Casio QW-3195 Service Manual & Parts List Download Page 3

– 1 –

SPECIFICATIONS: MODULE QW-3195

11 

Item

Detail

Battery

CTL1616 (Storage battery)

Note:  Use CTL1616 only1 Other storage battery or CR1616 can cause  
 

damage to the watch1

Battery life

Approx. 10 months

Current consumption

1.22 µA maximum
See page 7

Alarm system

Piezo plate on Cover/Back

Accuracy

±15 sec./month

Accuracy setting system Trimmer capacitor
Accuracy checking

See page 7

Functions

 

Shock resistant (G-SHOCK)

 

Electro-luminescent backlight

  Full auto EL light, afterglow

 

Solar powered

  World time
  31 time zones (48 coordinated universal time), city code display, day-

light saving on/off

 

1/100-second stopwatch

  Measuring capacity: 23:59’59.99”
  Measuring modes: Elapsed time, split time, 1st-2nd place times

 

Countdown timer

  Measuring unit: 1 second
  Input range: 1 minutes to 24 hours (1-minute increments and 1-hour incre-

ments)

 

Daily alarms

  5 independent daily alarms (4 one-time alarms and 1 snooze alarm)

 

Hourly time signal

 

Battery power indicator

 

Power Saving (turns off the display when the watch is left in the dark)

 

Full auto-calendar (to year 2099)

 

12/24-hour format

 

Button operation tone on/off

 

Regular timekeeping: Hour, minute, second, pm, month, date, day

 

Time Calibration Signal Reception

 

Auto receive 6 times a day (Remaining auto receives cancelled as soon as 

one issuccessful) (five times for the China signal); Manual receive

  Receivable Time Calibration Signals:
 

Mainflingen, Germany (Call Sign: DCF77, Frequency: 77.5 kHz);

 

Anthorn, England (Call Sign: MSF, Frequency: 60.0 kHz);

  Fort Collins, Colorado, the United States
 

(Call Sign: WWVB, Frequency: 60.0 kHz);

 

Fukushima, Japan (Call Sign: JJY, Frequency: 40.0 kHz);

 

Fukuoka/Saga, Japan (Call Sign: JJY, Frequency: 60.0 kHz);

 

Shangqiu City, Henan Province, China

 

(Call Sign: BPC, Frequency: 68.5 kHz)

Summary of Contents for QW-3195

Page 1: ...SERVICE MANUAL PARTS LIST WITHOUT PRICE QW 3195 MODULE NO REF NO S M 1097 NOV 2009 GW 2310 ...

Page 2: ... 3 3 EXPLODED VIEW MODULE QW 3195 4 4 PARTS LIST MODULE QW 3195 5 5 REPLACEMENT OF BATTERY MODULE QW 3195 6 6 DISASSEMBLY MODULE QW 3195 7 7 TESTING MODULE QW 3195 7 1 MEASURING CURRENT CONSUMPTION 7 7 2 ACCURACY CHECKING 7 7 3 SOLAR CELL PCB ASS Y CONTACT CHECKING 8 7 4 HOW TO CHECK TILT SENSOR 8 7 5 TIME CALIBRATION SIGNAL TEST 9 ...

Page 3: ...ange 1 minutes to 24 hours 1 minute increments and 1 hour incre ments Daily alarms 5 independent daily alarms 4 one time alarms and 1 snooze alarm Hourly time signal Battery power indicator Power Saving turns off the display when the watch is left in the dark Full auto calendar to year 2099 12 24 hour format Button operation tone on off Regular timekeeping Hour minute second pm month date day Time...

Page 4: ...x16y3 c 0 b 0 x16y2 x15y3 x15y1 x15y4 x15y0 x15y2 x14y3 x14y2 x14y0 x14y1 x14y4 x13y4 x13y1 x13y2 x13y0 x13y3 x12y2 x12y1 x12y0 x12y3 x12y4 x11y2 x11y1 x11y0 x11y3 x11y4 x10y1 x10y3 x10y4 x10y2 x10y0 x9y0 x9y4 x9y2 x9y3 x9y1 x8y1 x8y3 x8y2 x8y4 x8y0 x7y2 x7y4 x7y3 x7y1 x7y0 x6y1 x6y0 x6y4 x6y3 x6y2 x5y3 x5y1 x5y0 x5y4 x5y2 x4y3 x4y0 x4y4 x4y1 x4y2 x3y1 x3y2 x3y4 x3y3 x3y0 x2y2 x2y1 x2y0 x2y4 x2y3 ...

Page 5: ..._C1 VR2OUT GND AGC VDD VDD2 RPL PLL_C2 SHPR_C LPF_BB DET_C PEAK_C VCC SCUT VDD2 VCC VCC GND ANT1 KI4 GND VDD2 GND VDD2 VDD2 GND XTB VSC VSC VDD2 ANT2 LL1 VCH VDSP VC1 KI5 KI3 LL1 BD VDD2 LL1 GND LL1 GND L L GND GND GND GND GND KI5 GND ANT2 LPF2IP GND LPF2QN VR1OUT GND Short pad for switching modules KI11 GND Open KI12 GND Open Short pad for switching modules KI7 GND Open KI8 GND Open KI10 GND Open...

Page 6: ...DULE QW 3195 333 6 10300759 7 10323019 10 10321674 2 10332415 8 10323023 14 10054634 5 10168959 1 10330011 8 10323023 3 10323021 13 10080941 11 72300511 PCB Ass y 9 10065664 4 10291127 Battery Storage CTL1616 12 72301036 ...

Page 7: ...nd stocked appropriately in consideration of your parts usage anre repair usage for similar models MAIN PARTS Item Code No Parts Name Specification Q TY R 1 10344144 MODULE WITHOUT MOVEMENT QW 3195AT 01TK 1 A 1 10330011 PCB ASS Y RJQ546770 001V01TK 1 A 2 10332415 LCD K3195 01THP 1 A MINOR PARTS Item Code No Parts Name Specification Q TY R 1 3 10323021 EL EL 3179 A 00 1 C 4 10291127 BATTERY STORAGE...

Page 8: ...ime Keeping Mode After AC Date Saturday January 1 2005 Time 12 00 00 AM Home City Code TYO Home Time DST AUTO WT City Code DST Auto Receive Home Time Auto Receive ON Time Format 12 hour format Power saving ON Auto Light OFF Battery Level HIGH Factory default World Time WT City Code UTC Time Format 12 hour format DST All Cities OFF Alarm Alarm Time MA5 g 12 00 AM Time 12 00 00 AM Home City Code TYO...

Page 9: ...r after switching the module to ACCURACY CHECKING MODE The operations are shown below SWITCHING TO ACCURACY CHECKING MODE 111 While pressing the A button press D and C buttons at the normal time keeping mode Then all the segments are displayed and the LCD drive signals are changed to the static drive signal of 32 Hz so that you can check the ac curacy with the quartz timer CANCELLATION OF THE ACCU...

Page 10: ...heck that 8888 appears on the display indicating that light is insufficient Once 8888 appears the display remains the same even after the watch face is exposed to light Figure 3 To exit from TEST mode press 333 D button HOW TO CHECK TILT SENSOR 77777 While pressing 111 A button press C and B buttons at the normal timekeeping mode Check the display indicates as figure 4 222 Tilt the watch in the wa...

Page 11: ...alibration signal use the normal mode To check the signal using TEM cell perform the inspection in the Test Mode MANUAL AUTO Reception 7777777 For details of MANUAL and AUTO reception modes refer to the Operation Guide MANUAL Reception While in Normal Time Keeping mode hold down D for 2 seconds to start receiving signals manually Reception OK The time is adjusted and GET appears on the display for...

Page 12: ...rs to leave the Test mode and return to Timekeeping mode J40 J60 U60 G77 L60 D02 40kHz JJY40 60kHz JJY60 60kHz WWVB 77 5kHz DCF 60kHz MSF the factory test in China BPC BPC2 D02 BPC1 B01 BPC3 G03 BPC4 T04 JJY40 J40 JJY60 J60 WWVB U60 DCF77 G77 MSF L60 LCD TYO NYC PAR LON HKG D C B JJY40 JJY60 WWVB DCF77 MSF BPC1 BPC2 BPC3 BPC4 OK J40 OK J60 OK U60 OK G77 OK L60 OK B01 OK D02 OK G03 OK T04 OK NG J40...

Page 13: ...CASIO COMPUTER CO LTD Overseas Service Division 6 2 Hon machi 1 Chome Shibuya ku Tokyo 151 8543 Japan ...