CD ADJUSTMENT
Precautions
To prevent damage caused by static electricity, the following procedures for grounding is requir or repairing
the unit.
[Note] Remove the connection after installed.
1. Grounding for the human body
Be sure to put on a wrist-strap for grounding (with impedance lower than 10
6
Ω
) whose other end is
grounded. The strap works to drain away the static electricity build-up on the human body.
2. Grounding for the work table
Be sure to lay on the table a conductive sheet (with impedance lower than 10
6
Ω
) such as a sheet of
copper which is grounded.
3. As static electricity build-up on clothes is not drainded away, be careful not to let your clothes touch the
unit.
4. The short-pad on the pick-up PCB of a spare part is short-circuited for protection during shipment. To
open the short circuit, remove the soldering quickly with a soldering iron whose insulation resistance is
larger than 10M
Ω
after connection to a suitable APC circuit.
Equipment Required
*
Multi Meter
*
Oscilloscope
*
Compact Disc
*
Dummy Load 10 k
Ω
Pickup
Shorting tab
Desolder here
Pickup
1. Wrist-Strap
for grounding
1M
Ω
1M
Ω
2. Conductive Sheet
2
Summary of Contents for PZ-3100
Page 1: ... without price PZ 3100 PORTABLE CD PLAYER Model B USA Model C Europe INDEX ...
Page 5: ...3 BLOCK DIAGRAM ...
Page 13: ...11 PCB VIEWS CD AMP PCB Top View CD Door PCB Top View ...
Page 14: ...12 CD AMP PCB Bottom View ...
Page 15: ...13 WIRING DIAGRAMS ...
Page 16: ...14 IC LEAD IDENTIFICATION AND INTERNAL DIAGRAMS IC101 BA6894K ...
Page 17: ...15 IC102 CXA1992AR ...
Page 18: ...16 IC103 CXD2589Q ...
Page 19: ...17 IC104 CXP83416 127R ...
Page 20: ...18 IC106 SM5859AF TF ...
Page 21: ...19 IC107 KM44V1004CJ 6 ...
Page 22: ...IC109 IC110 NJM3414AM TE2 20 IC108 BA3574BFS ...
Page 24: ...22 CD Door PIck up ...
Page 32: ...13 1 13 2 13 3 13 4 13 5 13 6 13 7 30 CD Mechanism ...