CONTROL UNIT WITH TIMER

CABLE WITH 2-POLE 
PLUG TO CONNECT 
THE PHOTOCELL

Main 

switch

CABLE WITH 2-POLE 
PLUG TO CONNECT 
THE SOLENOID VALVE

12V power supply cable with plug

Plant counter

Timer

Continuous operation

ON

OFF

ON

OFF

The control unit with timer is used to adjust the closing time of the solenoid 
valve (energisation delay), allowing the fluid to be discharged accurately.
A magnet is installed on the back of the control unit, in order to place it 
comfortably in the cab.
AQUILOTTO is supplied power by connecting the control unit plug to the 
12V power outlet of the tractor.
The main switch turns the entire device on and off; in OFF position, it also 
cut off power supply to the  optical reader and to the solenoid valve.
The  continuous operation switch in ON position is used to keep the 
solenoid valve always open, effectively bypassing the impulse coming 
from the Photocell and discharging the fluid continuously.

Summary of Contents for AQUILOTTO 1 SIDE FC8

Page 1: ...Made in Italy since 1966 Quello che mancava 1 SIDE code FC8 Version 6 2018 Instruction for the installation and the adjustment CASOTTI DEVICE TO INTERRUPT FLUID SPILLS BETWEEN TREES...

Page 2: ...alve The function of the optical reader is to find the presence of the trunk or leaves and give the impulse for the fluid opening The Control unit allows accurately controlling all functions of AQUILO...

Page 3: ...scharged accurately A magnet is installed on the back of the control unit in order to place it comfortably in the cab AQUILOTTO is supplied power by connecting the control unit plug to the 12V power o...

Page 4: ...ximum reading distance of the photocell is 400 cm The maximum reading can change according to the weather and the position of the sun The metal case containing the photocell has two functions to preve...

Page 5: ...R The frame shall be constructed considering dimensions of Aquilotto to avoid projection from the outline of the tank AQUILOTTO movement axis 1 150 cm about frame to be applied to the tank AQUILOTTO m...

Page 6: ...rformed earlier and therefore the distance between the fluid discharge and the leaf increases If the optical reader is moved closer to the nozzles the reading is performed later and therefore the dist...

Page 7: ...ply with the relevant ON OFF main switch before operating selectors A B C Selector A operating mode selector must always be in D position Selector B time unit selector is normally set to seconds Selec...

Page 8: ...si 201 1 91 5 3 SC 1 2Vdc 27w 40 bar 580 psi 200 1 91 5 4 SC 1 2Vdc 1 0w 20 bar 290 psi 201 1 91 5 3 SC 1 2Vdc 27w 40 bar 580 psi 200 1 91 5 4 SC 1 2Vdc 1 0w 20 bar 290 psi SOLENOID VALVE technical fe...

Page 9: ...30 mesh 1 0 C 80 C 201 1915 3 SC 27w coil 40bar 580 psi DIN43650 A ISO4400 PG9 connector without cable Max operating pressure 40 bar Weight 1 1 kg Materials brass stainless steel FKM seals high resist...

Page 10: ...he solenoid valve body see section plane FAILURE The fluid never comes out from the nozzles SOLUTION Check that the solenoid valve is connected to the power supply Check that the solenoid valve is con...

Page 11: ...11 19 10 10 12 51 SPARE PARTS 201 1915 3 Foto ad alta risoluzione High resolution photos rts cod rts cod rts cod 201 1915 3 Scarica PDF Download PDF...

Page 12: ...12 PHOTOCELL technical information...

Page 13: ...13...

Page 14: ...14...

Page 15: ...tment AQUILOTTO 1 SIDE Translation of original instructions Version 6 2018 Information herein can be modified at any moment without notice Casotti is not responsible for omissions technical or editing...

Page 16: ...tori Via Cerreto 10 i 43035 Felino Parma Tel 39 0521831311 Fax 39 0521 336892 info casotti it www casotti it facebook com CasottiIrroratori youtube com IrroratoriCasotti Made in Italy since 1966 Quell...