CashConcepts CCE 410 User Manual Download Page 4

 

 

CashConcepts 

CCE 410 

 

 

 
Operating procedure 

 

Normal Counting 

Press COUNT/BATCH key to select normal counting mode. The indicator lights on the key lit and indicates the 
activation of this function.  
 

Sorted Coins 

Select diameter & thickness knob position according to the coins which should be counted. Place coins into the 
coin field and press START/STOP key to start the counting. Coins are transported to the coin hopper and process 
at high speed and discharged to the coin bag or coin receptacle. The machine stops after 5 seconds when no more 
coin pass the sensor. Press START/STOP to stop the machine at any time. 
 

Mixed Denominations 

Select diameter & thickness knob position according to the largest coin denomination. Place coins into the coin 
field and press START/STOP key to start the counting. Coins are transported to the coin hopper and process at 
high speed. Largest coins are counted and discharged to the coin bag or coin receptacle and all others to the reject 
pocket.  
 
Repeat the process until all denomination coins are counted.  
 

ADD function 

To accumulate counting results, press ADD/STORE key once. The indicator lamp on the key lit and ensures the 
activation of this function. Machine will automatically accumulate every coins are being counted. Release 
ADD/STORE key to deactivate this function. 
 

STORE function 

This machine allows user to view the last counting result. To view the last counting result on the display follow the 
next steps: 
 

1.

 

Press ADD/STORE key. The indicator light on the key lit ensuring the activation. 

2.

 

Press RD key. Last counting result will be displayed.  

 

Batch Settings 

User can count a bag of coins having a pre-set batch number from 1 to 9999 using 4 numeric keys on the control 
panel. Pre-Set batch number is displayed on the batch display. 
 
Press COUNT/BATCH key on the control panel until the lamp n the key is off and batch display shows “P”. 
 
Use 4 numeric keys (+1000, +100, +10, +1) to select any batch number.  
 
After selection of batch value, press START/STOP  to start counting and the machine stops automatically when the 
counting number reached the batch number. Resume counting next batch by pressing START/STOP key.  During 
batch counting, you can also accumulate batch-counting results by pressing ADD/STORE key.  
 

Summary of Contents for CCE 410

Page 1: ...pts Europe GmbH Kemptener Stra e 99 D 88131 Lindau Tel 49 0 8382 94315 0 Fax 49 0 8382 94315 20 Email sales cashconcepts cc Web www cashconcepts cc M nzz hl und Sortiermaschine Coin counter and sorter...

Page 2: ...cts e g paper clips fall in the machine these can block the engines and the sensitive sensors of the machine and damage or destroy them Please note that during the countable process no ties hair or cl...

Page 3: ...mm 1 36 mm 1 36 mm 1 51 mm 1 63 mm 1 88 mm 2 13 mm 1 95 mm How to use the 410 The CCE 410 can be easily used by the following buttons START STOP Starts or stops the counting COUNT BATCH Here you can s...

Page 4: ...coins are counted ADD function To accumulate counting results press ADD STORE key once The indicator lamp on the key lit and ensures the activation of this function Machine will automatically accumula...

Page 5: ...ay Error Code Meaning Action Eb0 Coin jamming error Coins are jammed near the counting sensor 1 Open side cover and remove jammed coins 2 Close side cover and press CLEAR key to clear error message 3...

Page 6: ...age Replace power fuse Contact CCE Service Coin jamming Improper adjustment of diameter and thickness know Adjust diameter and thickness knob according to coin denomination Coins rotate inside the hop...

Page 7: ...0 which you can solve with the help of this manual then you please get in contact to us by email and describe the problem we will get in contact to you as soon as possible with a proposal for solution...