Casio 2894 Operation Manual Download Page 3

Operation Guide 2894

3

In some areas, barometric pressure is expressed in millibars (mb) instead
of hectopascals (hPa). It really makes no difference, because 1hPa = 1mb.

You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius  (

°

C)  or Fahrenheit

(

°

F) as the display unit for the measured temperature value. See “To select

the temperature, barometric pressure, and altitude units”.

See “Barometer and Thermometer Precautions” for important precautions.

Barometric Pressure Graph

Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure measurements automatically every two
hours (at the top of each even-numbered hour), regardless of its current
mode. Measurement results are used to produce barometric pressure graph
and barometric pressure differential pointer readings.
The barometric pressure graph shows readings of previous measurements for
up to 30 hours. The horizontal axis of the graph represents time, with each dot
standing for two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each dot
standing for the relative difference between its reading and that of the dots
next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.

A rising graph generally means improving weather.

A falling graph generally means deteriorating weather.

Note that if there are sudden changes in weather or
temperature, the graph line of past measurements may run
off the top or bottom of the display. The entire graph will
become visible once barometric conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.

Barometric reading that is out of range (260 hPa/mb to 1,100 hPa/mb or
7.65 inHg to 32.45 inHg)

Sensor malfunction

Not visible on
the display.

Barometric Pressure Differential Pointer

This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode

Pressure differential is indicated in the range of 

±

15 hPa, in 1-hPa units.

The barometric pressure differential pointer is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (260 to 1,100 hPa).

Barometric pressure is calculated and displayed using hPa as the standard.
The  barometric pressure differential can also be read in inHg units as
shown in the illustration.

Pressure differential
examples in the
illustration are indicated
in 10 hPa/0.3 inHg
steps.

Current pressure
less than most
recent measured
pressure

Points to 9 o'clock for
differentials outside
the range of 

±

15 hPa/

±

0.44 inHg.

Current pressure
greater than most
recent measured
pressure

Barometric pressure
differential pointer

inHg values

hPa values

To turn display of the barometric pressure differential pointer on
and off

1. In the Barometer/Thermometer Mode, hold

down 

E

 until 

SET

 appears in the upper

display area.

2. Release 

E

, and wait for four or five more

seconds until either 

OFF

 or the current

reference temperature value (if set) start to
flash. This is the setting screen.

3. Press 

D

 twice to display the pointer on/off

setting screen.

l l l

l

l

ll

ll

ll

ll

l

l

l l

l l l

About Barometric and Temperature Measurements

Barometric pressure and temperature measurement operations are
performed as soon as you enter the Barometer/Thermometer Mode. After
that, barometric pressure and temperature measurements are taken every
five seconds.

The 

ACT

 indicator flashes on the display while a measurement is in

progress.

You can also perform a barometric pressure and temperature measurement
at any time by pressing 

B

 in the Barometer/Thermometer Mode.

Altimeter

The watch's altimeter uses a pressure sensor to detect current air pressure,
which is then used to estimate the current altitude based on ISA (International
Standard Atmosphere) preset values. You can also specify a reference
altitude, which the watch will use to calculate your current altitude based on
the value you specify. Altimeter functions also include storage of
measurement data in memory and an altitude alarm.

Important!

This watch estimates altitude based on air pressure. This means that
altitude readings for the same location may vary if air pressure changes.

The semiconductor pressure sensor used by the watch for altitude
measurements is also affected by temperature. When taking altitude
measurements, make sure the watch is not subjected to temperature
changes.

To avoid the effect of sudden temperature changes during measurement,
keep the watch on your wrist in direct contact with your skin.

Do not rely upon this watch for altitude measurements or perform button
operations while sky diving, hang gliding, or paragliding, while riding a
gyrocopter, glider, or any other aircraft, or while engaging in any other
activity where there is the chance of sudden altitude changes.

Do not use this watch for measuring altitude in applications that demand
professional or industrial level precision.

Remember that the air inside of a commercial aircraft is pressurized.
Because of this, the readings produced by this watch will not match the
altitude readings announced or indicated the flight crew.

How the Altimeter Measures Altitude

The altimeter can measure altitude based on its own preset values, or a
reference altitude specified by you.

When you measure altitude based on preset values

Data produced by the watch's barometric pressure sensor is converted to
approximate altitude based on ISA (International Standard Atmosphere)
conversion values stored in watch memory.

When you measure altitude using a reference altitude specified by you

After you specify a reference altitude, the watch uses that value to convert the
current measured barometric pressure value to altitude.

To determine the height of a tall building, for
example, specify zero for the reference
altitude value while you are on the ground
floor. Then when you go to a higher floor, the
altitude displayed by the watch will indicate
the height from the ground floor. Note that
you may not be able to get a good reading if
the building is pressurized or air-conditioned.

When mountain climbing, you can set the
reference value in accordance with a marker
along the way or altitude information from a
map. After that, the altitude readings
produced by the watch will be more accurate
than they would without a reference altitude.

400

B

A

4. Press 

C

 to toggle display of the barometric pressure differential pointer

on (

ON

 displayed) and off (

OFF

 displayed).

5. When the setting is the way you want, press 

E

 to exit the setting screen.

Displaying Your Current Altitude

You can use the procedure described in this section to display your current
altitude. If you leave the watch in the Altimeter Mode, it will regularly update
the displayed altitude value, and indicate reading-to-reading changes in the
altitude graph at the top of the display.

Important!

The procedure in this section simply displays values indicating your current
altitude, without storing them in watch memory. For information about
recording altitude readings in watch memory, see “Saving Altitude Data”.

Summary of Contents for 2894

Page 1: ...ision Values produced by this watch should be considered as reasonable representations only When engaging in mountain climbing or other activities in which losing your way can create a dangerous or life threatening situation always be sure to use a second compass to confirm direction readings CASIO COMPUTER CO LTD assumes no responsibility for any loss or any claims by third parties that may arise...

Page 2: ... Digital Compass measurement operation After about two seconds the direction that the 12 o clock position of the watch is pointing appears on the display Also four pointers appear to indicate magnetic north south east and west After the first reading is obtained the watch continues to take direction readings automatically each second for up to 20 seconds Direction indicator Angle value in degrees ...

Page 3: ...e measurement operations are performed as soon as you enter the Barometer Thermometer Mode After that barometric pressure and temperature measurements are taken every five seconds The ACT indicator flashes on the display while a measurement is in progress You can also perform a barometric pressure and temperature measurement at any time by pressing B in the Barometer Thermometer Mode Altimeter The...

Page 4: ...le a sa ve session is in progress Data High Altitude Low Altitude Total Ascent Total Descent Relative Altitude Change Description Highest altitude reached during the current session Lowest altitude reached during the current session Total cumulative ascent during the current session Total cumulative descent during the current session Relative change in altitude during the current session The maxim...

Page 5: ...ound The altitude alarm sounds only while the Altimeter Mode s Altitude Screen is on the display It does not sound while the watch is in another mode or while another Altimeter Mode screen is on the display Example If you set the altitude alarm at 130 meters it sounds when you pass the 130 meter mark on your way up and on your way back down To set the altitude alarm 1 In the Altimeter Mode hold do...

Page 6: ...ude screen without deleting the data World Time World Time digitally displays the current time in 30 cities 29 time zones around the world For full information on city codes see the City Code Table All of the operations in this section are performed in the World Time Mode which you enter by pressing D Timekeeping Mode time Current time in the zone of the selected city code To view the time in anot...

Page 7: ...rm time using the 12 hour format take care to set the time correctly as a m no indicator or p m P indicator 5 Press E to exit the setting screen AL1 SIG AL2 AL3 AL4 AL5 C A Alarm Operation The alarm sounds in all modes at the preset time for about 10 seconds or until you stop it by pressing any button To test the alarm In the Alarm Mode hold down C to sound the alarm To turn an alarm and the Hourl...

Page 8: ...g atmospheric pressure indicates good weather while falling pressure indicates deteriorating weather conditions The barometric pressures that you see in the newspaper and on the TV weather report are measurements corrected to values measured at 0 m sea level Question How does the altimeter work Answer Generally air pressure and temperature decrease as altitude increases This watch bases its altitu...

Page 9: ...te that allowing the watch to become very hot can cause its liquid crystal display to black out The appearance of the LCD should become normal again when the watch returns to a lower temperature Warning Leaving the watch in bright light to charge its rechargeable battery can cause it to become quite hot Take care when handling the watch to avoid burn injury The watch can become particularly hot wh...

Page 10: ...he watch under your sleeve while the auto light switch is turned on can cause frequent illumination of the display and can run down the battery Illumination may not turn on if the face of the watch is more than 15 degrees above or below parallel Make sure that the back of your hand is parallel to the ground Illumination turns off after the preset illumination duration see To specify the illuminati...

Page 11: ...y to your own weather predictions It is not intended for use as a precision instrument in official weather prediction or reporting applications Sudden temperature changes can affect pressure sensor readings Temperature measurements are affected by your body temperature while you are wearing the watch direct sunlight and moisture To achieve a more accurate temperature measurement remove the watch f...

Page 12: ...lanca Dakar Abidjan Milan Rome Madrid Amsterdam Algiers Hamburg Frankfurt Vienna Stockholm 11 HNL ANC LAX DEN CHI NYC CCS RIO 02 01 GMT LON PAR BER Athens Cairo Jerusalem Jeddah Tehran Dubai Kabul Karachi Delhi Dhaka Yangon Bangkok Hong Kong Seoul Tokyo Adelaide Sydney Noumea Wellington 02 0 03 0 03 5 04 0 04 5 05 0 05 5 06 0 06 5 07 0 08 0 09 0 09 5 10 0 11 0 12 0 Helsinki Istanbul Beirut Damascu...

Reviews: