DISTRIBUTION SYSTEMS - ELECTRICAL POWER SYSTEM
8.
Turn the load control knob until the ammeter
indicates the speci
fi
ed load. Keep the load for 15
seconds and read the voltmeter. Turn the load
control knob to OFF.
9.
Compare the test reading between the temperature
and the minimum voltage electrolyte data below.
21 °C (70 °F
) and above /
9.6 volts
16 °C (60 °F
) /
9.5 volts
10 °C (50 °F
) /
9.4 volts
4 °C (40 °F
) /
9.3 volts
-1 °C (30 °F
) /
9.1 volts
-7 °C (20 °F
) /
8.9 volts
-12 °C (10 °F
) /
8.7 volts
-18 °C (0 °F
) /
8.5 volts
10.
If the test result is equal to or more than the voltage
shown, the battery is in good condition.
11.
If the test result is less than the voltage shown,
discard the battery.
1 04/05/2005
A.30.A / 96
Summary of Contents for 435
Page 1: ...REPAIR MANUAL 435 445CT 445 6 75491 1 04 05 2005 ...
Page 3: ...INTRODUCTION 6 75491 1 04 05 2005 1 ...
Page 15: ...INTRODUCTION bs04e020_1 4 6 75491 1 04 05 2005 13 ...
Page 16: ...INTRODUCTION bs04e021_1 5 6 75491 1 04 05 2005 14 ...
Page 19: ...REPAIR MANUAL DISTRIBUTION SYSTEMS 435 445CT 445 39702 1 04 05 2005 A ...
Page 86: ...39703 1 04 05 2005 A 10 A 66 ...
Page 104: ...39704 1 04 05 2005 A 12 A 18 ...
Page 126: ...39705 1 04 05 2005 A 16 A 22 ...
Page 127: ...DISTRIBUTION SYSTEMS A ELECTRICAL POWER SYSTEM 30 A 435 445CT 445 39706 1 04 05 2005 A 30 A 1 ...
Page 237: ...DISTRIBUTION SYSTEMS A LIGHTING SYSTEM 40 A 435 445CT 445 39707 1 04 05 2005 A 40 A 1 ...