background image

 

 

6

 

1. Product 

Overview 

1.1  Features at a Glance 

IT-9000 has been designed using the new concept of the Human-centered Design Processes and is 
capable of performing a wide variety of powerful functions. 
The following is a brief overview of the features available on the IT-9000 series handheld terminals. 
For further detail on the hardware specifications, refer to IT-9000 Series Hardware Manual. 
 

Outstanding development environment   

 

Microsoft

®

 Windows Mobile

®

 6.5 English Version as the built-in OS 

 

Visual Studio 2008 

 

Visual Studio 2005 

 

Various communication systems 

 

Built-in ultra-small WLAN module compatible with the IEEE802.11b/g standard 

 

Built-in WWAN module combines GSM, GPRS and EDGE modules with GPS receiver 

designed for use in transportation and logistics. 

 

High speed infrared communication with IrDA Version. 1.3 

 

Bluetooth

® 

Version 2.0 

 

Serial interface with USB version 1.1 (Host/Client) 

 

Small size, light weight 

 

Dimensions : Approx. 111.9(W) x 59.7 (D) x246.3 (H) mm 

 

Weight  

: Approx. 590 g 

 

Improved durability 

 

Impact resistance  

 

: 1.5 m in height * 

 

Dust/Water-splash proof  : IP67 level (compliant with IEC60529 International Standard) 

 

* The drop durability height is a measured value resulting from actual testing. It does not necessarily guarantee the 

product from damage.

 

Summary of Contents for IT-9000WM Series

Page 1: ...CASIO IT 9000WM Series Quick Start Guide Version 1 00 CASIO Computer Co Ltd Copyright 2012 All rights reserved March 2012...

Page 2: ...25 5 2 1 Installing ActiveSync for the First Time 25 5 2 2 If ActiveSync Is Already Installed 32 5 3 Windows Mobile Device Center via USB 34 5 4 Connection via WLAN 35 5 5 Connection via Ethernet Cra...

Page 3: ...puter Co Ltd in Tokyo Japan Information in this document is subject to change without advance notice CASIO Computer Co Ltd makes no representations or warranties with respect to the contents or use of...

Page 4: ...4 Editorial Record Manual Version no Date edited Page Content 1 00 March 2012 all Original version...

Page 5: ...tep by step instructions for installing and testing the CASIO Basic Development Kit BDK are included The purpose of this guide is to get you to the point where you can start development you should ref...

Page 6: ...2005 Various communication systems Built in ultra small WLAN module compatible with the IEEE802 11b g standard Built in WWAN module combines GSM GPRS and EDGE modules with GPS receiver designed for us...

Page 7: ...U Marvell PXA320 Application Processor runs at maximum 624 MHz Large capacity memory RAM 256 MB F ROM 256 MB SIM SAM ISO7816 IC Card standard 3V 1 8V SIM card supported Printer Method Dropin type Ther...

Page 8: ...the Printer Yes Yes PrinGDI Library Library that is used to control the built in Printer module in the print system Yes Yes MCR Library Library that is used to control the built in Magnetic Card Read...

Page 9: ...ribes individual functions in detail for NFC Library WANGPRS Library Manual Reference manual thatdescribes individual functions in detail for WANGPRS Library JPEG Library Manual Reference manual that...

Page 10: ...tware for the IT 9000 terminal Windows programming A good knowledge of one or more of the following Visual C Native or Manage code Visual Basic NET Visual C Browser based applications not covered in t...

Page 11: ...is for USA and Canada Table 2 2 List of the dedicated options Option Product Model no Remark USB Cradle HA L60IO HA L60IO CN Cradle Ethernet Cradle HA L62IO HA L62IO CN Battery Battery Pack HA G20BAT...

Page 12: ...12 External views of IT 9000 and dedicated options Figure 2 1...

Page 13: ...Vista or later OS Microsoft Windows Mobile Device Center 6 1 32 bits for Windows Vista http www microsoft com downloads details aspx familyid 46F72DF1 E46A 4A5F A791 09F 07AAA1914 displaylang en Wind...

Page 14: ...indows XP or Windows Server 2003 or via Windows Mobile Device Center for Windows Vista or later For connection method refer to Chapter 5 Connecting IT 9000 to PC 4 Setting up the Development Environme...

Page 15: ...name and password Enter your user name and password as issued by CASIO Notes If your PC runs in the Windows Vista or later OS first you must disable the User Account Control UAC by following the proc...

Page 16: ...e drive of PC the following menu screen appears automatically Figure 3 1 The version number in the figure may differ from that of your CD 2 Click Installation List in Figure 3 1 The installation scree...

Page 17: ...respectively C ProgramFiles CASIO MBSYS include Header file C ProgramFiles CASIO MBSYS lib ARMV4I Import library file 2 The Class library DLL file dll is installed in the following folder C Program F...

Page 18: ...ble for the below development platforms The installation of the Online Help is initiated in the Installation List Microsoft Visual Studio 2008 Microsoft Visual Studio 2005 After the installation is co...

Page 19: ...steps below to connect the power supply to IT 9000 using the dedicated AC adaptor Figure 4 1 1 Plug the AC adaptor into the AC adaptor jack where DCIN12V is printed on the back of the cradle 2 After c...

Page 20: ...r 1 on IT 9000 Orange Charging Red Standby due to battery pack error orthe surrounding temperature isout of the range charging begins when the temperature returns withinthecorrect range Green Charging...

Page 21: ...ed AC adaptor Figure 4 3 1 Plug the AC adaptor into the AC adaptor jack on the back of the Ethernet Cradle 2 After connecting the AC adaptor to the power cable plug in the plug of the power cable to a...

Page 22: ...Red Standby due to battery pack error or the surrounding temperature is out of range charging begins when the temperature is within the correct range Green Charging complete Notes Always remove IT 90...

Page 23: ...9F8141141 displaylang en Windows Mobile Device Center 6 1 or a later version for Windows 7 Windows Vista Windows Server 2008 or OS later installable Use the Windows Mobile Device Center to connect IT...

Page 24: ...le Device Center check the USB Connection settings on the terminal Follow the steps below 1 Navigate to Start Settings System tab USB Connection 2 Tap Connect Utility tab Figure 5 1 3 Confirm that Win...

Page 25: ...SB driver and ActiveSync in your development environment If you do not yet have the cradle driver on your PC download the USB driver files wceusbsh inf and wceusbsh sys from the CASIO web site and cop...

Page 26: ...9000 on the cradle and confirm that the green LED on the front of the cradle is lit If not be sure the IT 9000 is positioned firmly on the cradle 6 When the IT 9000 is mounted on the USB Cradle a dial...

Page 27: ...27 8 Then choose Install from a list or specific location Advanced radio button in the menu Figure 5 5 9 Click Next button Figure 5 6...

Page 28: ...28 10 Choose Windows CE USB Devices icon Figure 5 7 11 Click Have Disk button Figure 5 8 12 Click Browse button Select wceusbsh inf from the folder you created in step 6 Figure 5 9...

Page 29: ...nue Anyway button Figure 5 11 15 A menu might be displayed to prompt you to install wceusbsh sys This happens if wceusbsh sys is not in the same folder as wceusbsh inf Download this file from the CASI...

Page 30: ...30 16 Now the installation of the driver is finished Figure 5 12 17 Now go back to the ActiveSync Installation Wizard that you left on the desktop Click Next button Figure 5 13...

Page 31: ...remove IT 9000 from the Cradle Make sure not to short the feeding terminals Shorting circuit of the terminals may cause the defect Don t give any vibration or mechanical shock to the USB interface du...

Page 32: ...d on the PC You just need to let the PC recognize the IT 9000 and install the cradle driver as in steps 6 to 16 in Chapter 5 2 1 1 Navigate to File Connection Settings from the menu in ActiveSync See...

Page 33: ...the cradle and mount the device on the cradle again Caution When you turn the USB interface switch on off be sure to remove IT 9000 from the Cradle Make sure not to short the feeding terminals Shortin...

Page 34: ...Install WMDC to the PC if not installed 2 Connect the USB cable to the PC and the other end to the USB Cradle and also the AC adaptor to the USB Cradle 3 Make sure the selector switch on the back of t...

Page 35: ...rmines secondary DNS address WINS1 Determines primary WINS address WINS2 Determines secondary WINS address If any of the settings in Figure 5 is omitted the process described in the following table wi...

Page 36: ...has been deemed to be set Or if it has never been edited the key extracted fromthe ini file becomes effective asis If EAP PEAP radio button in Authentication field is selected tap the EAP Properties...

Page 37: ...k mark certificate is required Without check mark certificate isnot required Certificate is required 3 Tap WLAN tab Figure 5 22 Table 5 6 Field Radio Buttons Description Default On Enable power to the...

Page 38: ...to a network show popup Shows popup window when WLAN is not connected to a network With check mark enable the setting Enable AdHoc network setting Without check mark disable the setting Yes With check...

Page 39: ...on the terminal so that the setting takes effect Figure 5 243 6 Check to make sure that the connection has been established using the NetSearch utility and then navigating to the Ping function in ther...

Page 40: ...ernet cradle and the other end to the network hub 3 Make sure the selector switch on the back of the HA L62IO Ethernet cradle is set to the position LAN 4 Place IT 9000 in the cradle and navigate to S...

Page 41: ...following shows the steps to initiate this 1 Configure a network connection on IT 9000 2 Double tap My Device 3 Type xxxx where xxxx is the network name of the PC 4 A network logon dialog box will ap...

Page 42: ...e PC C Program Files Common Files Microsoft Shared CoreCon 1 0 Target wce400 armv4i The destination folder in IT 9000 Windows 2 Run ConmanClient2 exe on IT 9000 3 Set the device IP address in Visual S...

Page 43: ...43 9 Choose Windows Mobile 6 Professional Device in the list of Devices and click Connect button The screen in Figure 5 6 if appear indicates the success of connection establishment Figure 5 68...

Page 44: ...en_SAMLib ARMV4I CAB Yes Printer Library en_PrinterLib ARMV4I CAB Yes PrinGDI Library en_PrinGDILib ARMV4I CAB en_PrinGDILibWM ARMV4I CAB Yes MCR Library en_MCReadLib ARMV4I CAB en_MCReadLibWM ARMV4I...

Page 45: ...tiveSync 2 Open the application project for VB NET or C in Visual Studio 2005 3 Choose Windows Mobile 6 Professional Device in the pull down menu box Figure 6 1 4 Click the button shown in the red box...

Page 46: ...familyid 06111A3A A651 4745 88EF 3D4 8091A390B displaylang en Windows Mobile 6 Emulator Image for CASIO IT 9000 Mandatory IO Simulator Mandatory Notes To use Microsoft Device Emulator 3 0 follow the...

Page 47: ...ase check Run this program as an administrator of property from opening Explorer Ex Execute I O simulator in Windows Vista as administrator Figure 7 1 These program have installed the following locati...

Page 48: ...igure 7 3 I O Simulator Terminology of Emulator and Simulator The Emulator described in this reference manual is a software application that behaves in a very similar way to the actual device by imita...

Page 49: ...nput capability similar to that of the actual IT 9000 For instance a key on the emulated keyboard of IT 9000 on the screen see Figure 7 4 can be clicked with PC mouse as well as key input made directl...

Page 50: ...being mounted on the cradle Registration of bar code symbologies 1 Registration Click ADD1D or ADD2D button circled in red in Figure 7 5 to go into the bar code registration mode Figure 7 5 2 Bar cod...

Page 51: ...OK button to complete the bar code registration Figure 7 7 4 Completion of registration After completion of the bar codes registration the screen in Figure 7 8 shows a list of bar codes that have been...

Page 52: ...pears for editing the bar code and its information Figure 7 9 6 Deleting registered bar code content Highlight a bar code in the list of registered bar codes see Figure 7 8 and click the Del button Di...

Page 53: ...53 7 Barcode Reader By selecting a registered barcode it can be read into the emulator Select any barcode and then click the emulator trigger key...

Page 54: ...is checked a notification is issued that the connection between the IT 9000WM Device Emulator and cradle has been established This notification can be utilized by the application Low Battery If this b...

Page 55: ...9000WM Device Emulator LED When the IT 9000WM Device Emulator turns on the LED the LED icon LED2 in the I O Simulator also turns on See Figure 7 12 Vibration When the IT 9000WM Device Emulator vibrat...

Page 56: ...nsmission reception of a file with the Device Emulator is carried out ActiveSync must be used Setting ActiveSync 1 Start up ActiveSync and then navigate to File Connection Settings Figure 7 13 2 In Co...

Page 57: ...r Visual Studio 2005 and then navigate to Tools Device Emulator Manager Right click IT 9000WM Emulator in the list and then choose Cradle in the popup menu See Figure 7 15 Figure 7 15 5 Make sure Acti...

Page 58: ...n Configurations pull down menu in Visual Studio 2008 or Visual Studio 2005 and the IT 9000WM Emulator in the target device pull down menu See Figure 7 18 Figure 7 18 Debugging Applications Basic Debu...

Page 59: ...g Figure 7 20 Note If the Device Emulator does not allows break point setting in the source code step by step install Microsoft NET Compact Framework 2 0 SP2 into your PC NET Compact Framework 2 0 Ser...

Page 60: ...n Device Control Library and Common Device Control Class Library refer to Common Device Control Library Manual The example program in this chapter runs also in the Device Emulator To use the emulator...

Page 61: ...ies for 5 If the installation folder has not been registered append the following C Program Files CASIO MBSYS include 6 Choose Library files in Show directories for 7 If the files have not been regist...

Page 62: ...the Selected SDKs field Figure 8 3 4 Choose Console Application for the Application type in the Application Settings menu and click Finish button 5 In Solution Explorer click SmartDeviceApp cpp and th...

Page 63: ...ED_RED wcscpy_s msg _countof msg TEXT LED_RED break case LED_GREEN wcscpy_s msg _countof msg TEXT LED_GREEN break case LED_ORANGE wcscpy_s msg _countof msg TEXT LED_ORANGE break case LED_BLUE wcscpy_s...

Page 64: ...Figure 8 4 Figure 8 4 8 Choose Windows Mobile 6 Professional Device for the Target Device to establish connection with the PC 9 Choose Debug in Visual Studio 2008 or Visual Studio 2005 and then click...

Page 65: ...simple program using one of the system functions When running the program the LED will blink in red for 5 seconds 1 Create a new VB NET Smart Device Application in Visual Studio 2 In Solution Explore...

Page 66: ...Calib SystemLibNet Def LED_CYAN msg LED_CYAN Case Calib SystemLibNet Def LED_MAGENTA msg LED_MAGENTA Case Else msg LED_UNKNOWN End Select MessageBox Show msg LED End If Note If you type this code manu...

Page 67: ...le program using one of the system functions When running the program the LED will blink in red for 5 seconds 1 Create a new C Smart Device Application in Visual Studio NET 2 In Solution Explorer righ...

Page 68: ...temLibNet Def LED_RED msg LED_RED break case SystemLibNet Def LED_GREEN msg LED_GREEN break case SystemLibNet Def LED_ORANGE msg LED_ORANGE break case SystemLibNet Def LED_BLUE msg LED_BLUE break case...

Page 69: ...C 7 Select Deploy name of project on Build menu 8 The source code will be compiled and the application will be copied to IT 9000 By default it will be copied to Program Files name of project folder Sy...

Page 70: ...com mobility is an extremely comprehensive resource for programmers targeting WindowsCE NET based devices It includes links to most other useful web based resources You will find detailed Software and...

Reviews: