47
004778320 - 16/07/2020
ENGLISH
12.2 “ECO MODE” SAVING FUNCTION
By enabling this function, the stove is turned off when the desired room temperature is reached. If this function
is not enabled, the stove modulates its operation to maintain the desired temperature while consuming as little
as possible.
The “Eco Mode” function is only available in configuration 1.
To enable/disable this function:
a) Use the arrow keys to go to the set-up menu and press the
key;
b) Select the password “7” with the
key and confirm with the
key;
c) select the submenu
[7]
and confirm with the
key.
d) Set one of the following values with the
and keys:
Eco
→
It enables the “Eco Mode” function
Off
→
It disables the “Eco Mode” function
e) Press the key
to confirm the set data.
12.3 RE-IGNITION DELTA FUNCTION
The re-ignition delta is the number of degrees below the switch-off temperature beyond which the stove
automatically switches on again. For example, if the stove is set to switch off at 20°C (Eco Mode active) and we
set a “Re-ignition delta” of 4°C, the stove will turn back on when it detects a temperature lower than or equal to
16°C.
To change the value of the re-ignition delta:
a) Use the arrow keys to go to the set-up menu and press the key;
b) Select the password “7” with the
key and confirm with the
key;
c) Select the submenu
[8]
and confirm with the
key;
d)
The value will flash; modify it with the
and keys (
0.5 ... 5.0°C
);
e) Press the key
to confirm the set data.
12.4 SWITCHING ON AGAIN AFTER A BLACK-OUT
In the event of a power failure, the stove will automatically switch back on, verifying the safety conditions, when
the power supply returns.
12.5 “KEYPAD LOCK” FUNCTION
With this function, it is possible to lock use of the control panel to avoid accidental changes.
To enable/disable this function:
a) Use the arrow keys to go to the set-up menu and press the
key;
b) Select the password “7” with the
key and confirm with the
key;
c) Select the submenu
[10]
and confirm with the
key.
d) Set one of the following values with the
and keys:
“
Off
”
→
Keypad lock deactivated
“
Lo
”
→ Only the on/off key remains enabled
“
Hi
”
→
Keypad lock activated
e) Press the
key to confirm the data entered.
12.6 ANTI-FREEZE FUNCTION
(in configuration 1 only)
A minimum temperature can be set below which the stove will switch on (outside the set time bands and only of
the timer is enabled). To modify the ”antifreeze” temperature value:
a) Use the arrow keys to go to the set-up menu and press the
key;
b) Select the password “7” with the
key and confirm with the
key;
c) Select the submenu
[9]
and confirm with the
key;
d)
The value will flash; modify it with the keys
and (
OFF
;
3...20°C
);
e) Press the
key to confirm the data entered.