Casio 2872 Operation Manual Download Page 6

Operation Guide 2872

6

To turn the auto light switch on and off

In any mode except while a setting is flashing on the display, hold down 

L

 for

about two seconds to toggle the auto light switch on (

 displayed) and off

(

 not displayed).

The auto light switch on indicator (

) is on the display in all modes while

the auto light switch is turned on.

The auto light switch turns off automatically whenever battery power drops
to Level 3.

The backlight may not light right away if you raise the watch to your face
while a barometric pressure or altitude measurement operation is in
progress.

The auto light switch is always disabled, regardless of its on/off setting,
when any one of the following conditions exists.

While an alarm is sounding
While a direction measurement operation is being performed or while a
bearing sensor calibration operation in the Digital Compass Mode

To specify the illumination duration

1. In the Timekeeping Mode, hold down 

A

 until

the seconds start to flash, which indicates the
setting screen.

2. Press 

B

 to toggle the illumination duration

setting between 2.5 seconds (

) and 1.5

seconds (

).

3. After the setting is the way you want, press 

A

to exit the setting screen.

ll

lll

ll

l l

l l l ll

ll

ll

Questions & Answers

Question: What causes incorrect direction readings?
Answer:

Incorrect bidirectional calibration. Perform bidirectional calibration.

Nearby source of strong magnetism, such as a household appliance, a
large steel bridge, a steel beam, overhead wires, etc., or an attempt to
perform direction measurement on a train, boat, etc. Move away from large
metal objects and try again. Note that digital compass operation cannot be
performed inside a train, boat, etc.

Question: What causes different direction readings to produce different

results at the same location ?

Answer: Magnetism generated by nearby high-tension wires is interfering with

detection of terrestrial magnetism. Move away from the high-tension
wires and try again.

Question: Why am I having problems taking direction readings indoors ?
Answer: A TV, personal computer, speakers, or some other object is

interfering with terrestrial magnetism readings. Move away from the
object causing the interference or take the direction reading
outdoors. Indoor direction readings are particularly difficult inside
ferro-concrete structures. Remember that you will not be able to take
direction readings inside of trains, airplanes, etc.

Question: How does the barometer work?
Answer: Barometric pressure indicates changes in the atmosphere, and by

monitoring these changes you can predict the weather with
reasonable accuracy. Rising atmospheric pressure indicates good
weather, while falling pressure indicates deteriorating weather
conditions.
The barometric pressures that you see in the newspaper and on the
TV weather report are measurements corrected to values measured
at 0 m sea level.

Question: How does the altimeter work?
Answer: Generally, air pressure and temperature decrease as altitude

increases. This watch bases its altitude measurements on
International Standard Atmosphere (ISA) values stipulated by the
International Civil Aviation Organization (ICAO). These values define
relationships between altitude, air pressure, and temperature.

0 m

500 m

1000 m

1500 m

2000 m

2500 m

3000 m

3500 m

4000 m

899 hPa

795 hPa

701 hPa

616 hPa

8.5

°

C

2

°

C

–4.5

°

C

–11

°

C

15

°

C

1013 hPa

About 6.5

°

per 1000 m

About 8 hPa per 100 m

About 9 hPa per 100 m

About 10 hPa per 100 m

About 11 hPa per 100 m

About 12 hPa per 100 m

Altitude

Air Pressure

Temperature

Note that the following conditions will prevent you from obtaining accurate
readings:
When air pressure changes because of changes in the weather
Extreme temperature changes
When the watch itself is subjected to strong impact

0 ft

2000 ft

4000 ft

6000 ft

8000 ft

10000 ft

12000 ft

14000 ft

25.84 inHg

22.23 inHg

19.03 inHg

44.7

°

F

30.5

°

F

16.2

°

F

59.0

°

F

29.92 inHg

About 3.6

°

per 1000 ft

About 0.15 inHg per 200 ft

About 0.17 inHg per 200 ft

About 0.192 inHg per 200 ft

About 0.21 inHg per 200 ft

Source:   International Civil Aviation Organization

Height of building 130 m
(relative altitude)

Rooftop at an altitude of
230 m above sea level
(absolute altitude)

Sea

There are two standard methods of expressing altitude: Absolute altitude and
relative altitude. Absolute altitude expresses an absolute height above sea
level. Relative altitude expresses the difference between the height of two
different places.

Precautions Concerning Simultaneous Measurement of Altitude and
Temperature
Though you can perform altitude and temperature measurements at the same
time, you should remember that each of these measurements requires
different conditions for best results. With temperature measurement, it is best
to remove the watch from your wrist in order to eliminate the effects of body
heat. In the case of altitude measurement, on the other hand, it is better to
leave the watch on your wrist, because doing so keeps the watch at a
constant temperature, which contributes to more accurate altitude
measurements.
The following describes what you should do to give priority to either altitude or
temperature.

To give altitude measurement priority, leave the watch on your wrist or in
any other location where the temperature of the watch is kept constant.

To give temperature measurement priority, remove the watch from your
wrist and allow it to hang freely from your bag or in another location where
it is not exposed to direct sunlight. Note that removing the watch from your
wrist can momentarily affect pressure sensor readings.

Power Supply

This watch is equipped with a solar cell and a special rechargeable battery
(secondary battery) that is charged by the electrical power produced by the
solar cell. The illustration shown below shows how you should position the
watch for charging.

Example: Orient the watch so its face is

pointing at a light source.

The illustration shows how to position a
watch with a resin band.

Note that charging efficiency drops when
any part of the solar cell is blocked by
clothing, etc.

Normally, you should try to keep the
watch outside of your sleeve as much as
possible. Charging is significantly reduced
if the face is only partially covered.

Solar cell

Important!

Storing the watch for long periods in an area where there is no light or
wearing it in such a way that it is blocked from exposure to light can cause
rechargeable battery power to run down. Be sure that the watch is normally
exposed to bright light whenever possible.

This watch uses a special rechargeable battery to store power produced by
the solar cell, so regular battery replacement is not required. However, after
very long use, the rechargeable battery may lose its ability to achieve a full
charge. If you experience problems getting the special rechargeable battery
to fully charge, contact your dealer or CASIO distributor about having it
replaced.

Never try to remove or replace the watch’s special battery yourself. Use of
the wrong type of battery can damage the watch.

All data stored in memory is deleted, and the current time and all other
settings return to their initial factory defaults whenever battery power drops
to Level 4 and when you have the battery replaced.

Turn on the watch’s Power Saving function and keep it in an area normally
exposed to bright light when storing it for long periods. This helps to keep
the rechargeable battery from going dead.

Summary of Contents for 2872

Page 1: ...ference section Sensor Light General Guide The illustration below shows which buttons you need to press to navigate between modes In any mode press L to illuminate the display You can use buttons B D and E to directly enter a sensor mode from the Timekeeping Mode or from another sensor mode To enter a sensor mode from the Stopwatch Countdown Timer Data Recall or Alarm Mode first enter the Timekeep...

Page 2: ...t that readings are incorrect To take barometric pressure and temperature readings Pressing E in the the Timekeeping or in any of other sensor modes enters the Barometer Thermometer Mode and automatically starts taking barometric pressure and temperature measurements It can take up to four or five seconds for the barometric pressure reading to appear after you enter the Barometer Thermometer Mode ...

Page 3: ...r Note however that you may not be able to get a good reading if the building is pressurized or air conditioned When mountain climbing you can set the reference value in accordance with a marker along the way or altitude information from a map After you do this the altitude readings produced by the watch will be more accurate than they would be without a reference altitude 400 B A To take an altit...

Page 4: ...ment All of the operations in this section are performed in the Stopwatch Mode which you enter by pressing C Minutes Seconds 1 100 second Timekeeping Mode time Seconds indicator Hours Minute indicator To measure times with the stopwatch J J J J J J J J J J J First runner finishes Display time of first runner Second runner finishes J Elapsed Time E E E E A Start Stop Re start Stop Clear Split Time ...

Page 5: ...e 1 In the Alarm Mode use D to scroll through the alarm screens until the one whose time you want to set is displayed 2 Hold down A until the hour setting of the alarm time start to flash which indicates the setting screen This automatically turns on the alarm 3 Press C to move the flashing between the hour and minute settings 4 While a setting is flashing use D and B to change it When setting the...

Page 6: ... When air pressure changes because of changes in the weather Extreme temperature changes When the watch itself is subjected to strong impact 0 ft 2000 ft 4000 ft 6000 ft 8000 ft 10000 ft 12000 ft 14000 ft 25 84 inHg 22 23 inHg 19 03 inHg 44 7 F 30 5 F 16 2 F 59 0 F 29 92 inHg About 3 6 F per 1000 ft About 0 15 inHg per 200 ft About 0 17 inHg per 200 ft About 0 192 inHg per 200 ft About 0 21 inHg p...

Page 7: ...ekeeping remains enabled for up to about six months The following table shows the amount of time the watch needs to be exposed to light each day in order to generate enough power for normal daily operations Approximate Exposure Time 5 minutes 24 minutes 48 minutes 8 hours Exposure Level Brightness Outdoor Sunlight 50 000 lux Sunlight Through a Window 10 000 lux Daylight Through a Window on a Cloud...

Page 8: ...Canada while the magnetic south pole is in southern Australia Note that the difference between magnetic north and true north as measured with all magnetic compasses tends to be greater as one gets closer to either of the magnetic poles You should also remember that some maps indicate true north instead of magnetic north and so you should make allowances when using such maps with this watch Locatio...

Page 9: ... the sensor to correct the errors Important Incorrectly calibrating the temperature sensor can result in incorrect readings Carefully read the following before doing anything Compare the readings produced by the watch with those of another reliable and accurate thermometer If adjustment is required remove the watch from your wrist and wait for 20 or 30 minutes to give the temperature of the watch ...

Reviews: