— 5 —
✽
Gray paper should be larger than 1.5 m (H)
×
2.0 m (W).
1-4. Strobe check
Checking if there is a false operation triggered by a distorted waveform when using strobe.
• Set strobe adjustment.
• Input DC in 6.0
±
0.1 V.
(1) Set QV-770 to “REC” mode.
(2) Monitor the trigger waveform on digital oscilloscope and check the display.
(3) Automatically recharged after shooting picture.
Make sure that the DC in 6.0 V current does not exceed 1.2 A.
(4) Set QV-770 to “PLAY” mode and check the display.
Should not be white or too dark.
✽
If it is NG, make sure the wiring of strobe circuit.
Strobe icon
LCD
1 meter
Gray paper
DC6.0
±
0.1V
Voltage
Regulator
A
Ammeter
Digital oscilloscope
TIME: 1.0
µ
sec/DIV
VOLTS: 1V/DIV (AC)
• Put oscilloscope probe on Camera unit.
• Earth of the probe should be hooked as shown above.
Summary of Contents for QV-770
Page 1: ...R QV 770 APR 1998 without price KX 773...
Page 16: ...14 2 Adjustment of PCB DA Adjustment points of PCB K773 DA...
Page 28: ...26 EXPLODED VIEW 38 35 S3 S3 39 27 32 S3 38 33 38 S3 S2 37 33 34 36 S1 29 40 30 28 31...
Page 35: ...33 PRINTED CIRCUIT BOARDS D board PCB K773A DA...
Page 36: ...34 L board PCB K773A LA...
Page 37: ...35 L board PCB K773A LB CA board PCB K773A CA...
Page 38: ...36 K board PCB K773A KA PCB K773A KB...
Page 39: ...37 SCHEMATIC DIAGRAMS DA CIR K0773AAA...
Page 40: ...38 LA CIR K0773AAA...
Page 41: ...39 LB CIR ZK0773AAA...
Page 42: ...40 KX CIR ZK0773AAA...
Page 43: ...41 KA CIR K0773AAA...
Page 44: ...42 KB CIR K0773AAA...