the edge remember that the distribution on the short side from the centre of the sprayer is approx 3 m including 1 m of fading If used to enter the field proceed at approx 3 4...

Page 18: ...uid to be sprayed per hectare see the following formula D Q x 600 L x V where D Quantity to spray in l hectare Q Overall flow rate of nozzles in l min L Operating working width V Speed That is Overall...

Page 19: ...and the measures are approximated DUPIGET PRECISION flow rate table equal distance 9 m 10 bar Nozzles l min C V 4 km h 5 km h 6 km h 7 km h T 1 5 T 1 5 8 4 9 4 l ha 140 110 90 80 T 2 0 T 2 0 14 8 3 l...

Page 20: ...nozzles Standard version 2 5 mm ml min Metres ml min Metres 0 9 18 27 Distribution diagram with equal distance 9 m Standard version 2 5 mm Distribution diagram with sum of passes equal distance 9 m St...

Page 21: ...m 10 bar Operating width Equal distance m 4 5 5 5 5 6 6 5 Distribution uniformity CV 2 2 1 4 5 4 7 6 9 3 l ha 370 340 310 280 260 Operating width Equal distance m 7 7 5 8 8 5 9 Distribution uniformity...

Page 22: ...adjustment lever tighten the bolt and then check whether the angle is as desired The oscillation angle of the two central stainless steel pipes varies between 75 and 205 The oscillation angle of the...

Page 23: ...00 Max 1 000 L hectare Flow rate per minute Min 20 Max 180 l min Pressure Min 10 Max 50 bar Voltage 12 V Current absorption 2 5 6 A Noise level Less than 65 dB Wiring diagram C ON OFF ON SWITCH SOCKET...

Page 24: ...available to provide all required information No liquid is sprayed Make sure the tank is not empty Check the operation of the pump Nozzle holding curves do not oscillate Check that electrical current...

Page 25: ...er curves by pumping lubricating grease into the greaser It is not possible to tell when lubrication is necessary therefore perform 1 pumping a year The Casotti sprayer as designed does not require sp...

Page 26: ...lassic models being marketed since 1966 Assembling pipes Screw the pipe holding support on the cast Pipes code 5 must be installed one on the central pipe and one on the adjacent pipe and secured to t...

Page 27: ...27 D CENTRAL PIPE Code 23 Code 5 CENTRAL PIPE...

Page 28: ...th anti drip 14 Z20 Central pipe with gear Z20 small 14 Z40 Central pipe with gear Z40 large 15 Adjustable lever 16 Gear motor crank 17 L gasket 20 Widia round hole nozzle 20 C20 Ceramic round hole no...

Page 29: ...anti drip 42 Gear motor 12V 2v 72rpm 47 i Stainless steel bushing 51 Brass nozzle holder 54 Green flanged bushing Iglidur D 58 55 teeth gear for gear motor TGE 428 M33 i Stainless steel nut M300 Revo...

Page 30: ...30 M300 12A 40A...

Page 31: ...31 1 S 3 S 5 12A 14 Z40 15 17 19 V12 19 V15 19 V18 2 S 4 14 Z20 16 E...

Page 32: ...32 21 S 23 27 28 30 31 20 C20 20 C25 42 29 40A...

Page 33: ...33 47 i 51 58 M33 i 87 54 M300 103 104 E...

Page 34: ...nery or to be as sembled together with other machinery to form a complex assembly that operates as one The machine cannot be commissioned until the machinery it is going to be included into and of whi...

Page 35: ...Serial number Year of manufacture F A C S I M I L E O R I G I N A L A T T A C H E D Is compliant with the provisions of Machinery Directive 2006 42 EC Name and address of the person authorised to com...

Page 36: ...e com IrroratoriCasotti Operation and maintenance manual Translation of original instructions Revision no 15 of 12 04 2019 The information in this document is subject to changes without notice Casotti...

Reviews: