6 - MAINTENANCE
Swing reduction unit oil
WARNING
Hot surface possible!
Wait for all components to cool before performing any operation.
Failure to comply could result in death or serious injury.
W0251A
Replace the swing reduction unit oil every
1000 h
(After
250 h
of operation in run-in period).
Lubricant:
H
YPOID
G
EAR
O
IL
E
XTREME
P
RESSURE
80W-90
.
Quantity:
2.2 L
(
0.6 US gal
).
1. Park the machine on a flat and level place. Stop the
engine, and remove the starter key.
2. Remove the oil gauge
(1)
and the fill plug
(2)
. Clean
the oil gauge with a neat cloth.
SMIL15CEX9564AA
1
3. Remove the lower panel
(3)
.
SMIL19CEX2632AA
2
4. Place a container with an appropriate capacity under
the upper structure frame. Remove the oil drain plug
(4)
to drain oil.
NOTE:
Draining oil requires a comparatively long time.
NOTE:
Check the condition of the drained oil. If foreign
objects, such as metal scrapings, are included, consult the
CASE CONSTRUCTION dealer.
SMIL15CEX9594AA
3
6-55
Summary of Contents for CX130C
Page 16: ...1 GENERAL INFORMATION 1 10...
Page 34: ...2 SAFETY INFORMATION SMIL20CEX1386HA 2 2 18...
Page 75: ...3 CONTROLS AND INSTRUMENTS Display SMIL18CEX0554FB 2 SMIL18CEX0534FB 3 3 29...
Page 112: ...3 CONTROLS AND INSTRUMENTS 3 66...
Page 134: ...4 OPERATING INSTRUCTIONS 4 22...
Page 150: ...5 TRANSPORT OPERATIONS 5 16...
Page 199: ...6 MAINTENANCE Bucket cylinder bottom pin one grease fitting SMIL18CEX0523AA 7 6 49...
Page 231: ...6 MAINTENANCE 8 Check that the tooth is securely fastened CA1C6271 3 6 81...
Page 240: ...6 MAINTENANCE 6 90...
Page 251: ...8 SPECIFICATIONS Working ranges SMIL20CEX1394HA 4 8 9...
Page 254: ...8 SPECIFICATIONS 8 12...
Page 278: ...9 ACCESSORIES 9 24...