Casio 3022 Operation Manual Download Page 7

Operation Guide 3022

7

Charging Guide

After a full charge, timekeeping remains enabled for up to about seven months.

The following table shows the amount of time the watch needs to be
exposed to light each day in order to generate enough power for normal
daily operations.

Since these are the specs, we can include all the technical details.

Watch not exposed to light

Internal timekeeping

Display on 18 hours per day, sleep state 6 hours per day

1 illumination operation (1.5 seconds) per day

10 seconds of alarm operation per day

10 hours of altimeter measurements, once per month

Stable operation is promoted by frequent exposure to light.

Exposure Level (Brightness)

Outdoor Sunlight (50,000 lux)

Sunlight Through a Window (10,000 lux)

Daylight Through a Window on a Cloudy Day (5,000 lux)

Indoor Fluorescent Lighting (500 lux)

Approximate

Exposure Time

5 minutes

24 minutes

48 minutes

8 hours

Recovery Times

The table below shows the amount exposure that is required to take the
battery from one level to the next.

The above exposure time values are all for reference only. Actual required
exposure times depend on lighting conditions.

Approximate Exposure Time

Level 5

Level 4

Level 3

Level 2

Level 1

2 hours

19 hours

6 hours

5 hours

96 hours

27 hours

9 hours

194 hours

54 hours

97 hours

- - - - - - - -

- - - - - - - -

Exposure Level
(Brightness)

Outdoor Sunlight
(50,000 lux)

Sunlight Through a
Window (10,000 lux)

Daylight Through a
Window on a Cloudy
Day (5,000 lux)

Indoor Fluorescent
Lighting (500 lux)

Reference

This section contains more detailed and technical information about watch
operation. It also contains important precautions and notes about the various
features and functions of this watch.

Auto Return Features

The watch returns to the Timekeeping Mode automatically if you do not
perform any button operation for two or three minutes in the Data Recall,
Alarm, or Barometer/Thermometer Mode.

If you do not perform any button operation while in the Altimeter Mode, the
watch returns to the Timekeeping Mode automatically after nine or 10 hours
(altitude measurement type : 

LONG

) or after one hour (altitude

measurement type : 

SHORT

).

If you leave a screen with flashing digits on the display for two or three
minutes without performing any operation, the watch exits the setting
screen automatically.

Scrolling

The 

B

 and 

D

 buttons are used on the setting screen to scroll through data

on the display. In most cases, holding down these buttons during a scroll
operation scrolls through the data at high speed.

Sensor Malfunction Indicator

Subjecting the watch to strong impact can cause sensor malfunction or
improper contact of internal circuitry. When this happens, 

 will appear

on the display and sensor operations will be disabled.

Barometric

 Pressure

Measurement

Altitude

Measurement

If 

 appears while a measurement operation is being performed in a

sensor mode, restart the measurement. If 

 appears on the display

again, it can mean there is something wrong with the sensor.

Even if battery power is at Level 1 or Level 2, the Barometer/Thermometer
Mode or Altimeter Mode sensor may be disabled if there is not enough
voltage available to power it sufficiently. In this case, 

 will appear on

the display. This does not indicate malfunction, and sensor operation should
resume once battery voltage returns to its normal level.

If 

 keeps appearing during measurement, it could mean there is a

problem with the applicable sensor.

Whenever you have a sensor malfunction, be sure to take the watch to
your original dealer or nearest authorized CASIO distributor as soon as
possible.

Button Operation Tone

The button operation tone sounds any time you
press one of the watch’s buttons. You can turn the
button operation tone on or off as desired.

The following tones are not affected when you
turn off the button operation tone.

Alarm
Hourly Time Signal
Countdown Timer Mode alarm
Altitude alarm
Altitude storage confirmation tone

To turn the button operation tone on and off

In any mode (except when a setting screen is on the display), hold down 

C

to toggle the button operation tone on (

 not displayed) and off (

displayed).

Since the 

C

 button also is the mode change button, holding it down to turn

the button operation on or off also causes the watch’s current mode to
change.

The 

 indicator is displayed in all modes when the button operation tone is

turned off.

Power Saving

When turned on, Power Saving enters a sleep
state automatically whenever the watch is left for
a certain period in an area where it is dark. The
table below shows how watch functions are
affected by Power Saving.

There actually are two sleep state levels:
“display sleep” and “function sleep”.

Wearing the watch inside the sleeve of clothing can cause it to enter the
sleep state.

The watch will not enter the sleep state while the digital time is between
6:00 AM and 9:59 PM. If the watch is in the sleep state already when the
digital time reaches 6:00 AM, however, it will remain in the sleep state.

The watch will not enter the sleep state while it is in the Altimeter,
Countdown Timer, or Stopwatch Mode.

Elapsed Time in

Dark

60 to 70 minutes

(Display Sleep)

6 or 7 days

(Function Sleep)

Display

Blank, with

PS 

flashing

Blank, with

PS 

not flashing

Operation

Display is off, but all functions are
enabled.

All functions are disabled, but
timekeeping is maintained.

l

l l

l l l l

l

ll

ll

ll

Power saving on
indicator

To recover from the sleep state

Perform any one of the following operations.

Move the watch to a well-lit area. It can take up to two seconds for the
display to turn on.

Press any button.

Angle the watch towards your face for reading.

To turn Power Saving on and off

1. In the Timekeeping Mode, hold down 

A

 until

the seconds start to flash, which indicates the
setting screen.

2. Press 

C

 seven times until the Power Saving

on/off screen appears.

3. Press 

D

 to toggle Power Saving on (

ON

) and

off (

OFF

).

4. Press 

to exit the setting screen.

The Power Saving on indicator (

PS

) is on the

display in all modes while Power Saving is
turned on.

Summary of Contents for 3022

Page 1: ...ad Power Supply for important information you need to know when exposing the watch to bright light If the display of the watch is blank If the display of the watch is blank it means that the watch s Power Saving function has turned off the display to conserve power See Power Saving for more information Warning The measurement functions built into this watch are not intended for taking measurements...

Page 2: ...t Each dot represents 1hPa The following shows how to interpret the data that appears on the barometric pressure graph A rising graph generally means improving weather A falling graph generally means deteriorating weather Note that if there are sudden changes in weather or temperature the graph line of past measurements may run off the top or bottom of the display The entire graph will become visi...

Page 3: ...0 000 meters 2 300 to 32 800 feet The measured altitude may be a negative value in cases where there is a reference altitude value set or because of certain atmospheric conditions The displayed altitude value changes to xxxxx meters or feet if a measured altitude falls outside the measurement range The altitude value will be displayed again as soon as the measured altitude is within the allowable ...

Page 4: ...set value during an altitude measurement operation You can press any button to stop the alarm after it starts to sound The altitude alarm sounds only while the Altimeter Mode s Altitude Graph screen or Altitude Alarm Differential screen is on the display It does not sound while the watch is in another mode or while another Altimeter Mode screen is on the display Example If you set the altitude ala...

Page 5: ... on indicator and the Hourly Time Signal on indicator are shown on the display in all modes while these functions are turned on If any alarm is on the alarm on indicator is shown on the display in all modes Illumination The display of the watch is illuminated using an EL electro luminescent panel for easy reading in the dark The watch s auto light switch turns on illumination automatically when yo...

Page 6: ...xposed to bright light whenever possible This watch uses a special rechargeable battery to store power produced by the solar cell so regular battery replacement is not required However after very long use the rechargeable battery may lose its ability to achieve a full charge If you experience problems getting the special rechargeable battery to charge fully contact your dealer or CASIO distributor...

Page 7: ...lay again it can mean there is something wrong with the sensor Even if battery power is at Level 1 or Level 2 the Barometer Thermometer Mode or Altimeter Mode sensor may be disabled if there is not enough voltage available to power it sufficiently In this case will appear on the display This does not indicate malfunction and sensor operation should resume once battery voltage returns to its normal...

Page 8: ... pressure which you can then apply to your own weather predictions However it is not intended for use as a precision instrument in official weather prediction or reporting applications Sudden temperature changes can affect pressure sensor readings Temperature measurements are affected by your body temperature while you are wearing the watch direct sunlight and moisture To achieve a more accurate t...

Reviews: