54
RFID tag (ISO15693)
Table 3.27 Condition
Minimum operating magnetic filed
1.5A/m over
Direction
Parallel direction with dislay panel
Angle
Parallel with display panel
Range
See Figure 3.4
Distance
0mm (Contact with case) – 50mm
Style
ISO7810(JISX6301) standard card's style
Rear
Figure 3.5
Figure 3.6
Note:
There is possibility to change scanning range or can not scan by RFID tag/ Contactless Smart Card
antenna style or power consumption.
Especially, there is a case which ISO14443 TypeB card such as IC driver license need 1.5A/m over
magnetic field strength.
Antenna sensitivity most strength location is center of scanner filter.
0mm(Contact with case) - 50mm
Parallel with display panel.