background image

83

Ad

v

anced Operations and Setups

E

<CURRENCY EXCHANGE>

Description

Choice

Program code

Define amount symbol. (0, 1 ~ 2)
(“0” means local currency symbol.)

Define foreign currency totalizer. (0, 1 ~ 2)
(“0” treats as “1”.)

Rounding:
Round off = 0, cut off = 1, round up = 2

Always “0”

Monetary mode (0 ~ 9):

º00

 = 2, 

º0

 = 1, 

0

 = 0, 

º000

 = 3

Monetary symbol for decimal

Monetary symbol for separator

Always “0”

a

b

:

D

7

:

D

6

:

D

5

;

D

4

:

D

3

:

(a+b)

D

2

;

D

1

Significant

number

Significant

number

Significant

number

Significant

number

Decimal = 0

Comma = 1

Comma = 0

Decimal = 4

<MULTIPLICATION>,

Description

Choice

Program code

Multiplication procedure: (<X> only)

1

 Quantity 

×

 Amount, 

2

 Amount 

×

 Quantity

Rounding:
Round off = 0, cut off = 1, round up = 2

Always “0000”

:

D

6

:

D

5

; ; ; ;

D

4

D

3

D

2

D

1

1

 = 0

2

 = 1

Significant

number

Description

Choice

Program code

Taxable status (00, 01 ~ 04)
(“00” means taxable 1.)

Always “000000”

: :

D

8   

D

7

; ; ; ; ; ;

D

6

D

5

D

4

D

3

D

2

D

1

Significant

numbers

<SUBTOTAL>, <MERCHANDISE SUBTOTAL>

Description

Choice

Program code

Print when key is pressed.

Always “00000”

:

D

6

; ; ; ; ;

D

5

D

4

D

3

D

2

D

1

No  = 0
Yes = 4

<TAX SHIFT>

<AGE VERIFICATION>

Description

Choice

Program code

Print when this key is registered.

Always “000”

Always “000000”

:

D

10

; ; ;

D

9   

D

8  

D

7

; ; ; ; ; ;

D

6

D

5

D

4

D

3

D

2

D

1

Yes = 0
No  = 1

Summary of Contents for SE-C2000

Page 1: ...ELECTRONIC CASH REGISTER USER S MANUAL Eu Di U K THANK YOU YOUR RECEIPT CALL AGAIN GROCERY DAIRY H B A FROZEN FOOD DELICATESSEN SE C2000 ...

Page 2: ...ene thinner or any other volatile agent Never operate the cash register while your hands are wet Be sure to check the sticker on the side of the cash register to make sure that its voltage matches that of the power supply in the area Important Your new cash register has been carefully tested before shipment to ensure proper operation Safety devices eliminate worries about breakdowns resulting from...

Page 3: ...ference Consult your CASIO dealer if you have any questions about points not specifically covered in this manual Manufacturer CASIO COMPUTER CO LTD 6 2 Hon machi 1 chome Shibuya ku Tokyo 151 8543 Japan Representative within the European Union CASIO EUROPE GmbH Bornbarch 10 22848 Norderstedt Germany Please keep all information for future reference The main plug on this equipment must be used to dis...

Page 4: ...e will be indicated The symbol indicates a restriction In this symbol the type of actual restriction removal of the power plug from an outlet in this case is indicated Warning Handling the register Should the register malfunction start to emit smoke or a strange odor or otherwise behave abnormally immediately shut down the power and unplug the AC plug from the power outlet Continued use creates th...

Page 5: ... power cord or plug requires repair or maintenance Caution Do not place the register on an unstable or uneven surface Doing so can cause the register especially when the drawer is open to fall creating the danger of malfunction fire and electric shock Do not place the register in the following areas Areas where the register will be subject to large amounts of humidity or dust or directly exposed t...

Page 6: ...0 General guide 20 Roll paper 20 Mode key 20 Drawer 20 Drawer lock Drawer key 20 Magnetic plate 20 Mode switch 21 How to set the Pop up display 21 How to set the menu sheet 21 Display 22 Display panel 22 Main display 22 Customer display 22 Keyboard 24 Allocatable functions 26 Basic Operations and Setups 28 How to read the printouts 28 How to use your cash register 29 Before business hours 30 Check...

Page 7: ...eceived on account 43 Registering money paid out 43 No sale registration 43 Making corrections in a registration 44 To correct an item you input but not yet registered 44 To correct an item you input and registered 45 To cancel all items in a transaction 46 Printing the daily sales reset report 47 Advanced Operations 48 Using clerk functions 48 Enable clerk feature 48 Assigning a clerk 48 Clerk nu...

Page 8: ...rs 68 Report descriptor 68 Text recall character 69 Grand total special character 69 Report title 69 Machine feature program 70 General control program 70 Programming procedure 70 Program data by address code 70 Address code 02 machine number 70 Address code 03 consecutive number 70 Address code 04 tax system rounding 70 Address code 05 print control for receipt 71 Address code 06 calculation oper...

Page 9: ...orts except open check 89 To print open check read report 89 To print daily reset reports except open check 90 To print open check reset report 90 Read reset report sample 91 To print the periodic 1 2 sales read reset reports 94 Reading the cash register s program 96 To print unit price rate program except PLU 96 To print key descriptor name message program except PLU 96 To print the machine progr...

Page 10: ...when you unplug the cash register Be sure to install these batteries 4 Replace the battery compartment cover 5 Close the platen arm and replace the printer cover WARNING Never try to recharge the batteries supplied with the unit Do not expose batteries to direct heat let them become shorted or try to take them apart Keep batteries out of the reach of small children If your child should swallow a b...

Page 11: ...he leading end of the paper over the printer To install receipt paper Important Take away the head protection sheet from the printer and close the platen arm Caution in handling the thermal paper Never touch the printer head and the platen Unpack the thermal paper just before your use Avoid heat direct sunlight Avoid dusty and humid places for storage Do not scratch the paper Do not keep the print...

Page 12: ...rm slowly until it locks steadily Step 6 Remove the paper guide of the take up reel Step 7 Slide the leading end of the paper into the groove on the spindle of the take up reel and wind it onto the reel two or three turns Step 8 Replace the paper guide of the take up reel Step 9 Place the take up reel into place behind the printer above the roll paper Step 10 Press the j key to take up any slack i...

Page 13: ... wall outlet 4 Insert the mode key marked PGM into the mode switch 5 Turn the mode switch to the PGM position 6 Set the date 7 Set the time 1 Enter current date in year month day order and press the X DATE TIME Example 15 June 2008 2 080615X 2 Press C key Example C 1 Enter current time in 24 hour system and press the X DATE TIME Example 08 30 a m 2 0830X 9 45 p m 2 2145X 2 Press C key Example C X ...

Page 14: ...ements Important After you program the tax calculations you also have to individually specify which departments page 33 and PLUs page 35 are to be taxed Programming tax calculations 8 Tax table programming Tax table No Tax table 1 1 Tax table 2 2 Tax table 3 3 Tax table 4 4 63s 61 6 6 12 34 6a6 6 6 a 6 s Tax rate 6 25 6 25 7 7 Rounding Round off 50 Cut off 00 Round up 90 Tax system Add in 03 Add o...

Page 15: ...played Important When you are using Danish rounding you can use the a key to register tendered amount in which the last right most digits are 00 25 50 or 75 This restriction does not apply to the h and k keys IF 1 rounding Last 1 digit of subtotal Result 0 2 0 3 7 5 8 9 10 D10 D1 1000000000 IF 2 rounding Last 1 digit of subtotal Result 0 4 0 5 9 10 D10 D1 2000000000 Danish rounding Last 2 digit of...

Page 16: ... GST INCLUDED is set to the TX1 descriptor 4 TAXABLE AMT is set to the TA1 descriptor 5 Total line is printed even in direct cash sale 6 Australian rounding is set 7 is set to the monetary symbol 8 Print MOF message on receipt 9 Tax 10 tax rate add in tax fraction round off is set to the tax table 1 No data is set to other tax tables 0 The taxable amount and tax amount except TA1 TX1 are not print...

Page 17: ... 47 Maximum 6 digit unit price can be set to the department Refer to page 33 Tax calculation status can be set to the department Refer to page 33 Maximum 6 digit unit price can be set to the PLU Refer to page 35 Tax calculation status can be set to the PLU Refer to page 35 0 01 99 99 rate can be set to the Discount key Refer to page 38 Tax calculation status can be set to the Discount key Refer to...

Page 18: ...Arrangement key registrations 60 Tips 60 Item correction by using VOID key 61 Addition 61 Department PLU name selection set 62 Preset message graphic selection set 62 Character manual input 63 Machine feature program 70 Key function program 78 Keyboard layout change 87 Individual item read report 88 Daily read report 89 PLU report 89 Monthly report 89 Hourly report 89 Group report 89 Flash report ...

Page 19: ...19 Getting Started E ...

Page 20: ...report The drawer will not open if it is locked with the drawer key Drawer lock Drawer key Use the drawer key to lock and unlock the drawer Operator key Program key OP General guide This part of the manual introduces you to the cash register and provides a general explanation of its various parts display drawer keyboard pop up display printer cover take up reel main operator customer PGM Magnetic ...

Page 21: ...reakfast Ebreakfast Fbreakfast Gbreakfast Hbreakfast Ibreakfast Adinner Bdinner Cdinner Edinner Edinner Fdinner Gdinner Hdinner Idinner Alunch Blunch Clunch Dlunch Elunch Flunch Glunch Hlunch Ilunch Asetmenu Bsetment Csetmenu Dsetmenu Esetmenu Fsetmenu Gsetmenu Hsetmenu Isetmenu Abreakfast Bbreakfast Cbreakfast Dbreakfast Ebreakfast Fbreakfast Gbreakfast Hbreakfast Ibreakfast Adinner Bdinner Cdinn...

Page 22: ...22 Introducing the Register E Display Display panel Main display Customer display 1 34 3 ST 123 45 PRETZEL 1 34 RPT AMOUNT T1 T2 T3 T4 TOTAL CHANGE ...

Page 23: ...ay numeric display Item registration by department PLU Repeat registration Totalize operation 50 3 66 3 50 3 5 Number of repeats Anytime you perform a repeat registration page 31 36 the number of repeats appears here Note that only one digit is displayed for the number of repeats This means that a 5 could mean 5 15 or even 25 repeats 6 Tendered amount When the tender operation is made the entered ...

Page 24: ... 8 Tax program key Use this key to set the tax status and tax table 9 Clerk number key o Use this key to sign clerk on and off the register 0 Sign off key Å Use this key to sign clerk off the register A Received on account key r Use this key following a numeric entry to register money received for non sale transactions B Paid out key P Use this key following a numeric entry to register money paid ...

Page 25: ... total amount to the previous balance to obtain a new balance P New check key N Use this key in a check tracking system to input a new check number in order to open a new check under that number Q Old check key O Use this key in a check tracking system to input the number of an existing check previously created by the new check key whose details are stored in the check tracking memory R Non add No...

Page 26: ...s key to register a tax amount Menu shift Use this key to shift flat PLU keys to 1st 3rd menu Merchandise subtotal Use this key to obtain subtotal excluding the add on tax amount and the previous balance Multiplication Use this key to input a quantity for a multiplication operation Between transactions this key displays the current time and date New balance Use this key for adding the latest regis...

Page 27: ...e this key following a numeric entry to register money received for non sale transactions Reduction minus Use this key to input values for reduction Refund Use this key to input refund amounts and void certain entries Sign off Use this key to sign clerk off the register Subtotal Use this key to display and print the current subtotal includes add on tax amount Tax status shift 1 Use this key to cha...

Page 28: ...wide Also all sample receipts and journals are printout images THANK YOU CALL AGAIN COMMERCIAL MESSAGE COMMERCIAL MESSAGE COMMERCIAL MESSAGE COMMERCIAL MESSAGE New Year Sale 1st Anniversary 10 OFF REG 03 06 2008 11 58 C01 0001 000123 1 DEPT001 T1 1 00 1 DEPT002 T1 2 00 5 DEPT003 5 00 7 No TA1 3 00 TX1 0 15 TL 8 15 CASH 10 00 CG 1 85 BOTTOM MESSAGE BOTTOM MESSAGE BOTTOM MESSAGE BOTTOM MESSAGE Logo ...

Page 29: ...k the date and time Page 30 Register transactions Page 31 Periodically read totals Page 88 Reset the daily totals Page 47 90 Remove the journal Page 104 Empty the cash drawer and leave it open Page 20 Take the cash and journal to the office How to use your cash register The following describes the general procedure you should use in order to get the most out of your cash register BEFORE business h...

Page 30: ... following procedure to open the drawer without registering an item This operation must be performed out of a sale You can use the r key instead of this key See page 43 Opening the drawer without a sale OPERATION RECEIPT N Date time appears on the display Clears the date time display NS X REG OFF RF PGM Z X2 Z2 OP PGM Mode switch X REG OFF RF PGM Z X2 Z2 OP PGM Mode switch REG 00 RPT AMOUNT T1 T2 ...

Page 31: ...RATION RECEIPT 150 s 10 F Unit price 12 34 Item Quantity 1 Dept 1 Payment Cash 20 00 Unit price Department Amount tendered Unit price 1 00 Item Quantity 1 Dept 1 Payment Cash 1 00 Unit price 1 50 Item Quantity 3 Dept 1 Payment Cash 10 00 1 DEPT001 12 34 TL 12 34 CASH 20 00 CG 7 66 Total amount Amount tendered Change 1 DEPT001 1 00 TL 1 00 CASH 1 00 Department No unit price Total amount 1 DEPT001 1...

Page 32: ...tment number OPERATION RECEIPT 31 13 F If is not allocated on the keyboard key allocation is necessary Designating upper department press first 2 shows Unit price 1 00 Item Quantity 1 Dept 73 Payment Cash 1 00 1 DEPT073 1 00 TL 1 00 CASH 1 00 Unit price 13 00 Item Quantity 1 Dept 31 Payment Cash 13 00 Unit price Department No 1 DEPT031 13 00 TL 13 00 CASH 13 00 12 DEPT001 12 00 TL 12 00 CASH 20 00...

Page 33: ...tch X REG OFF RF PGM Z X2 Z2 PGM Description Choice Program code High amount limit for entering unit price manually Significant numbers D6 D1 6 1s 6 6 6 6 s Unit price Different setting Same setting Mode switch Appropriate key X REG OFF RF PGM Z X2 Z2 PGM To program the tax calculation status for each department Tax calculation status This specification defines which tax table should be used for a...

Page 34: ...Item 2 Dept 4 Taxable 2 preset Payment Cash 20 00 Unit price 1 00 preset Item Quantity 1 Dept 2 Payment Cash 1 00 Unit price 1 05 Quantity 1 Item Dept 3 Max amount 10 00 preset Payment Cash 2 00 ERROR ALARM Exceeding high amount 5 DEPT003 T1 10 00 1 DEPT004 T2 2 00 TA1 10 00 TX1 0 40 TA2 2 00 TX2 0 20 TL 12 60 CASH 20 00 CG 7 40 1 DEPT002 1 00 TL 1 00 CASH 1 00 Department No unit price Tax status ...

Page 35: ...wPLU Same setting Mode switch X REG OFF RF PGM Z X2 Z2 PGM Press key repeatedly until the status you want to program is appeared on the display T S1 00 RPT AMOUNT T1 T2 T3 T4 TOTAL CHANGE T S2 00 RPT AMOUNT T1 T2 T3 T4 TOTAL CHANGE T S3 00 RPT AMOUNT T1 T2 T3 T4 TOTAL CHANGE To program tax calculation status for each PLU 6 1s 6 PLU No 6 6 a 6 s Unit price To new not sequencial PLU Different settin...

Page 36: ...20 F Unit price 2 50 preset Item Quantity 1 PLU 14 Payment Cash 3 00 Unit price 2 50 preset Item Quantity 3 PLU 14 Payment Cash 10 00 Unit price 2 00 preset Item Quantity 10 PLU 7 Payment Cash 20 00 PLU No unit price 1 PLU0014 2 50 TL 2 50 CASH 3 00 CG 0 50 1 PLU0014 2 50 1 PLU0014 2 50 1 PLU0014 2 50 TL 7 50 CASH 10 00 CG 2 50 10 PLU0007 20 00 TL 20 00 CASH 20 00 CG 0 00 Quantity result Quantity ...

Page 37: ...Unit price 13 00 Item 2 Quantity 2 PLU 31 Payment Cash 60 00 Unit price Repeat 1 PLU0030 32 80 1 PLU0031 13 00 1 PLU0031 13 00 TL 58 80 CASH 60 00 CG 1 20 Open PLU OPERATION RECEIPT 30 3280 31 13 s 60 F Before registering an open PLU it is necessary to preset it as an open PLU ...

Page 38: ...ration on the last item registered the tax calculation for discount amount is performed in accordance with the tax status programmed for that item Whenever you perform a discount operation on a subtotal amount the tax calculation for the subtotal amount is performed in accordance with the tax status programmed for the p key Preparing and using discounts This section describes how to prepare and re...

Page 39: ...ypes of registration Reduction for items and subtotal OPERATION RECEIPT 5 25m 45 m s 75m 10 F You can manually input reduction values up to 7 digits long If you want to subtract the reduction amount from the department or PLU totalizer program Net totaling Reduces the last amount registered by the value input Dept 1 5 00 Item 1 Quantity 1 Taxable 1 preset Reduction Amount 0 25 PLU 45 6 00 preset I...

Page 40: ...eck 20 00 1 DEPT001 11 00 NS 1234 TL 11 00 CHECK 20 00 CG 9 00 Reference No X REG OFF RF PGM Z X2 Z2 OP PGM Mode switch Mixed tender cash and check OPERATION RECEIPT 55 s 30 k 25 F Charge OPERATION RECEIPT 15 s h If h is not allocated on the keyboard key allocation is necessary Credit OPERATION RECEIPT 10 s c If c is not allocated on the keyboard key allocation is necessary Dept 3 10 00 Item Quant...

Page 41: ...he result is shown on the display 1 Press the P key if you enter the payment in the sub currency 1 Press the a key to finalize the transaction The change amount is shown in the programmed currency 00l RPT T1 T2 T3 T4 TOTAL CHANGE 00l RPT T1 T2 T3 T4 TOTAL CHANGE 00l RPT T1 T2 T3 T4 TOTAL CHANGE 00l RPT T1 T2 T3 T4 TOTAL CHANGE 00 RPT T1 T2 T3 T4 TOTAL CHANGE 1 DEPT001 6 00 TL 6 00 12 00 EURO money...

Page 42: ...ister goods returned by customers OPERATION RECEIPT 235 2 1 R 235 R 1 s F Dept 1 2 35 Item 1 Quantity 1 Dept 2 2 00 Item 2 Quantity 1 PLU 1 1 20 preset Item 3 Quantity 1 Returned Dept 1 2 35 Item 1 Quantity 1 Returned PLU 1 1 20 preset Item 3 Quantity 1 Payment Cash 2 00 Press R before the item you want to return 1 DEPT001 2 35 1 DEPT002 2 00 1 PLU0001 1 20 RF 1 DEPT001 2 35 RF 1 PLU0001 1 20 TL 2...

Page 43: ...gister money paid out from the register This registration must be performed out of a sale OPERATION RECEIPT 150P Amount can be up to 8 digits No sale registration You can use the following procedure to open the drawer without registering a sale This operation must be performed out of a sale OPERATION RECEIPT N Received amount 700 00 Paid out amount 1 50 RC 700 00 PD 1 50 X REG OFF RF PGM Z X2 Z2 O...

Page 44: ...To cancel all items in a transaction To correct an item you input but not yet registered OPERATION RECEIPT 2 C 1 12X C 11X 2 2 C 3 15 6 C 15 10 s 10 C 15 F h Enter PLU No again Correction of unit price Correction of quantity Correction of PLU No Correction of open PLU unit price Correction of partial tender amount 1 DEPT001 1 00 11 DEPT002 22 00 1 PLU0003 1 30 1 PLU0015 10 00 TL 34 30 CASH 15 00 C...

Page 45: ...iscount Correction of refund item Correction of partial tender Corrected items are not printed on receipt in case of programming Buffered receipt printing 1 DEPT001 1 00 1 DEPT002 2 00 1 DEPT002 2 00 CORR 2 00 1 PLU0002 2 00 CORR 2 00 1 PLU0005 1 50 1 PLU0015 6 00 CORR 6 00 1 PLU0015 10 00 8 DEPT004 32 00 CORR 32 00 6 DEPT004 24 00 ST 38 50 50 19 25 CORR 19 25 ST 38 50 5 1 93 RF 1 DEPT 2 00 CORR 2...

Page 46: ...rations and Setups 46 E To cancel all items in a transaction OPERATION RECEIPT 1 2 3 4 s e Pressing s key is necessary to cancel the transaction 1 DEPT001 1 00 1 DEPT002 2 00 1 DEPT003 3 00 1 DEPT004 4 00 CANCEL ...

Page 47: ...n drawer 1 2 Credit in drawer 2 2 Credit in drawer 3 2 Credit in drawer 4 2 Refund mode 2 Number of customer 2 Average sales per customer 2 Discount total 2 Refund key 2 Rounding total 2 Cancellation 2 Z 03 06 2008 17 00 0001 000231 Z DAILY Z DEPT 0001 0001015 DEPT001 203 25 1 108 54 DEPT002 183 1 362 26 DEPT008 5 17 22 TL 421 25 2 872 28 Z FIX 0001 0001011 GROSS 981 25 6 574 40 NET No 111 7 057 1...

Page 48: ...N RECEIPT Signing clerk 1 on 1 6 o Signing clerk 2 on 2 6 o If you do not want the clerk number to be shown on the display press o before entering the number Clerk sign off OPERATION Signing clerk off Å except PGM mode The current clerk is also signed off whenever you set the mode switch to OFF position Important The error code E008 appears on the display whenever you try to perform a registration...

Page 49: ... Dept 1 1 00 Item 2 Quantity 1 Status S I S Payment Cash 3 00 3 DEPT001 3 00 TL 3 00 CASH 3 00 1 DEPT003 2 00 1 DEPT001 1 00 TL 3 00 CASH 3 00 Single item cash sales A department key or PLU programmed with single item sale status finalizes the transaction as soon as it is registered The single item sales function can only be used for cash sales Example 1 OPERATION RECEIPT 1 Dept 1 1 00 Item Quanti...

Page 50: ...inalize keys cannot be used OPERATION DISPLAY RECEIPT 5 Enter the unit price and press the applicable department key 5 Enter the next unit price and press the applicable department key 5 Press E and s without en tering a numeric value This op eration converts the subtotal in cluding tax dollar value into yen byapplyingapre programmedex change rate The result is shown on the display and printed on ...

Page 51: ... shown on the display and printed on the receipt journal by programming 5 Enter the partial amount tendered in yen and press E This operation converts the en tered yen amount into dollars by applying a pre programmed ex change rate The result is shown on the display 5 Press a to specify cash tender for the yen partial tender Note that you do not need to reenter the dollar amount Theregisterautomat...

Page 52: ...essary Dept 1 3 00 Item 1 Quantity 2 Coupon 0 50 2 Dept 3 4 00 Item 2 Quantity 1 Coupon 1 00 Payment Cash 8 00 2 DEPT001 6 00 COUPON 1 00 1 DEPT003 4 00 COUPON 1 00 TL 8 00 CASH 8 00 Premium Example OPERATION RECEIPT 1 10U 3X 2 s U F If U is not allocated on the keyboard key allocation is necessary Dept 1 1 00 Item 1 Quantity 1 Premium 10 Dept 1 2 00 Item 2 Quantity 3 Subtotal Premium 15 Payment C...

Page 53: ... 90 TX2 0 10 TL 3 00 CASH 3 00 Age verification This function is used to prohibit the item registration for the person whose age is under the programmed value Example OPERATION RECEIPT 1 0503 1988B 1 2 F If B is not allocated on the keyboard key allocation is necessary AGE AGE 05 03 1988 1 DEPT001 1 00 TL 1 00 CASH 1 00 Dept 1 1 00 Item 1 Quantity 1 Age limit 18 Dept 3 2 00 Item 2 Quantity 1 Age l...

Page 54: ...ct one of these options by programming Either of the following two operations can be used to correct input of a wrong check number NEW CHECK Re input the correct check number or cancel the original check number issue a receipt and then re input the correct check number OLD CHECK NEW OLD Temporary finalize the original check number issue a receipt and then re input the correct check number Opening ...

Page 55: ...130 00 CASH 130 00 CG 20 00 New old check key operation Example 1 When a check number is input and NEW OLD is pressed the key works as a new check key function if there is no matching check number in the check tracking memory OPERATION RECEIPT 3456Z 10 20 S Example 2 When a check number is input and NEW OLD is pressed the key works as an old check key if there is matching check number in the check...

Page 56: ...check Check 1234 Dept 1 10 00 Item 1 Quantity 1 Dept 2 20 00 Item 2 Quantity 1 Check No 1234 Check No 3456 CHECK No 1234 1 DEPT001 10 00 1 DEPT002 20 00 SRVC TL 30 00 Registration for check number 3456 OPERATION RECEIPT 3456N 30 S Registration for check number 1234 OPERATION RECEIPT 1234O 3456B S If B is not allocated on the keyboard key allocation is necessary CT 1 CHECK No 1234 ST 30 00 ADD CHK ...

Page 57: ...MALL SIZE TL 56 00 CASH 56 00 Inputting the number of customers Example OPERATION RECEIPT 2B 15 5 s F If B is not allocated on the keyboard key allocation is necessary Unit price 15 00 Item 1 Dept 1 Unit price 5 00 Item 2 Dept 2 Customer Number 2 Payment Cash 20 00 CST CT 2 1 DEPT001 15 00 1 DEPT002 5 00 TL 20 00 CASH 20 00 Flat PLU You can use the flat PLUs to register items The procedure to regi...

Page 58: ...rammed to allow use of the clerk interrupt function You cannot use the clerk interrupt function on a register set up to function as part of a check tracking system In the REG and RF modes clerks can be change while a transaction is in progress making it possible for multiple clerks to simultaneously perform registrations using a single register For example if clerk 1 is interrupted while registeri...

Page 59: ...10 60 Registering main PLU Main item PLU 20 20 00 PLU 21 0 00 Preparation PLU 22 0 00 PLU 23 0 00 Payment Cash 20 00 1 PLU0001 10 00 PLU0011 0 10 PLU0012 0 20 PLU0013 0 30 TL 10 60 CASH 10 60 1 PLU0020 20 00 PLU0021 PLU0022 PLU0023 TL 20 00 CASH 20 00 Set menu When you register a set menu its total amount is added to the PLU totalizer and counter The price of each set menu item is also added to ea...

Page 60: ...RECEIPT 5A If A is not allocated on the keyboard key allocation is necessary Arrangement 1 PLU 1 8 00 Item 1 Quantity 1 PLU 2 5 00 Item 2 Quantity 1 Payment Cash 13 00 Arrangement 5 Dept 1 1 00 Item 1 Quantity 1 Dept 2 2 00 Item 2 Quantity 1 Payment Cash 3 00 1 PLU0001 8 00 1 PLU0002 5 00 TL 13 00 CASH 13 00 1 DEPT001 1 00 1 DEPT002 2 00 TL 3 00 CASH 3 00 Tips OPERATION RECEIPT 3 5 s 80B 10 F If B...

Page 61: ...0 Press G before the item you want to return 1 DEPT001 2 35 1 DEPT002 2 00 1 PLU0001 1 20 VOID 1 DEPT001 2 35 VOID 1 PLU0001 1 20 TL 2 00 CASH 2 00 Addition OPERATION RECEIPT 1 10B 3X 2 3X B F Dept 1 1 00 Item 1 Quantity 1 Addition 0 10 Dept 1 2 00 Item 2 Quantity 3 Addition 3 0 20 Payment Cash 7 70 1 DEPT001 1 00 0 10 3 DEPT001 6 00 0 60 TL 7 70 CASH 7 70 If G is not allocated on the keyboard key...

Page 62: ...LU descriptors in the list 1 Turn to the PGM mode 2 Enter 07 and press the key 3 Select the item name and follow these steps in the list How to choose and set the preset receipt message and graphic logo in the list 1 Turn to the PGM mode 2 Enter 08 and press the key Programming procedure and Preset message list is issued 3 Follow these steps in the list Preset message and graphic print sample New ...

Page 63: ...ers In this section the method to enter descriptors or messages characters to the cash register during programming is described Characters are specified by character keyboard or by multi tapping method In the first half of this section the usage of character keyboard is described In the latter half inputting method by multi tapping is described Using character keyboard A B C D E F G H I J K L M N ...

Page 64: ...ars the last input character much like a back space key 6 Program end key Terminates the character programming 7 Character enter key Registers the programmed characters 8 Right cursor key Move the cursor to the right by one to enter a character on the same tapping key Example Input C L A S S a enter DBL 888 555 DBL 8 1111 1111 Space 8888 Key Text 7 _ x space A B C a b c 8 Ä Å Æ Á Â À Ã Ç â ä à å æ...

Page 65: ...To the next PLU a See Entering characters section on page 63 64 PLU No Contents Initial character Yours 0001 PLU0001 0002 PLU0002 0003 PLU0003 0004 PLU0004 0005 PLU0005 0006 PLU0006 0007 PLU0007 0008 PLU0008 0009 PLU0009 0010 PLU0010 0011 PLU0011 0012 PLU0012 0013 PLU0013 0014 PLU0014 0015 PLU0015 0016 PLU0016 0017 PLU0017 0018 PLU0018 0019 PLU0019 0020 PLU0020 0021 PLU0021 0022 PLU0022 0023 PLU00...

Page 66: ...Yours PLU0001 PLU0002 PLU0003 PLU0004 PLU0005 PLU0006 PLU0007 PLU0001 PLU0002 PLU0003 PLU0004 PLU0005 PLU0006 PLU0007 Function key Department key Flat PLU key 1 Appropriate key In case of shifting department press DEPT SHIFT key first In case of shifting flat PLU press MENU key first Contents Initial character Yours Cash amount tendered Check New balance New check Old check Received on account Pai...

Page 67: ... character Yours No 01 02 03 04 05 C01 C02 C03 C04 C05 Memory Contents Initial character Yours No 01 02 03 04 05 06 07 08 09 10 11 12 25 40 41 42 1st line of logo message 2nd line of logo message 3rd line of logo message 4th line of logo message 1st line of commercial message 2nd line of commercial message 3rd line of commercial message 4th line of commercial message 1st line of bottom message 2nd...

Page 68: ... Credit 2 in drawer Credit 3 in drawer Credit 4 in drawer Cash in drawer for sub currency Charge in drawer for sub currency Check in drawer for sub currency Refund mode total Customer count Average sales per customer Clerk commision 1 total Clerk commision 2 total Foreign currency cash in drawer Foreign currency check in drawer Reduction Coupon Item return Rounding for sub currency Rounding Cancel...

Page 69: ...ation display 2 multiplication 6 not used 6 taxable symbol 1 3 each for tax 1 tax 2 tax 3 tax 4 taxable symbol 3 3 each for tax 1 2 tax 1 3 not used not used tax 2 3 foreign currency 2 each not used 8 mode symbol 1 4 each REG1 2 RF not used mode symbol 2 4 each PGM Daily X Daily Z Periodic mode symbol 3 4 each not used PGM read decimal amount q ty separator main sub 1 each not used 3 square 7 A M ...

Page 70: ...A B rounding Last 1 digit of ST CA CG Result 0 4 5 0 5 6 9 10 Singaporean rounding Last 1 digit of item REG Result 0 2 0 3 7 5 8 9 10 Finnish rounding Last 2 digit of ST CA CG Result 0 2 0 3 7 5 8 9 10 Danish rounding Last 2 digit of ST CA CG Result 00 12 00 13 37 25 38 62 50 63 87 75 88 99 100 Norwegian rounding Last 1 digit of ST Result 00 24 0 25 74 50 75 99 100 IF 1 rounding Last 1 digit of ST...

Page 71: ...2 D1 S a b D4 Description Choice Program code Initial value Follow the taxable status and commission status of previous item when operation is performed Force a money declaration before read reset operation Force to press s before finalization Allow credit balance while finalization Allow multiple refund operation Affect the result of to the item Net totalling Include commission in net total Clear...

Page 72: ...al report RF Print the net number of customers on fixed total report CUST Print the average sales per customer on fixed total report AVER Always 0 Print commission 1 total on fixed total report C 1 Print commission 2 total on fixed total report C 2 Print foreign currency cash in drawer and check in drawer totals on fixed total report CECA1 2 CECK1 2 Print MINUS COUPON and mix match operation net t...

Page 73: ...tal report 1 Comma 0 2 Period 1 Always 0000 a b a b D8 a b D7 D6 a b D5 D4 D3 D2 D1 Significant number 0 9 1 0 2 1 1 0 2 4 Significant number 0 9 1 0 2 1 1 0 2 4 D8 a b D7 D6 a b D5 D4 D3 D2 D1 Description Choice Program code Initial value Zero skip department report Zero skip clerk report Zero skip transaction report Zero skip PLU report Zero skip hourly report Zero skip group report Always 0 Pro...

Page 74: ...lidation Always 00 a b D6 D5 a b D4 D3 D2 D1 No 0 Yes 4 Yes 0 No 1 Yes 0 No 2 No 0 Yes 4 D6 D5 a b D4 D3 D2 D1 Address code 16 print control for grand total Description Choice Program code Initial value Print consecutive number range of the day on daily fixed total report Always 00000 Print grand total on daily sales reset report D7 D6 D2 D1 No 0 Yes 1 Yes 0 No 1 D7 D6 D2 D1 Address code 17 print ...

Page 75: ...k number compulsory Number of customer compulsory Guest receipt compulsory at finalization Always 0 Tax calculation by new balance Calculation result is not saved into totalizer Always 0000 a b c D7 D6 D5 D4 D3 D2 D1 No 0 Yes 1 No 0 Yes 2 No 0 Yes 4 No 0 Yes 1 a b c D7 D6 D5 D4 D3 D2 D1 a b c Description Choice Program code Initial value Print graphic type logo If select No character type logo is ...

Page 76: ...y by double sized letter Selection of the currency of change 1 Main currency 2 Sub currency Print the cash in drawer of sub currency on fixed total reports If the cash in drawer of main currency is skipped this line is also skipped Display symbol of sub currency 1 e Euro 2 l Local The currency to restrict to 00 25 50 75 on last two digits for amount tendered 1 Main currency 2 Sub currency It is ne...

Page 77: ...D4 D3 D2 D1 Available 0 Not available 1 D4 D3 D2 D1 Description Choice Program code Initial value Print preset receipt message and graphic Print preset receipt message and graphic 1 at the bottom of the receipt 2 at the top of the receipt Journal compressed print print by half height characters Always 000 a b D5 D4 D3 D2 D1 No 0 Yes 1 1 0 2 2 Yes 0 No 1 a b D5 D4 D3 D2 D1 a b ...

Page 78: ...tion Choice Program code Initial value Age limitation 00 means no limitation Single item control Normal receipt 0 Single item receipt 3 Always 0 Normal condiment preparation Only for PLU Flat PLU Normal item 0 Condiment 1 Preparation 2 Always 0 Taxable status See page 81 Enable 0 unit price Enable negative price Hash Always 0 Low digit limitation LDL for manually entered unit price Open PLU only f...

Page 79: ... 6 66s 6 6 6 6s PGM Mode switch To another key Program data Appropriate key Same program Address code In case of shifting department press DEPT SHIFT key first In case of shifting flat PLU press MENU SHIFT key first 6 3s 6 66s 6 6 6 a 6 s PGM Mode switch To a new not sequential PLU Program data Same program Address code PLU No Different program to the next PLU ...

Page 80: ...r PLU D7 D6 D5 D4 D3 D2 D1 Significant numbers Significant numbers Other address code Address code Description Choice Program code Single item control Normal receipt 0 Single item receipt 3 Normal condiment preparation Normal item 0 Condiment 1 Preparation 2 Taxable status See page 81 Enable 0 unit price Enable negative price Hash Low digit limitation LDL for manually entered unit price Open PLU O...

Page 81: ...estriction to 00 25 50 75 on last two digits for amount tendered Only for CASH in Danish rounding Always 00 Prohibit entry of a partial payment Prohibit the entry of the amount tendered Force entry of the amount tendered Print VAT breakdown 1 French food coupon Perform Finnish rounding High amount limit specification for subtotal and tendering amounts High amount limit specification for change amo...

Page 82: ...8 D7 D6 D5 D4 D3 a b D2 D1 No 0 Yes 2 Significant number No 0 Yes 1 No 0 Yes 2 Description Choice Program code Allow mode change or clerk change after non add registration as first transaction only for non add function Always 0000 Always 00 D7 D6 D5 D4 D3 D2 D1 Yes 0 No 1 NON ADD NON ADD NO SALE Description Choice Program code Taxable status See page 81 Allow credit balance CPN only Allow out of s...

Page 83: ...al 0 Comma 1 Comma 0 Decimal 4 MULTIPLICATION Description Choice Program code Multiplication procedure X only 1 Quantity Amount 2 Amount Quantity Rounding Round off 0 cut off 1 round up 2 Always 0000 D6 D5 D4 D3 D2 D1 1 0 2 1 Significant number Description Choice Program code Taxable status 00 01 04 00 means taxable 1 Always 000000 D8 D7 D6 D5 D4 D3 D2 D1 Significant numbers SUBTOTAL MERCHANDISE S...

Page 84: ...subtotal and tendering amounts Always 0 Specify credit in drawer total in the fixed totalizer a b c a b a b c D7 D6 a b D5 D4 D3 D2 D1 No 0 Yes 1 No 0 Yes 2 No 0 Yes 4 No 0 Yes 1 No 0 Yes 1 No 0 Yes 4 Maximum value 0 9 Number of zeros 0 9 Significant number 0 4 TEXT RECALL Description Choice Program code Order character file record number Always 0000 D6 D5 D4 D3 D2 D1 Significant numbers Descripti...

Page 85: ...Programming procedure Program Data 63s 6 07s6 6 a 6 s PGM Mode switch To a new not sequential clerk D10 D9 D2 D1 Record No To the next clerk Address code 68 Commission rate Description Choice Program code Commission rate 1 integer 00 99 Commission rate 1 decimal 00 99 Commission rate 2 integer 00 99 Commission rate 2 decimal 00 99 D8 D7 D6 D5 D4 D3 D2 D1 Significant numbers Significant numbers Sig...

Page 86: ...ems are treated as child PLU 2 Assigning set menu tables to parent PLU When a parent PLU is registered all child PLUs in the designated set menu table are registered Programming procedure Arrangement programming Programming procedure 63s 6 38s6 A6 a 6 6 6 A 6 s The same A should be pressed Vacant record search If you want to set an arrangement program to a new record vacant record search is possib...

Page 87: ...Manual tax 032 Refund 033 Error correct cancel 034 Void 035 Receipt 038 Content Function code Non add 040 Non add no sale 041 No sale 042 Customer number 043 Arrangement 044 Currency exchange 045 VAT 046 PLU 048 Price 049 Department 051 Tax shift 057 Flat PLU 063 Menu shift 064 Open 067 Clerk number 072 Subtotal 075 Receipt on off 076 Merchandise subtotal 080 Content Function code Multiplication 0...

Page 88: ...rwise you will not be able to distinguish between the sales data for different dates To print the individual department PLU read report This report shows sales for specific departments or PLUs OPERATION DISPLAY 1 Turn to X mode X REG OFF RF PGM Z X2 Z2 PGM Mode switch 2 Specify a department PLU flat PLU REPORT Specifying a department Specifying a PLU 1 10 Specifying a flat PLU 3 Press ST to exit t...

Page 89: ... cash in drawer in the memory and print the difference between these two amounts Note that if money declaration is required by programming you cannot skip this procedure To print open check read report OPERATION 1 Turn to X mode 2 Select open check report by the RC key 3 Press CASH key 4 a Press CASH key to issue all open check 4 b Enter check no and press NEW OLD key to issue indidual check repor...

Page 90: ...are the input with the cash in drawer in the memory and print the difference between these two amounts Note that if money declaration is required by programming you cannot skip this procedure To print open check reset report OPERATION 1 Turn to Z mode 2 Select open check report by the RC key 3 Press CASH key 4 a Enter check no and press NEW OLD key to issue indidual check report 4 b Enter clerk no...

Page 91: ...1015 DEPT001 38 8 13 257 53 DEPT002 183 1 362 26 TL 88 61 1 916 10 Z FIX 0001 0001011 DECLA 6 919 04 0 00 GROSS 981 25 6 574 40 NET No 111 7 057 14 CAID 6 919 04 CHID 139 04 CKID 859 85 CRID 1 709 85 CRID 2 0 00 CRID 3 0 00 CRID 4 0 00 RF No 3 10 22 CUST CT 111 AVRG 63 57 Report title Department report title reset counter Report code Department name No of items 2 Sales ratio amount 2 Total No of i...

Page 92: ...20 23 00 00 00 CT 1 GROSS 3 45 NET No 1 3 90 3 59 TL CT 280 GROSS 1 937 61 NET No 25 2 096 80 X PLU 0000014 PLU0001 17 0 53 17 00 0001 PLU0100 42 4 03 69 00 0100 TL 188 61 516 10 Read symbol report title Report code PLU name No of items Sales ratio PLU amount PLU code Total No of items Total amount Read symbol report title Report code Time range No of customers Gross sales amount No of receipt Sal...

Page 93: ... Group total amount Group report Open check report Report header title Report code Mode symbol date time Clerk descriptor Mc No consecutive No Table No No of customer Check No Subtotal amount Print BUSY if the check is currently opened No of open check Open check total Z OPEN CHECK 0001025 REG 03 04 2008 09 02 C01 0001 000004 TABLE No 123456 CT 12 CHECK No 123 250 00 REG 03 04 2008 09 02 C01 MC 01...

Page 94: ...dic 1 2 sales read reset reports These reports show sales breakdowns of sales by any two kinds of period you want OPERATION DISPLAY 1 Turn to X2 Z2 mode X REG OFF RF PGM Z X2 Z2 PGM Mode switch 2 Select report you want to get by the RC key 3 Press CASH to print report XZ NEXT RC PERIODIC 1X 00 RPT AMOUNT T1 T2 T3 T4 TOTAL CHANGE XZ NEXT RC PERIODIC 1Z 00 RPT AMOUNT T1 T2 T3 T4 TOTAL CHANGE XZ NEXT...

Page 95: ... 0001 0001111 GROSS 981 25 6 574 40 NET No 111 7 057 14 CAID 6 919 04 CHID 139 04 CKID 859 85 CRID 1 709 85 CRID 2 0 00 CRID 3 0 00 CRID 4 0 00 RF No 3 10 22 CUST CT 111 AVRG 63 57 DC 1 22 REF 2 42 ROUND 0 00 CANCEL No 2 12 97 TA1 2 369 69 TX1 128 86 TA2 2 172 96 TX2 217 33 Report title Department report title reset counter Report code Department Name No of items 1 Sales ratio amount 1 Total No of...

Page 96: ... 06 GROUP03 0003 06 0004 06 C01 0001 07 C02 0002 07 C03 0003 07 0004 07 GT 0001 20 No 0001 23 NoCT LB QT 0002 23 X BUSY 0003 23 Program read symbol Fix total character Transaction key character Department character Group character Clerk character GT character Special character FIX 0001 24 TRANS 0002 24 PLU 0003 24 0004 24 DAILY X 0001 29 PERIODIC 1X 0002 29 PERIODIC 2X 0003 29 0004 29 0001 32 YOUR...

Page 97: ...2 000 DEPT001 026 051 CASH 013 001 0002 38 0001 62 000000 00000000000000 0000000000 MC 01 0001 91 00000000 0001 98 00000000000000 0002 98 00000000000000 Clerk detail link program Arrangement program Rec file arrange no Key descriptor rec file Scheduler program I O parameter table P03 CASH 0001 02 00000000000000 CHECK 0002 02 00000000000000 PD 0003 02 00000000000000 DEPT001 0001 05 00000000000000 1...

Page 98: ...ERATION REPORT 1 Turn to PGM mode 2 Enter 6 and press ST key 3 Enter 304 and press ST key 4 Enter start rec and CA key 5 Enter end rec and CA key Program 3 mode symbol PLU range PLU descriptor rec file Address code 01 10 18 program Address code 11 program Address code 13 program Address code 15 program P03 0001 0010 PLU0001 0001 04 00000000000000 11 66 000000 13 66 0001 28 14 66 0 15 66 1234 56 PL...

Page 99: ...99 Advanced Operations and Setups E ...

Page 100: ...use New Check to open a new check using a number that is already used for an existing check in check tracking memory Attempt made to use Old Check reopen a new check using a number that is not used for an existing check in check tracking memory Attempt to finalize a transaction when balance is less than or equal to zero Error code Message Meaning Action Return the mode switch to its original setti...

Page 101: ...owed Arrangement file full Insert RAC Illegal Format File not found File already exist Scanning PLU direct maintenance batch maintenance file becomes full PLU code is not existed in the file Scanning PLU file full The designated item has already existed in the scanning PLU file The journal platen arm is opened The receipt platen arm is opened Attempt to register or CPN when the balance becomes neg...

Page 102: ...ver the cash register enter an error condition as soon as you switch it on The results of this check are required by service personnel so be sure to perform this check before you contact a CASIO representative for servicing Start Is register plugged in Is power on Do figures appear on the display Do keys function Does paper feed Plug in the power cord Set the mode switch to any position other than...

Page 103: ...er failure symbol is printed and any item that was being printed when the power failure occurred is reprinted in full Important Once receipt journal printing or printing of a report starts it can be stopped only by interruption of power to the cash register Troubleshooting When the L sign appears on the display About the low battery indicator The following shows the low battery indicator If this i...

Page 104: ...older Step 5 Remove the paper guide from the take up reel Step 6 Slide the printed journal from the take up reel Step 7 Open the platen arm Step 8 Remove the old paper roll from the cash register Step 9 Load new paper Go to the step 3 described on page 12 of this manual Step 1 Set the mode switch to the REG position and remove the printer cover To replace journal paper X REG OFF RF PGM Z X2 Z2 ...

Page 105: ...tails User Maintenance and Options Step 1 Set the mode switch to the REG position and remove the printer cover Step 2 Open the platen arm Step 3 Remove the old paper roll from the cash register Step 4 Load new paper Go to the step 3 described on page 11 of this manual To replace receipt paper X REG REG OFF OFF RF RF PGM PGM Z X2 Z2 User Maintenance and Options ...

Page 106: ...gan is printed automatically Journal Thermal alpha numeric system 24 digits Automatic take up roll winding Paper roll 58 W 80 D mm Paper thickness 0 06 0 085 mm Paper feed Separate for receipt and journal Print speed About 14 l s Listing capacity Amount 99999999 Quantity 9999 999 Tendered amount 9999999999 Percent 99 99 Tax rate 9999 9999 Numbers 9999999999999999 Chronological data Date print Auto...

Page 107: ...3 83 customer display 20 22 customer number 26 57 D daily sales X 20 daily sales X report 88 daily sales Z 20 daily sales Z report 47 88 daily X report 89 daily Z report 17 90 date 30 date set 13 delete key 63 64 department 25 26 31 66 78 79 88 department number 26 32 department report 47 department shift 26 32 descriptor 62 descriptors by list 62 discount 24 26 38 82 display 22 double size letter...

Page 108: ...port 94 periodic sales Z report 94 PGM mode 20 platen 11 PLU 24 27 35 78 79 88 PLU report 92 pop up display 20 21 post receipt 25 27 premium 25 27 52 82 preset graphic 28 62 76 preset message 28 62 76 preset price 34 preset tax status 34 price 24 27 print control 71 72 73 74 printer 20 printer cover 20 program backup 17 program end key 63 64 program key 20 program mode 20 program report 96 R rate ...

Page 109: ... 35 38 39 tax system 70 tax table 14 taxable status 81 text recall 27 57 69 84 thermal paper 11 time 30 time set 13 tip 27 60 training clerk 84 U unit price 31 33 35 V VAT 25 27 53 void 27 61 W watermark 16 X X mode 20 88 X2 Z2 mode 20 94 Z Z mode 20 88 zero skip 73 zero unit price 78 81 ...

Page 110: ...CASIO COMPUTER CO LTD 6 2 Hon machi 1 chome Shibuya ku Tokyo 151 8543 Japan MO0712 A Printed in Indonesia Printed on recycled paper SE S2000 E ...

Reviews: