background image

Operation Guide 3202

5

Troubleshooting

Time Setting

■ 

The current time setting is off by hours.

Your Home City setting may be wrong. Check your Home City setting and correct it, if 
necessary.

■ 

The current time setting is off by one hour.

You may need to change your Home City’s standard time/daylight saving time (DST) 
setting. Use the procedure under “To change the current time and date settings” to 
change the standard time/daylight saving time (DST) setting.

Sensor modes

■ 

I can’t change the temperature, barometric pressure, and altitude units.

When

TYO

 (Tokyo) is selected as the Home City, the altitude unit is set automatically 

to meters (m), the barometric pressure unit to hectopascals (hPa), and the 
temperature unit to Celsius (°C). These settings cannot be changed.

■ 

The battery indicator ( 

 ) appears while a sensor operation is being 

performed.

The battery indicator appears in the upper left corner of the digital 
display whenever there is not enough battery power available to 
perform a sensor operation in the Barometer/Thermometer Mode 
or Altimeter Mode. Sensor operation is disabled while the battery 
indicator is displayed. 

 Normal operation should return after battery power recovers.

■ 

“ERR” appears while a sensor operation is in progress.

Subjecting the watch to strong impact can cause sensor malfunction or improper 
contact of internal circuitry. When this happens, 

ERR

 (error) will appear on the display 

and sensor operations will be disabled.

Barometric

Pressure/Temperature

Measurement

Altitude

Measurement

 If 

ERR

 appears while a measurement operation is being performed in a sensor mode, 

restart the measurement. If 

ERR

 appears on the display again, it can mean there is 

something wrong with the sensor.

Barometer/Thermometer Mode and Altimeter Mode sensor operations are disabled 
whenever there is not enough battery power available to perform a sensor operation. 
This is true regardless of the current battery level. In this case, 

ERR

 will appear on 

the display. This does not indicate malfunction, and sensor operation should resume 
once battery voltage returns to its normal level.

 If 

ERR

 keeps appearing during measurement, it could mean there is a problem with 

the applicable sensor.

Whenever you have a sensor malfunction, take the watch to your original dealer or 
nearest authorized CASIO distributor as soon as possible.

■ 

The barometric pressure differential pointer does not appear on the display 

when I enter the Barometer/Thermometer Mode.

 This could indicate sensor error. Try using 

C

 to re-enter the Barometer/

Thermometer Mode.

 The barometric pressure differential pointer is not displayed when the displayed current 

barometric value is outside of the allowable measurement range (260 to 1,100 hPa).

World Time Mode

■ 

The time for my World Time City is off in the World Time Mode.

This could be due to incorrect switching between standard time and daylight saving 
time. See “To specify standard time or daylight saving time (DST) for a city” for more 
information.

Specifications

Accuracy at normal temperature:

 ±30 seconds a month

Timekeeping:

 Hour, minutes, seconds, p.m. (P), month, day, day of the week

Time format: 12-hour and 24-hour
Calendar system: Full Auto-calendar pre-programmed from the year 2000 to 2099
Other: Home City code (can be assigned one of 48 city codes); Standard Time / 

Daylight Saving Time (summer time)

Altimeter:

Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference 

altitude

Display range: –10,000 to 10,000 m (or –32,800 to 32,800 ft.)

 

Negative values can be caused by readings produced based on a reference 
altitude or due to atmospheric conditions.

Display unit: 5 m (or 20 ft.)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute 

interval for next 10 hours

Other: Reference altitude setting 

Barometer:

Measurement and display range:
 

260 to 1,100 hPa (or 7.65 to 32.45 inHg)

Display unit: 1 hPa (or 0.05 inHg)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute 

interval for next 10 hours in the Barometer/Thermometer Mode

Other: Calibration; Barometric pressure differential pointer

Thermometer:

Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Measurement timing: 5-second interval for first 3 minutes followed by 2-minute 

interval for next 10 hours

Other: Calibration

Battery indicator

Battery indicator

Pressure Sensor Precision:

Conditions

(Altitude)

Altimeter

Barometer

Fixed
temperature

0 to 6000 m
0 to 19680 ft.

± (altitude differential × 2%
+ 15 m) m
± (altitude differential × 2%
+ 50 ft.) ft.

± (pressure differential × 2%
+ 2 hPa) hPa
± (pressure differential × 2%
+ 0.059 inHg) inHg

6000 to 10000 m
19680 to 32800 ft.

± (altitude differential × 2%
+ 25 m) m
± (altitude differential × 2%
+ 90 ft.) ft.

Effect of 
variable
temperature

0 to 6000 m
0 to 19680 ft.

± 50 m every 10°C
± 170 ft. every 50°F

± 5 hPa every 10°C
± 0.148 inHg every 50°F

6000 to 10000 m
19680 to 32800 ft.

± 70 m every 10°C
± 230 ft. every 50°F

 Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).

 Precision is lessened by strong impact to either the watch or the sensor, and by 

temperature extremes.

Temperature Sensor Precision:

±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)

World Time:

 48 cities (31 time zones)

Other: Daylight Saving Time/Standard Time

Stopwatch:

Measuring unit: 1/100 second
Measuring capacity: 23:59' 59.99"
Measuring modes: Elapsed time, split time, two finishes

Countdown Timer:

Measuring unit: 1 second
Countdown start time setting range: 1 minute to 24 hours (1-hour increments and 

1-minute increments)

Alarms:

 5 Daily alarms; Hourly time signal

Illumination:

 LED (Light-emitting diode); Selectable illumination duration 

(approximately 1 second or 3 seconds)

Other:

 Low-temperature resistance (–10°C/14°F); Button operation tone on/off

Battery:

 One lithium battery (Type: CR2016)

Approximate battery operating time: 3 years under the following conditions:

 1 illumination operation (1.5 seconds) per day

 10 seconds of alarm operation per day

 10 hours of altimeter measurement, once per month

Frequent use of illumination runs down the battery.

City Code Table

City

Code

City

UTC Offset/

GMT Differential

PPG

Pago Pago

–11

HNL

Honolulu

–10

ANC

Anchorage

–9

YVR

Vancouver

–8

LAX

Los Angeles

YEA

Edmonton

–7

DEN

Denver

MEX

Mexico City

–6

CHI

Chicago

NYC

New York

–5

SCL

Santiago

–4

YHZ

Halifax

YYT

St. Johns

–3.5

RIO

Rio De Janeiro

–3

FEN

Fernando de 

Noronha

–2

RAI

Praia

–1

UTC

0

LIS

Lisbon

LON

London

MAD

Madrid

+1

PAR

Paris

ROM

Rome

BER

Berlin

STO

Stockholm

ATH

Athens

+2

CAI

Cairo

JRS

Jerusalem

City

Code

City

UTC Offset/

GMT Differential

MOW

Moscow

+3

JED

Jeddah

THR

Tehran

+3.5

DXB

Dubai

+4

KBL

Kabul

+4.5

KHI

Karachi

+5

DEL

Delhi

+5.5

KTM

Kathmandu

+5.75

DAC

Dhaka

+6

RGN

Yangon

+6.5

BKK

Bangkok

+7

SIN

Singapore

+8

HKG

Hong Kong

BJS

Beijing

TPE

Taipei

SEL

Seoul

+9

TYO

Tokyo

ADL

Adelaide

+9.5

GUM

Guam

+10

SYD

Sydney

NOU

Noumea

+11

WLG

Wellington

+12

 Based on data as of December 2009.

 The rules governing global times (GMT 

differential and UTC offset) and 
summer time are determined by each 
individual country.

Summary of Contents for 3202

Page 1: ...ometer Thermometer Mode Stopwatch Mode Countdown Timer Mode Alarm Mode Altimeter Mode Timekeeping Mode General Functions All Modes The functions and operations described in this section can be used in all of the modes Auto Return Features The watch returns to the Timekeeping Mode automatically if you do not perform any button operation for two or three minutes in the Alarm Mode The watch will retu...

Page 2: ...perature barometric pressure and altitude units Barometric Pressure Differential Pointer This pointer indicates the relative difference between the most recent barometric pressure reading and the current barometric pressure value displayed in the Barometer Thermometer Mode Reading Barometric Pressure Differential Pointer Pressure differential is indicated in the range of 5 hPa in 1 hPa units If th...

Page 3: ...l l l Altimeter Precautions This watch estimates altitude based on air pressure This means that altitude readings for the same location may vary if air pressure changes The semiconductor pressure sensor used by the watch for altitude measurements is also affected by temperature When taking altitude measurements do not subject the watch to temperature changes Do not rely upon this watch for altitud...

Page 4: ...ur Minutes Current time To set an alarm time 1 In the Alarm Mode use D to scroll through the alarm screens until the one whose time you want to set is displayed AL1 AL2 AL3 SIG AL5 AL4 2 Hold down A until the alarm time starts to flash This is the setting screen Before the alarm time starts to flash the message SET Hold will appear on the display Keep A depressed until SET Hold disappears and the ...

Page 5: ...00 ft without reference altitude Display range 10 000 to 10 000 m or 32 800 to 32 800 ft Negative values can be caused by readings produced based on a reference altitude or due to atmospheric conditions Display unit 5 m or 20 ft Measurement timing 5 second interval for first 3 minutes followed by 2 minute interval for next 10 hours Other Reference altitude setting Barometer Measurement and display...

Reviews: