SEND SIGNAL

LED

VERSA•TOUCH 2 OPERATION

Fan Control

To start the fan. Press the selected speed button to run the fan at the desired speed.

LO=Low speed    MED=Medium speed     HI=High speed

To turn off the fan. Press the 

FAN OFF

  button.

Airflow Direction

To reverse the airflow press the 

REVERSE

 button. Reverse operates at any speed whether fan

is on or off. The fan returns to its set speed after reversing.

Light Control

Turn the light on or off independently from the fan by pressing the 

LIGHT

 button.  Keep

pressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from
‘bright’ to ‘dim’ over approximately 8 seconds. This sequence will reverse the light when it
reaches the brightest or dimmest level if you continue to hold the 

LIGHT

 button. Release the

button when the desired level is reached.

Auto Resume

Quick (pressing less than 0.7 seconds) on/off operation of the 

LIGHT 

button maintains the

desired brightness level set previously.

VERSA•TOUCH 2 

 IF FAN DOES NOT WORK

If the fan is not functioning after installation:
Step 1.

 Check to make sure that batteries are installed correctly

in the control.

Step 2.

 Turn the power off to the fan (from the circuit breaker)

for at least 5 seconds.

Step 3.

 Turn the power back on (at the circuit breaker) and push

the Hi, Med, and Low buttons–in that order–within 20 seconds.

Step 4.

 The fan should now function properly.

VERSA•TOUCH 2 

 CHANGING FREQUENCY SETTING

You will only have to change the dip switch settings in the remote if
you are using more than one fan in the same area and want to control
them separately.

Step 1.

 At the circuit breaker or fuse box, turn the power off for the fan

you want to change.

Step 2.

 Open the battery door of the Versa•Touch control and remove

the batteries.

Step 3.

 Change the dip switch settings, assuring that they are different

from the previously installed Versa•Touch fan.

Step 4.

 Re-install the batteries and the battery door on the control.

Step 5.

 At the circuit breaker or fuse box, turn the power back on for

the fan whose frequency you are changing.

Step 6.

 Within 20 seconds of restoring power, push the Hi, Med, and Lo

buttons (in that order).

Note:

 All fans leave the factory set to ‘00000’.

WITHIN 20 SECONDS OF
TURNING THE FAN ON,
PRESS IN THIS ORDER TO
SET NEW FREQUENCY:

1. HI
2. MED
3. LO

1

2

3

CIRCUIT BREAKER

OR FUSE BOX

PRESS IN THIS ORDER TO SET NEW
FREQUENCY:
1. HI      2. MED      3. LO

DIP SWITCH

SET TO ‘01001’

DIP SWITCH

SET TO ‘10000’

VERSA•TOUCH 2

CONTROL

(BACK)

Note:

 You may want to label your controls to

assure you do not mix them up.

WARNING: Do not turn the power off at the circuit breaker,
then back on, for the previously installed Versa•Touch 2
fan(s), as you may inadvertantly change the frequency set-
tings for it as well.

LO

MED

HI

LIGHT

FAN

STOP

REVERSE

1

2

3

2

Summary of Contents for C CasablancaCAPISTRANO

Page 1: ...T INTRODUCTION 1 MOUNTING RECOMMENDATIONS 2 PREPARATION INSTRUCTIONS 3 FAN INSTALLATION 4 CONTROL FEATURES 3 SPEED OPERATION 10 TROUBLESHOOTING 12 VERSA TOUCH 2 13 TROUBLESHOOTING 15 BEFORE YOU START...

Page 2: ...vide sufficient clearance for the blades In bedrooms fans work best when mounted above the foot of the bed Over pool tables be sure to provide plenty of clearance to avoid damage from pool cues In low...

Page 3: ...ided with the outlet box ADDITIONAL HARDWARE 21 4 x 8 32 ROUNDED HEAD SCREW 2 FLAT WASHER 2 1 x 8 32 ROUNDED HEAD SCREW 2 PERMA LOCK HARDWARE Casablanca CAPISTRANO DOWNROD BALL ASSEMBLY ALLEN SET SCRE...

Page 4: ...EW 4 OUTLET BOX MOUNTING HARDWARE Note On sloped ceilings align the canopy opening towards the top or room peak Proceed with installation as follows Step 1 Route the wires from the ceiling outlet box...

Page 5: ...e the canopy opening CAPPED BLUE D1 OPTION WIRE ON 3 SPEED ONLY FOR INDEPENDENT W 80 LIGHT CONTROL PIN SLOT BALL Casablanca CAPISTRANO CANOPY HATCH INSTALLATION Step 5 Tuck the wires into the canopy w...

Page 6: ...the blade holder mounting holes in the fan motor the dummy switch housing must be removed Take out the two 5 32 X 9 32 screws secur ing the dummy switch housing and remove Put the two 2 screws aside...

Page 7: ...lade holder securing it with the four blade screws provided Using the screwdriver tighten securely by hand only BLADE SCREW 4 PER BLADE BLADE BLADE HOLDER BLADE INSTALLATION Step 11 On the flywheel re...

Page 8: ...REMOVED IN STEP 8 5 32 X 9 32 2 SWITCH HOUSING CONNECTOR SOCKET MOTOR CONNECTOR PLUG 3 SPEED SWITCH HOUSING AND CAP ASSEMBLY CAP SCREW 8 32 X 3 8 2 Note Save these two screws they will be used in Ste...

Page 9: ...ng Tighten securely by hand only INSTALLING THE SWITCH HOUSING CAP Step 16 Line up the two inner clear ance holes in the cap with the two threaded holes in the switch mounting plate standoffs Step 17...

Page 10: ...ght option wiring To install a W 40 wall control in place of an existing wall switch follow the instructions on the W 40 package Note No rewiring is required if the fan is replacing an existing light...

Page 11: ...ur 4 different speed settings No light fixture is used Set the FAN pull chain switch to the HIGH speed setting No changes in household or fan wiring are required The fan may be turned ON and OFF by th...

Page 12: ...k all wire connections making sure the power is turned off during this inspection Check that reverse switch is not set in center of throw FAN WOBBLES OR SHAKES Be sure canopy pin is properly set into...

Page 13: ...ONTROL BRACKET ROCKER TYPE LIGHT SWITCH SWITCH COVER PLATE Wall Installation Step A Locate a 2x4 wall stud in a convenient location Step B Orient the control bracket as shown over the 2x4 stud Step C...

Page 14: ...i Med and Low buttons in that order within 20 seconds Step 4 The fan should now function properly VERSA TOUCH 2 CHANGING FREQUENCY SETTING You will only have to change the dip switch settings in the r...

Page 15: ...de screws and or the light bulb s OPERATION Tighten canopy screws and mounting plate assembly Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have fal...

Page 16: ...r 188mm x 20mm Direct Drive Blade Span With 45 or 53 Blade Pitch 16 No of Blades 5 Technology 3 Speed Versa Touch2 W 72 Airflow 6 691 cfm Electricity Use 89 watts Airflow Efficiency 75 cfm watt Perfor...

Reviews: