background image

 

3

 

Summary of Contents for PR-C series

Page 1: ...3...

Page 2: ...digit unit 9 4 Delete 10 5 SMPLsampling 10 6 UWS single weight entering 10 7 Weight Quantity accumulation 10 8 Accumulative display 11 9 Accumulative clear 11 10 Print 11 11 Set up Hi limit 11 12 Set...

Page 3: ...4 Precautions...

Page 4: ...5 Precautions...

Page 5: ...te a power supply for the balance When a power supply for the balance is turned on and off a Power supply key shall be used and nothing shall be allowed to be placed on a platter This balance has a ch...

Page 6: ...It displays an accumulated quantity or a measured quantity up to 6 digits 2 Display symbols Symbol Detailed content Net weight mode Zero point display Being in a stable condition Battery being in a ch...

Page 7: ...nternal setting internal setting press Go to RS232 setting Under internal setting internal setting press Go to checking setting Turn on Zero Turn on Tare Turn on Enter delete Accumulative delete Turn...

Page 8: ...00ms during each hour COUNT VerX are shown continuously Ex COUNT 30kg Ver0 Operating functions explanation 1 Zero Step Operation 1 Click zero point At a zero point the total weight is displayed as O 2...

Page 9: ...tinuously displayed in the display window 6 UWS single weight entering Step Operation 1 a Upon inputting values of weight unitweight 0 will be continuously displayed in the display window b Upon input...

Page 10: ...continuously displayed in the display window it will return to the weight setting a second later 10 Print Step Operation 1 Upon outputting using RS232 printing will be executed by RE232 method by cli...

Page 11: ...on In the display window originalvalue SEtLo 0 will be continuously displayed b When keys are clicked originalvalue SEtHi 0 will be continuously displayed in the screen c After inputting values click...

Page 12: ...ontinuously displayed in the display window 4 Check while clicking the key and return to the weight measurement Example 1 a b c d e 02210 a Backlight setting Function available only in LCD 0 Automatic...

Page 13: ...ntering value RSSET will be continuously displayed in the display window 4 Check after clicking the key and return to the weight measurement Example 1 a b c d e 11111 a Baud rate setting 0 4800 1 9600...

Page 14: ...ll be continuously displayed in the display window 4 Check after clicking the key and return to the weight setting Example 1 a b c d e 00010 a Set up check alarm type 0 Weight 1 Quantity b Set up stab...

Page 15: ...3 Upon clicking the the screen will return to the weight setting again Error message Error code Cause Battery charging required B Err Emergency battery charging required oL Checking required to see if...

Page 16: ...5g 1g External Resolution 1 30 000 Internal Resolution 1 600 000 Display Type LED Weight Units Kg g lb oz Operating temperature 0 40 Power AC 220 240 50 60Hz Pb Battery 6V 4Ah Battery life 100hrs Dime...

Page 17: ...18 MEMO...

Page 18: ...19 4...

Reviews: