— 15 —
■
Procedure
1. Camera setting
a) Turn the power on while pressing MENU and DISP.
After pressing “Right” key twice, press MENU.
Figure (a) appears.
b) Select “8 : ADJ_TEST” and then press SET.
(See Figure (b).)
c) Next, select “1. VCOM” and then press SET.
(See Figure (c).)
2. Connecting the TOOL
a) Place two 9-volt alkaline batteries in C2719.
b) Connect the output terminal of C2719 to the channel terminal of the oscilloscope by the BNC-BNC cable.
c) Connect the input terminal to the Photo Diode by the BNC cable.
d) Turn the oscilloscope and C2719 on.
* Pull the ON/OFF switch of C2719 this way and raise/lower it. (See below Figure.)
d) Pressing SET causes the right figure to appear.
(See Figure (d).)
1 : V E R S I O N
I N F O
2 : V I D E O
O U T
3
: U S B T C C T E S T
4 : T E S T
M E N U
5 : B E E P
T E S T
6 : TA S K - 2
T E S T
7 : R O M
U P D AT E
8 : A D J
T E S T
9 : R E C - I N F O
1 0 : T E S T S C R I P T
1 1 : L A S T M E M O R Y
1 : V C O M 7 f
2 : S H U T
3 : A W B
.
.
.
V C O M A D J S TA R T ?
< < S TA R T > >
P U S H O K K E Y ?
< < S T O P > >
P U S H P W K E Y ?
O K - > R e g i s t e r W r i t e
V C O M = 0 x 7 f
This value is an example and differs by products.
Figure (a)
Figure (b)
Figure (c)
Figure (d)