background image

3

C

ANDELIER

MOUNTING RECOMMENDATIONS

Before mounting your Casablanca Candelier, read the following helpful recommendations. 
The location of the fan, air circulation, and fan size are all important factors to consider 
before installation. 

Location

Ceiling fans have practical uses in almost every room in your home, but the Candelier 
fi xture is intended for use in larger rooms. Keeping that principle in mind, we suggest you 
follow these mounting recommendations as you decide where to install your Casablanca 
Candelier.

•  For safety reasons, the fan blades must be a minimum of 7 feet above the fl oor. 

•  Do not install the fan in a doorway or above a swinging door.

•  In bedrooms, fans work best when mounted above the foot of the bed.

•  Over pool tables, be sure to provide plenty of clearance to avoid damage from 

pool cues. 

•  Do not install a fan close to or over a pool or spa. High humidity combined 

with corrosive gases will destroy the fi nish and warp the fan blades. 

GENERAL GUIDELINES

7' minimum

The Candelier is not designed to be mounted on a ceiling 
sloped greater than 30 degrees. Mount the Candelier 
Crossbar Hanging Bracket with the opening pointed either 
up or to the side, depending on installation. The Candelier 
canopy cover has been engineered to mount fl ush to the 
ceiling, with the canopy insert swiveling to accommodate 
mildly sloped ceilings.

Blades must be a 

minimum of 7 feet 

above the 

fl

 oor

Down 

Rod

Maximum 

angle 30º

This slope is less than 30º.

It is OK to install your fan.

This slope is 30º.  This is the 

maximum slope that will allow the 

fan to hang straight down.  It is OK 

to install your fan.

This slope is more than 30º.  Your 

fan will not hang straight down. 

Specialized installation is required.

SLOPED CEILING INSTALLATIONS

STANDARD CEILING REQUIREMENTS

 

Ceiling Height 

Pole Length

 9' 

0" 

Standard

 9' 

6" 

Standard

EXAMPLE 3

EXAMPLE 2

EXAMPLE 1

LAG SCREWS

Summary of Contents for Candelier

Page 1: ...e CANDELIER OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS CONTENTS 1 INTRODUCTION 2 Before You Start 2 Safe Use 2 MOUNTING RECOMMENDATIONS 3 General Guidelines 3 Sloped Ceiling Installations 3 FAN I...

Page 2: ...in lengths from 12 inches to 117 inches Ask your authorized Casablanca dealer for details This ceiling fan requires a grounded electrical supply of 120 VAC 60 Hz and a minimum of 15 amp circuit The m...

Page 3: ...a fan close to or over a pool or spa High humidity combined with corrosive gases will destroy the finish and warp the fan blades GENERAL GUIDELINES 7 minimum The Candelier is not designed to be mounte...

Page 4: ...ly to a structural member of the ceiling It cannot be mounted directly to the outlet box Step 1a Hold the crossbar hanging bracket up to the ceiling Use a pen or pencil to mark screw placement through...

Page 5: ...n screws until they are secure against the ceiling Option 2 Using Sheetrock Anchors Install sheetrock anchors through the holes in the canopy bracket Tighten anchors until they are secure against the...

Page 6: ...thumb on the end of the cross bolt Insert the cross bolt until its flat end is flush with the downrod adaptor tube Re attach the nut and tighten firmly with 7 16 wrench NOTE Be careful not to cut or...

Page 7: ...wires are different from those described above consult an electrician Step 6b After connecting wiring slide the canopy cover up and into place Make sure the canopy cover tabs are properly aligned with...

Page 8: ...system Use extreme caution when handling flicker bulbs NOTE The Candelier flicker bulbs are extremely fragile and should be handled with care Step 8a To install or replace the halogen bulbs first rem...

Page 9: ...a numbered socket where the candle belongs on the Candelier fixture Candles and sockets are numbered for the width and height of each candle The colors will vary Carefully lower each candle over the...

Page 10: ...wall control operation is reversed fan switch controls lights and light switch controls fan turnoff the power at the breaker or fuse panel then swap the two W 32 black white stripe wires INTELI TOUCH...

Page 11: ...level of speed turn the fan on by pressing FAN less than one second To lower speed turn fan off the non by pressing and holding the FAN button until the desired speed is reached When the fan is on yo...

Page 12: ...lied for added protection and beauty For painted and high gloss blades surface smudges or an accumulation of dirt and dust can be removed easily using a mild detergent and slightly dampened soft cloth...

Page 13: ...tightly to the ceiling and the downrod assembly is secured firmly The downrod is attached to the downrod base too loosely Make sure all the screws are securely tightened Fan is noisy during operation...

Page 14: ...ested and found to comply with the limits for a class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a...

Page 15: ...430 9694 IHO SHINGLE SPRINGS 95682 JOHN ROZOWSKI CONST 530 677 3850 IHO SIMI VALLEY 93065 FANTASTIC FAN SERVICE 800 800 3871 IHO SOUTH LAKE TAHOE 96150 TAHOE POOL SERVICE 530 541 4958 FFS TARZANA 913...

Page 16: ...FS MINNEAPOLIS 55422 LEO S ELEC SALES SVC 763 546 5625 IHO STATE CITY ZIP SERVICE CENTER NAME PHONE TYPE MINNESOTA CONT D MONTICELLO 55362 LITTLE MOUNTAIN LIGHTING 763 295 5483 FFS ROCHESTER 55904 THO...

Page 17: ...UX FALLS 57105 LAMPS AND SHADES INC 605 332 6680 FFS STATE CITY ZIP SERVICE CENTER NAME PHONE TYPE TENNESSEE BRENTWOOD 37027 SUNSHINE ELECTRICAL 615 371 9383 IHO MARYVILLE 37803 BEN SNYDER 865 385 130...

Page 18: ...18...

Reviews: