When d6 is 1~9,be sure d7,d8,d9,d10 are 0,and d11 is 5~9
Initial character, terminator automatically inserted
When print EAN13(m = 2 or 67),Please pay attention as following:
Whatever the input data length is 12 or 13,check bit is automatically
inserted or corrected
Initial character, central split character and terminator inserted
automatically
When print EAN8(m = 3 or 68),please pay attention as following:
Whatever input data length is 7 or 8,the check bit is automatically inserted
or corrected
Initial character, central split character and terminator inserted
automatically
When print CODE39(m = 4 or 69),please pay attention as following:
When d1 or dn are not Initial character/terminator ”*”, encoder is
automatically inserted ”*”
When middle of the data encounter ”*”, the encoder regard it as
terminator, the other data as the normal data;
The check bit could not calculate and add automatically
When print ITF25(m = 5 or 70), please pay attention as following:
Initial character and terminator inserted automatically
The check bit could not calculate and add automatically
When print CODABAR (NW-7) (m = 6 or 71),please pay attention as
following:
Initial character and terminator could not inserted automatically, but
manual addition by user, that the range from “A”~”D” or “a”~”d”
Check bit could not calculate and add automatically
When print CODE93(m = 72),please pay attention as following:
Initial character and terminator inserted automatically
The two check code are automatically calculated and then inserted
When barcode readable character(HRI) is set to print, there is no HRI
character which indicating start/end
When barcode readable character(HRI) is set to print, the control