— 4 —
ADJUSTMENT
1. Unit Adjustment
Contents of the adjustment
(1) Color parameters loading
(2) Scratch compensation
(3) Flash adjustment
(4) Flash function check
(5) Current consumption check
(6) Clock reset
(7) Other test modes
Necessary equipments
(1) IBM PC/AT compatible computer
(2) Computer link cable
(3) Digital oscilloscope
(4) Stabilized power supply
(5) Ammeter
1-1. Color parameters loading
Perform the following procedures when you replaced Camera Unit.
(1) Set the QV-780 in “PLAY” mode.
(2) Connect the camera and a computer with a link cable.
(3) Execute the following program on MS-DOS system.
PON776.EXE (for COM port 1)
(4) Loading is done successfully when computer monitor shows a message stating that loading is
completed.
Note: After the loading, also perform the following Scratch compensation and Flash adjustment.
Digital terminal
To RS-232C
connector
When the loading is completed normally
.
When the loading is failed (example)