background image

 

Summary of Contents for SW II Series

Page 1: ...2 ...

Page 2: ...RATIONS 8 1 Simple Weighing Mode 8 2 Weighing with Tare 8 3 Changing Unit of Weight 9 4 Hold Function 9 5 Comparator Function 10 6 Counting Function 11 7 Setup Mode 13 8 Interface in Detail 15 BATTERY MAINTENACE 17 ERROR MESSAGE 17 SPECIFICATIONS 18 3 ...

Page 3: ...4 ...

Page 4: ...5 ...

Page 5: ...th outstanding performance Your special departments can enjoy these high quality reliable CAS products We believe that your needs will be satisfied and you will have proper reliability This manual will help you with proper operation and care of the SWΙΙ Please keep it handy for future reference NAMES AND FUNCTIONS OVERALL VIEW 6 ...

Page 6: ...el the weight of tare Used to change the unit of weight and shown as following sequence on the display kg WL on or off PCS kg Used to select and hold or unit conversion function Used to convert the unit of weight Used to make the weight of commodity stable This weight is average value 7 ...

Page 7: ... 000 under the empty platter 1 Simple Weighing Mode Place a commodity on the platter Remove the commodity from the platter 2 Weighing with Tare TARE means the weight of container being used for a commodity TARE key function is to subtract the weight of the container from full weight loaded Place a container on the platter Press the key Place a commodity into the container then the display will sho...

Page 8: ...ll show the 0 000 3 Changing Unit of Weight Press the and key You may select kg lb or oz as the unit of weight 4 Hold Function When the weight is unstable press the key Fn will be displayed Press the key Then hOLd will be displayed twice Then average value will be show twice And the hOLd function will be removed automatically 9 ...

Page 9: ...ey If you want to move to next digit you can go by pressing key If you set up HIGH limit you can go out by pressing key and End message on the display If you set up HIGH limit and LOW limit incorrectly Err will be shown on the display Then you may need to set it up again For example setting LOW LIMIT 2 990 kg and HIGH LIMIT 1 990 kg this is incorrect setting because HIGH limit is lower than the LO...

Page 10: ...y twice to go to sample unit selection mode Press key to select the number of sample unit You can select 10 20 50 100 200 or 500 as a sample unit If you select P 10 as a sample unit then please put 10 sample units on the scale Then press key to set sample units Put all of commodities you wish to count and then check the number of pieces on display Remove all of commodities from the scale 11 ...

Page 11: ...ut 20 sample units on the scale Then press key to set unit weight Put all of commodities you wish to count and then count the number on display Remove all of commodities from the scale Remove the tare from the platter Press Tare key to exit from tare function When you try to set the number of sample unit at the stage the display may show LACK message shortly The result of counting may be incorrect...

Page 12: ...f RS 232C communication Make sure that power is OFF While pressing the key turn on the scale The display shows U SEt When you release the key it will show you the current settings You can change by pressing the key Please refer to TABLE 1 Press the key to save the setting Then the display will show RS St and turn to RS 232C setting Default setting is RS St You can change by pressing the key Please...

Page 13: ...ISPLAY DESCRIPTION Do not use a back light Use back light when you put on the weight Backlight Use back light always If weight is stable transmit the data Transmit the data contiunally RS 232C Communicate with PC 14 ...

Page 14: ...function is helpful to understand RS 232C Communication user setting The following is the communication information of RS 232C RS 232C Port Connection 8 BITASCII code None parity 1 stop bit baud rate 9600 USB INTERFACE Device 15 ...

Page 15: ...art of heading STX 02h Start of text STA S 53h U 55h S Stable U Unstable SIGN 2Dh SP 20h Sign of the weight data W5 W0 Weight data UN1 UN2 KG LB Unit of Weight BCC Block check character exclusive or ETX 03h End of text EOT 04h End of transmission COMMAND DC1 0X11 SCALE PC DATA FORMAT 16 ...

Page 16: ...scription Solution The Z Err occurs when a current zero point has shifted from the last span calibration Please call your CAS dealer When HIGH and LOW limit are set as the same or above maximum capacity it still shows Err message Please reset the maximum and minimum capacity The d Err message will be shown when HIGH and LOW limits of comparison functions are set as inadequate unit value Please res...

Page 17: ...digit LCD Symbols STABLE ZERO TARE g kg lb oz Low Battery HI OK LO PCS Keys ZERO UNIT TARE HOLD MODE FUCTION Functions Weighing Hold Unit Conversion Counting Counting Sample Range 10 100 200 500 Weight Comparison Function hi ok low Backlight ON OFF Control Function Dimension s 250 W x 281 D x 110 H mm 984 W x 111 D x 43 H inch Platter size 226 W x 187 D mm 88 97 W x 73 62 D inch Weight 1 8 kg Powe...

Page 18: ...19 ...

Page 19: ...20 ...

Reviews: