CashCode SNR Software Description Download Page 2

  

EXTERNAL COMMUNICATION INTERFACE FEATURES: 

 

MDB INTERFACE 

 

Country Code = 1937h 

 

Decimal Place = 0 

 

Scaling Factor =

 

50 

 

MDB Level: 1(sw2.3=OFF) or 2 (sw2.3=ON) 
 

 

DIP SWITCHES SETTING: 

 

Switch 1 

ON state 

OFF state 

Default 
Setting 

SW1.1 

50 VEF Disabled 

50 VEF Enabled 

OFF 

SW1.2 

100 VEF Disabled 

100 VEF Enabled 

OFF 

SW1.3 

500 VEF Disabled 

500 VEF Enabled 

OFF 

SW1.4 

1000 VEF Disabled 

1000 VEF Enabled 

OFF 

SW1.5 

2000 VEF Disabled 

2000 VEF Enabled 

OFF 

SW1.6 

5000 VEF Disabled 

5000 VEF Enabled 

OFF 

SW1.7 

Reserved 

Reserved 

OFF 

SW1.8 

Reserved 

Reserved 

OFF 

 

Switch 2 

ON state 

OFF state 

Default 
Setting 

SW2.1 

High Security 

High Acceptance 

OFF 

SW2.2 

Override rules disabled 

Override rules enabled 

OFF 

SW2.3 

 MDB v.4.0 Recycler 

Universal recycler 

OFF 

SW2.4 

Service Mode 

To work with a “Host 

Machine Controller” 

OFF 

 
 
RECYCLING CASSETTE CONTROLS: 
The Recycling Cassette controls are shown on the drawing below. 

RECYCLING CASSETTE DIP SWITCHES SETTING: 

 

Switch 

ON state 

OFF state 

Default 
Setting 

SW1 

Assign for  1000 VEF 

Assign for 500 VEF 

OFF 

SW2 

Cassette setup mode 

Normal operation 

OFF 

 
 
RECYCLING CASSETTE INDICATOR 

 

After power on Recycling cassette indicator shows control firmware version: 

F1 -> 24 

After initialization indicator shows number of bills inside of the recycling 
cassette.   
In case of an error it will start flashing showing consequently number of bills 
and one of the following error codes: 

E0h    

– there was a hardware error detected 

E1h    – 

no communication with Coin Changer. In this case device will emulate 

Coin Changer with 1 tube (5000 VEF or 10000 VEF). 

 

 

FEED/UNLOAD BUTTONS 

 

The  Feed  button  is  used  for  setting  a  Loading  mode.  This  mode  makes  the 
entered  bills  of  a  selected  denomination  to  be  loaded  into  the  recycling 
cassette. To cancel a loading mode, the Feed button must be pressed again. 
If  bills  do  not  enter  within  20  second  s,  the  loading  mode  will  be  canceled 
automatically. 
By  pressing  the  unload  button  one  bill  will  be  dispensed  from  the  recycling 
cassette through the entry channel. If the feed and unload buttons are pressed 
simultaneously  then  all  bills  will  be  unloaded  from  the  recycling  cassette  into 
the drop cassette.  

 

 

RECYCLING CASSETTE SETUP MODE 

 

Recycling  Cassette  setup mode allows user to adjust recycling cassette feed 
and  unload  levels  (maximal  number  of  bills  accepted  into  the  cassette  and 
number  of  bills  to  be  left  in  the  cassette  during  unload  operation 
correspondingly) without need of special equipment. In order to enter the setup 
mode set SW2 to ON. The cassette indicator will start blinking “FL”(Fill level) 
or  “UL”(unload  level)  and  the  set  level  consequently.  Press  FEED  button  to 
increase  level  and  UNLOAD  to  decrease  it.  In  order  to  switch  between  feed 
and unload settings press two buttons simultaneously. 
When setting is done set SW2 to OFF. Unit will switch to normal operation. No 
power cycling is necessary. 

DIP Switches

Unload button

Feed button

LCD display