Raymond
(Model 4150/4250)
Wire Connection Guide
A
7
4
B
AC2572.eps
TFC™ Components
Voltage Converter Kit
(Part No. 6816341)
Voltage Converter Fuse
Fuse, 2A
Fuse, 2A
(+) 36V
TS1-4
Constant Power
Distribution
Board
TS1-2
(-) Ground
Distribution
Board
TS1-6
(+) at Key-Up
Key Power Relay Kit
– 36V
(Part No. 6851614)
1
2
3
This manual provides installation instructions for connecting
Cascade TFC™ wiring to a Raymond truck, model 4150/4250.
1
Connect the Relay (fused) Position A wire to the Distribution
Board Position "TS1-6" (+) voltage at key-up.
2
Connect the ground wire of the voltage converter and relay
Position B to the Distribution Board Position "TS1-2" (-)
ground.
3
Connect the positive fused wire of the voltage converter
to the Distribution Board Position "TS1-4" (+) 36V Constant
Power.