Instruction manual
IT600-1
Non-contact Infrared Thermometer
Instruction manual
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
Attention
Introduction
Compact, rugged and easy to use. Just aim and push the button,
read current surface te-mperatures in less than a second.
Safely me-asure surface temperatures of hot, hazardo-us or
hard-to-reach objects without contact.
How it works
Infrared thermometer measure the surface temperature, of an object. The units optical system sense the object's
emitted energy with different wave, length. It is collected and focus onto a detector. The unit s electronics system
translated the information into a temperature reading which is displayed on the unit.
Quick start instruction
Cautions
Infrared thermometer should be protected for the
following:
-EMF (electro-magnetic fields) from arc weld-ers, induction heaters.
-Thermal shock (cause by large or abrupt ambi-ent temperature
changes allow 30 minutes for unit to stabilize before use).
-Do not leave the unit on or near objects of high temperature.
Red laser point only position the general direction the
detection hole is the main parts measure the temperature
2. Locating a hot spot :
To find a hot spot aim the thermometer outside the area of interest, then scan across with
up and down motions unitl you locate the hot spot.(please turn on the laserto for accurate measuring)
(3)-(6) key functions :
press 3 key, LCD subdis-play blinks MAX-MIN-DIF-AVG-HAL-LAL-STO segment
(only main display means normal measuring mode) press 4 key to enter.
a. MAX: measuring maximum temperature
b. MIN: measuring minimum temperature
c. DIF: Basic on the reading before press 4 key, compute the difference of current reading.
d. AVG: measuring average temperature
e. HAL: high temperature alarm- when selected HAL, press 5 keys to set high temperature alarm trigger and
confirmed by pressing 4 key. When reading over trigger, LCD display HI icon with BiBi audio sounds.
f. LAL: low temperature alarm--when selected LAL, press 5 keys to set low temperature alarm trigger and confirmed
by pressing 4 key. When reading over trigger, LCD display LOW icon with BiBi audio sounds
g. STO: data storage- when selected STO, lock & DATA & 1- indicator will shown when press 4 key.
After temperature read out press 6 key to store, then 2- memory unit will be shown.
There 12 groups memory unit available. To recall the stored data in normal measuring mode by press-ing 6 key,
remove all data by pressing 6 keys for 2 secretary.
h. EMS: Emissivity setup--press 5 keys for emissivity settings, press 4 key to save setup and back to normal status.
(7) LCD
(8) Battery door clip
(9) Battery door: When replace battery door, please press battery door clip and pull the battery door.
(10) Clesius / Fahrenheit switch: Please open battery and push the slide switch for con-vertsion Maintenance
1) Lens cleaning: Blow off lose particles using clean compressed air.
Gently brush remaining debris away with a moist cotton cloth.
2) Case cleaning: Clean the case with a damp sponge/cloth and mild soap.
Note:
1) Do not use solvent to clean lens.
2) Do not submerge the unit in water.
3. Diagram description
(1) Trigger: When turn on LCD display VER XX
software version for 1 sec. And turn to di-splay
reading with SCAN icon. Release the trigger,
display reading with HOLD icon for 7 sec. Built
in auto power off in 30sec.
(2) Laser / back light button: when back light turn on ,
any operations will remain back lig-ht for
10 sec. LCD indicate on/off status.
Warning
Do not point laser directly at eye or indire-ctly off
reflective surfaces.
1.When take measurement, point thermome-ter toward the object to be measured and hold the yellow trigger.
The object under test should be larger than the spot size cal-culated by the field of view diagram.
2.Distance & spot size: As the distance from the object increase, the spot size of meas-uring area becomes larger.
(Figure 1)
3. Field of view: Make sure the target is larger than the unit's spot size. The smaller the tar-get the closer measure
distance. When acc-uracy is critical, make sure the target is at least twice as large as the spot size.
4. Emissivity: Most organic materials and pa-inted or oxidized surfaces have an emissiv-ity of 0.95 (preset in the unit).
Inaccurate readings will result from measuring shiny or polished metal surfaces. To compensate, cover the surface to
be measured with mas-king tape or flat black paint. Measure the tape or painted surface when the tape or painted
reach the same temperature as the material underneath.
Marterial
Emissivity
Marterial
Emissivity
Aluminum
0.30
Iron
0.70
Asbestos
0.95
Lead
0.50
Asphalt
0.95
Limestone
0.98
Basalt
0.70
Oil
0.94
Brass
0.50
Paint
0.93
Brick
0.90
Paper
0.95
Carbon
0.85
Plastic
0.95
Ceramic
0.95
Rubber
0.95
Concrete
0.95
Sand
0.90
Copper
0.95
Skin
0.98
Dirt
0.94
Snow
0.90
Frozen food
0.90
Steel
0.80
Hot food
0.93
Textiles
0.94
Glass(plate)
0.85
Water
0.93
Ice
0.98
Wood
0.94
Specifications
IT600-1
Temperature range
-50 to 600°C (-58 ~ 1112°F)
Accuracy
100°C (212°F) ~ 600°C (1112°F) ±2°C or ±2%
0°C (32°F) ~ 100°C (212°F) ±2°C or ±2%
-50°C (-58°F) ~ 0°C (30°F) ±3°C or ±3%
whichever is greater
Repeatability
1% of reading or 1℃
Response time
500mSec, 95% response
Spectral response
8 - 14 um
Emissivity
0.1 ~ 1.00 adjustable (pre-set 0.95)
Ambient operating range
0 ~ 40°C (32 ~ 104°F)
Relative humidity
10-95% RH noncondensing, 8 ~ 30°C (86°F)
Storage temperature
-20 ~ 60°C (-4 ~ 140°F) (without battery)
Weight/Dimensions
170g / 175 X 100 X 49mm
Power
9V Alkaline or NiCd battery
Battery life (Alkaline)
Laser Models : 12 hrs
Distance to Spot Size
12 : 1
A measuring reading
B measuring unit
C laser on icon
D back light on icon
E battery power icon
F scanning icon
G data hold icon
H mode indicator
I data storge / read icon
J low temperature alarm icon
K hight temperature alarm icon
LCD display
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
(Figure 2)
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
(Figure 3)
(Figure 4)
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
적색 레이저 조준
검출
Red Laser Point
Detection
2
SET
STO/CAL
LASER
BACKLIT
MODE
1
7
5
6
5
8
4
3
9
A
B
C
D
E
F
G
C
F
HOL D
SCA N
LOW
HIGH
DATA
H
J
I
K
반사 에너지
전달 에너지
방사 에너지
물체
CAS BLDG., 1315, YANGJAE-DAERO,
GANGDONG-GU, SEOUL, KOREA
www.cas.co.kr
1577-5578