background image

1675-6

Deleting Data

Delete data in the Recall Mode. The actual procedure you should use to
delete data depends on the type of data it is.

To delete auto memory data

The following procedure deletes an entire set (from start measurement to end
measurement) of auto memory data.

Important!

You cannot delete data while an auto memory
measurement is in progress (“AUTO” flashing
on the display).

1. In the Recall Mode, display the start data

of the set of auto memory data that you
want to delete.

2. To clear the data, hold down 

A

 until the

watch emits a beep (and until “CLR” stops
flashing on the display).

To delete manual memory, maximum, and minimum data

1. In the Recall Mode, display the data that you want to delete.
2. To clear the data, hold down 

A

 until the watch emits a beep (and until

“CLR” stops flashing on the display).

ERROR WARNING FUNCTION

This watch is designed to automatically stop taking measurements when
there is a sensor malfunction, when battery power drops below a certain
level, or when battery voltage is decreased below a certain level due to very
cold temperatures.

Sensor malfunction

Low battery

Important!

If the sensor is malfunctioning when it comes time for an barometric
pressure measurement to be taken, the barometric pressure value appears
as “– – – –” on the display and the corresponding point on the barometric
pressure graph is left blank.

There may be cases where the “ERROR” or “BATTERY” message is
cleared once you change modes. In this case, you can continue using the
watch normally unless the error warning message reappears.

Whenever there is a sensor malfunction, be sure to take the watch to an
authorized CASIO distributor or Service Center as soon as possible. If the
appearance of the “BATTERY” message is caused by extremely low
temperature, the message should clear from the display when normal
temperature returns. It is recommended, however, that you still have the
watch checked by an authorized CASIO distributor or Service Center.

C

D

B

A

A

°

C

m

RECALL

AUTO

( Auto Memory Start Display )

Auto memory
measurement indicator

ERROR

P

°

C

m

ALTI

AUTO

ERROR

P

°

C

hPa mb 

ERROR

During Barometric Pressure

Measurement

During Altitude Measurement

BATTERY 

P

°

C

m

ALTI

AUTO

BATTERY 

P

°

C

hPa mb 

BATTERY

During Barometric Pressure

Measurement

During Altitude Measurement

ALARM FUNCTIONS

When the Daily Alarm is on, the alarm sounds
for 20 seconds at the preset time each day.
Press any button to stop the alarm after it
starts to sound.
When the Hourly Time Signal is on, the watch
beeps every hour on the hour.

To set the alarm time

1. Use 

C

 to enter the Alarm Mode.

2. Hold down 

A

 until the hour digits flash on the display. The hour digits

flash because they are 

selected.

• At this time, the alarm is automatically switched on.

3. Press 

C

 to change the selection in the following sequence.

4. Press 

D

 to increase the selected digits. Holding down 

D

 changes the

selection at high speed.

• The format (12-hour and 24-hour) of the alarm time matches the format you

select for normal timekeeping.

• When setting the alarm time using the 12-hour format, take care to set the

time correctly as morning (A) or afternoon (P).

5. After you set the alarm, press 

A

 to return to the Alarm Mode.

To switch the Daily Alarm and Hourly Time Signal on and off

Press 

D

 while in the Alarm Mode to change the status of the Daily Alarm and

Hourly Time Signal in the following sequence.

  [Alarm ON Indicator / Hourly Time Signal ON Indicator]

To test the alarm

Hold down 

D

 while in the Alarm Mode to sound the alarm.

STOPWATCH FUNCTIONS

The Stopwatch Functions let you record
elapsed time, split times, and two finishes.
The range of the stopwatch is 23 hours, 59
minutes, 59.99 seconds.
Stopwatch functions are available in the Stop-
watch Mode, which you can enter using 

C

.

C

D

B

A

A

Both ON

Both OFF

Hourly Time
Signal only

Daily Alarm only

Mode indicator

Minutes

Hour

Alarm on
indicator

Hourly time signal
on indicator

Hour

Minutes

C

D

B

A

Minutes

Hours

1/100 second

Seconds

(a) Elapsed time measurement

(b) Split time measurement

(c) Split time and 1st-2nd place times

D

D

D

D

B

Stop

Re-start

Clear

Start

Stop

D

B

B

D

B

Start

Split

Split release

Stop

Clear

B

D

D

B

B

Start

Split release

Stop

Split

Clear

First runner
finishes.

Second runner finishes.
Record time of first runner.

Record time of
second runner.

Mode indicator

Summary of Contents for 1675

Page 1: ...less of the auto backlight function on off setting About the Auto Backlight function While the Auto Backlight function is turned on the backlight automatically lights for about two seconds in any mode whenever you position your wrist as described below Auto backlight indicator OFF ON Important Avoid wearing the watch on the inside of your wrist Doing so causes the Auto Backlight to operate when it...

Page 2: ...D B A P Day of week Month Minutes Hour Seconds Date Year PM indicator C D B A P C hPa mb Barometric pressure graph 1 Unit 1 hPa mb 0 05 inHg Temperature Last measurement updated every 2 hours 2 Barometric Pressure Temperature Display BAROMETER FUNCTIONS This watch uses a pressure sensor to measure air pressure This sensor can be calibrated Important The barometer that is built into this watch meas...

Page 3: ...30 minutes to give the temperature of the watch time to stabilize Temperature Barometric Pressure Temperature Display C D B A C hPa mb To calibrate the temperature 1 In the Timekeeping Mode use D to display the barometric pressure and temperature 2 Hold down A until the display clears OFF or the temperature value should be flashing on the display The OFF indicator appears when the factory setting ...

Page 4: ...After 4 or 5 seconds either OFF or the current reference altitude value if set will start to flash The data flashes because it is selected 2 Press C to change the selection in the following sequence 3 Press C to select the Memory Measurement Setting display with either AUTO or MANUAL flashing 4 Press D to switch between auto memory measurement AUTO flashing or manual memory measurement MANUAL flas...

Page 5: ...h auto memory measurements AUTO shown on the display the start point is the first altitude measured With manual memory measurements MANUAL shown on the display the start point is 0 m 0 ft The target altitude graph is not shown on the display if the altitude alarm is off Example The display below would appear at a current altitude of 160 m when you are using manual memory measurement with a target ...

Page 6: ...tor ERROR P C m ALTI AUTO ERROR P C hPa mb ERROR During Barometric Pressure Measurement During Altitude Measurement BATTERY P C m ALTI AUTO BATTERY P C hPa mb BATTERY During Barometric Pressure Measurement During Altitude Measurement ALARM FUNCTIONS When the Daily Alarm is on the alarm sounds for 20 seconds at the preset time each day Press any button to stop the alarm after it starts to sound Whe...

Page 7: ... report are measurements corrected to values measured at 0 m sea level 540 hPa mb 616 hPa mb 701 hPa mb 795 hPa mb 899 hPa mb 1013 hPa mb 472 hPa mb 0 m 500 m 1000 m 1500 m 2000 m 2500 m 3000 m 3500 m 4000 m 4500 m 5000 m 5500 m 6000 m 8 5 C 2 C 4 5 C 11 C 17 5 C 24 C 15 C About 6 5 C per 1000 m About 6 7 hPa mb per 100 m About 7 hPa mb per 100 m About 8 hPa mb per 100 m About 9 hPa mb per 100 m A...