Casio 2782 Operation Manual Download Page 8

Operation Guide 2782

8

3. After waiting four or five seconds, 

C

 to move

the flashing to the pressure sensor calibration
setting.

At this time, 

OFF

 or the barometric

pressure value should be flashing on the
display.

If 

OFF

 or the pressure value does not

appear at this time, press 

A

 to return to the

Barometer/Thermometer Mode screen, and
perform step 2 again.

4. Press 

D

 (+) or 

B

 (–) to change the displayed barometric pressure by 1

hPa (0.05 inHg).

Pressing 

D

 and 

B

 at the same time returns to the factory calibration

(

OFF

).

5. Press 

A

 to return to the Barometer/Thermometer Mode screen.

ll

ll

l l

l l l l l l l l

ll

ll

ll

To change the altitude unit

1. Press 

D

 to enter the Altimeter Mode.

2. Hold down 

A

 until 

OFF

 appears (flashing) or

until the display goes blank. This is the setting
screen.

Wait for four or five seconds before
performing step 3, below. If you don’t wait,
there is the chance of setting value error.

If the display went blank in step 2, the
current reference value will appear
(flashing) on the display after the four or five
seconds pass.

If 

OFF

 or the current reference altitude value does not appear at this

time, press 

A

 to return to the Altimeter Mode screen, and perform step

2 again.

3. Press 

C

 to move the flashing to the altitude unit setting.

ll

l l

l l l

ll

4. Press 

D

 to select the unit you want (

m

 or 

ft

).

5. Press 

A

 to return to the Altimeter Mode screen.

The altitude unit you select in the Altimeter Mode is also used in the Depth
Gauge Mode.

To manually reset the reference depth to 0 meters (feet)

In the Depth Gauge Mode, press 

C

 and 

D

 at

the same time.

This resets the reference depth and causes the
displayed depth to change to 0 meters (feet).

Never perform the above operation while
submerged.

Summary of Contents for 2782

Page 1: ...ween modes In any mode press L to illuminate the display Countdown Timer Mode Stopwatch Mode C Altimeter Mode C Press C Press D Alarm Mode Hand Setting Mode C Press C C C Timekeeping This watch features separate digital and analog timekeeping The procedures for setting the digital time and analog time are different Whenever you need to adjust both the digital and the analog time settings make sure...

Page 2: ...ric pressure history graph A rising graph generally means improving weather A falling graph generally means deteriorating weather About Barometric and Temperature Measurements Barometric pressure and temperature measurement operations are performed as soon as you enter the Barometer Thermometer Mode After that barometric pressure and temperature measurements are taken every five seconds for the fi...

Page 3: ...esigned to start depth measurement and record data in memory after a depth of 1 meter 4 feet is reached Because of this the explanations in this User s Guide uses the term submerged to refer to any depth deeper than 1 meter and the on the surface to refer to any depth shallower than 1 meter Leaving the watch in the Depth Gauge Mode while not in the water consumes battery power Exit the Depth Gauge...

Page 4: ... stored in memory To view log data 1 While in the Timekeeping Mode press C to enter the Depth Gauge Mode 2 Press B to cycle through the data screens in the sequence shown below If you do not perform any button operation for about five or six seconds while a Log Data screen is on the display the watch will automatically return to the Depth Gauge Mode screen Maximum depth Water temperature at maximu...

Page 5: ...ntil you stop it by pressing any button To test the alarm In the Alarm Mode hold down D to sound the alarm To turn an alarm and the Hourly Time Signal on and off 1 In the Alarm Mode use D to select an alarm or the Hourly Time Signal 2 When the alarm or the Hourly Time Signal you want to is selected press B to turn it on and off Indicates alarm is ON Indicates Hourly Time Signal is ON The alarm on ...

Page 6: ... mind when diving at high altitudes or in fresh water Answer The depth reading is automatically reset to 0 0 m 0 ft whenever the Depth Gauge Mode is entered so you can use this watch for skin diving at altitudes Note however that malfunctions occur when skin diving at altitudes greater than approximately 4 000 meters 13 000 ft In addition as this watch bases its calculations on sea water which has...

Page 7: ...OFF or a barometric pressure value if set If a barometric value is set the display goes blank for four or five seconds and then the currently set pressure value appears l l l l l l l l l l l l l l If OFF or a value does not appear in the upper and lower parts of the display press A again to exit the setting screen and repeat step 2 of this procedure 3 After waiting four or five seconds press C to ...

Page 8: ... This is the setting screen Wait for four or five seconds before performing step 3 below If you don t wait there is the chance of setting value error If the display went blank in step 2 the current reference value will appear flashing on the display after the four or five seconds pass If OFF or the current reference altitude value does not appear at this time press A to return to the Altimeter Mod...

Reviews: