684948-R7
1
T
GA0170.eps
Truck Relief Setting
2000 psi (140 bar) Recommended
2300 psi (160 bar) Maximum
Truck Flow Volume
➀
Min.
➁
Recommended Max.
➂
4 GPM
7 GPM
10 GPM
35E, 45E
(15 L/min.)
(26 L/min.)
(38 L/min.)
➀
Cascade E-Series QFM
™
Push/Pull is compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid
is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
➁
Flow less than recommended will result in reduced mechanism
speeds.
➂
Flow greater than maximum can result in excessive heating,
reduced system performance and reduced hydraulic system life.
Carriage Mount Dimension (A)
ITA (ISO)
Minimum Maximum
Class II
14.96 in. (380.0 mm) 15.00 in. (381.0 mm)
Class III
18.68 in. (474.5 mm) 18.74 in. (476.0 mm)
A
GA0028.eps
GA0094.eps
RUCK REQUIREMENTS
Pull/Retract
OR
Sheet-Sav
™
Engage
OR
Gripper Down
Tilt Forward
Hoist Up
Auxiliary Valve Functions
Check for compliance with ITA (ISO) standards:
WARNING:
Rated capacity of the truck/
attachment combination is a responsibility
of the original truck manufacturer and may
be less than that shown on the attachment
nameplate. Consult the truck nameplate.
Carriage
Clean and inspect carriage
bars for damage. Repair any
damaged notches.
Tilt
Back
WARNING:
The QFM™ Push/
Pull requires forks to support the
attachment and load. Forks up to
1.8 in. (45 mm) thick and 40-46 in.
(1015-1168 mm) long can be used. 42 in.
(1066 mm) forks with bottom taper are
recommended. Forks over 1.5 in. (38
mm) thick require a spacer kit. Sideshifter
components (if equipped) must not protrude
in front of carriage bars.
Push/Extend
OR
Sheet-Sav
™
Release
OR
Gripper Up
Hoist Down