— 15 —
■
Procedure
1. Camera setting
a) Turn the power on while pressing “MENU” and “UPPER”.
After pressing “DOWN” key twice, press “DISP” and “MENU”.
Figure (a) appears.
b) Select “8 : ADJ_TEST” and then press SET.
(See Figure (b).)
c) Next, select “2. LCD” and then press SET.
(See Figure (c).)
2. Connecting the TOOL
a) Place two 9-volt alkaline batteries in C2719.
b) Connect the output terminal of C2719 to the channel terminal of the oscilloscope by the BNC-BNC cable.
c) Connect the input terminal to the Photo Diode by the BNC cable.
d) Turn the oscilloscope and C2719 on.
* Pull the ON/OFF switch of C2719 this way and raise/lower it. (See below Figure.)
d) Pressing SET causes the right figure to appear.
(See Figure (d).)
2 : L C D
1 : A D J S T A T C L R
3 : L E N S
.
.
.
1 : V C O M O K
.
.
.
O K - > R e g i s t e r W r i t e
V C O M = 0 x c a
This value is an example and differs by products.
Figure (a)
Figure (b)
Figure (c)
Figure (d)
1 : V E R S I O N
I N F O
2 : V I D E O
O U T
3 : U S B
T C C
T E S T
4 : T E S T
M E N U
5 : S O U N D
T E S T
6 : I M A G E
F L A G
7 : R O M
U P D AT E
8 : A D J
T E S T
9 : R E C - I N F O
1 0 : T E S T S C R I P T
1 1 : L A S T M E M O R Y
1 2 : F O R M AT
Summary of Contents for Exilim EX-Z57
Page 1: ...R EX Z57 MAR 2005 without price...
Page 31: ...29 PRINTED CIRCUIT BOARDS MAIN PCB TOP VIEW...
Page 32: ...30 MAIN PCB BOTTOM VIEW...
Page 33: ...31 SCHEMATIC DIAGRAMS MAIN PCB 1 2...
Page 34: ...32 MAIN PCB 2 2...