— 46 —
[ 21 ] Time setting / [ 22 ] Time display
[Function]
This sets the time and date.
When setting the time, the time and date will be displayed without inputting the fixed value.
[Operation]
* Date and time setting
Operation :
x1
x2
x3
x4
x5
x6
0
a
7
0
ST
a: 0: time setting x1/x2: time, x3/x4: minutes, x5/x6: second
1: time setting x1/x2: year, x3/x4: month, x5/x6: day
The test will be done one time.
* Date and time display
Operation :
7
0
ST
To stop the operation, press "ESC" key.
[LCD]
Each data will be printed only when setting the date and time.
DATE/TIME 70
DATE/TIME YY/MM/DD
HH:MM-SS
END
70
DATE/TIME YYMMDD0170
DATE
YY/MM/DD
END
YYMMDD0170
[PRINT]
[ 23 ] Drawer open test
[Function]
This test will check the drawer open function. The test ends by the judgment of the operator either
by OK or NG only when the one time check is selected.
[Operation]
Operation :
x
n
0
9
1
ST
x: 0 = All drawers open (can be omitted), 1 = Drawer 1 open, 2 = Drawer 2 open
n: 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press "ESC" key)
* When the continuous check is selected, the drawer opens every 2 seconds.
* The following "OK" or "NG" key can be used in case of one time check.
"OK" = 1, "NG" = 9
[LCD]
The status signal from the drawers appears in the status display position of the LCD.
In case of continuous check as well as when all drawers are open, the status appears after all the
drawers open.
DRW
xn091
DRW ALL
OK
END
xn091
DRW
xn091
DRW ALL
OK
END
xn091
[PRINT]
Summary of Contents for QT-6000
Page 79: ... 77 8 14 ETHERNET CONTROLLER IC28 LAN91C113 8 14 1 Pin Assignment 8 14 2 Block Diagram ...
Page 105: ... 103 11 PCB LAYOUT MAIN PCB E820 1R PCB TOP VIEW ...
Page 106: ... 104 MAIN PCB E820 1R PCB BOTTOM VIEW ...
Page 135: ... 133 EXPLODED VIEW QT 6060D 2 11 17 14 15 20 Sales Option 16 5 6 12 13 18 19 8 7 10 3 1 4 9 5 ...
Page 150: ... 148 18 DRAWER DL 3616 ...
Page 152: ... 150 19 DRAWER DL 3617 ...