background image

Installation

Instructions

c

cascade

W

corporation

For Technical Support . . .   

To Order Parts . . .

 

Call: 1-800-227-2233 

Fax: 1-888-329-8207 

  Call: 1-888-227-2233 

Fax: 1-888-329-0234

  Internet: www.cascorp.com 

  Internet: www.cascorp.com

  Write: Cascade Corporation, PO Box 20187, Portland, OR 97294 

  Write: Cascade Corporation, 2501 Sheridan Ave., Springfield, OH 45505

TFC

 Raymond 

(Model 4150/4250)

Wire Connection Guide

A

7
4

B

AC2572.eps

TFC™ Components

Voltage Converter Kit

(Part No. 6816341)

Voltage Converter Fuse

Fuse, 2A

Fuse, 2A

(+) 36V

TS1-4

Constant Power

Distribution

Board

TS1-2

(-) Ground

Distribution 

Board

TS1-6

(+) at Key-Up

Key Power Relay Kit 

– 36V

(Part No. 6851614)

1

2

3

This manual provides installation instructions for connecting 

Cascade TFC™ wiring to a Raymond truck, model 4150/4250.  

Connect the Relay (fused) Position A wire to the Distribution 

Board Position "TS1-6" (+) voltage at key-up.

Connect the ground wire of the voltage converter and relay 

Position B to the Distribution Board Position "TS1-2" (-) 

ground.

Connect the positive fused wire of the voltage converter 

to the Distribution Board Position "TS1-4" (+) 36V Constant 

Power.