background image

11

10

Reason

Battery damaged

Battery contact loosed

Low battery Min. Capacity

OFF/ON  Åbuttun damaged

TARE  Åbuttun damaged

The recharger damaged

The recharger isn’t
plugged ready

The load is unstable

Loadcell cable damaged

The scale in damp
environment for a long time

No enough time for heating
the scale after turn on

Put the scale on ground for
too long time

The scale isn’t hung properly

Battery damaged

Outlet damaged

Receiver window is too dirty

low battery of controller 

Solution    

Check battery  

Tighten the contact

Recharge the battery

Check&clean the buttun

Check&clean the buttun

Check the recharger

Insert plug again

Stablize the load

Check and replace loadcell

Put the scale in dry
environment

After turning on, heating 3-5
minutes.

Scale should be hung

Check the scale and sling

Replace battery

Replace the outlet

Check and clean

Replace controller battery

Troubleshooting  

Phenomenon

No display when
turn on

Display flash

Can’t trun on &off

Can’t tare

Recharge indicator
light can’t turn on

Display isn’t stable

The display don’t show
“0” when empty load

The error is large

Battery can’t recharge

Remote distance shorten 

Illustration

Waiting stable

Accumulated weight not exceed Min. Capacity

Accumumated times exceed, (can’t accumulate after 30times)

Accumulated weight exceed(can’t accumulate after 99999)

Ask if you really want to delete accumulated weight, in case

error deletion

Give up deletion

Confirm deletion

No any accumulated value (when you check)

Conversion, when you press SHIFt in controller

The voltage of current battery

Enter weight adjustment

Enter parameter adjustment

Enter voltage adjustment

Overload warning

Low battery warning

End, when parameter adjustment ready

Turn off

Display Message

Display

Summary of Contents for IE-1700

Page 1: ...2005 6 IE 1700 Electronic Crane Scale OWNER S MANUAL ...

Page 2: ...CONTENTS Safetyguide 4 Precaution 4 Productcharacteristics 4 Specification 5 Model 6 Sizeandnetweight 6 Operation 7 ElectricalPrincipleDiagram 9 DisplayMessage 10 Troubleshooting 11 Remotecontroller 12 ...

Page 3: ...tion Aluminum Die Casting Case high intensity hook and shackle special loadcell for safty installation High reliability Using high quality components on PCB circul board to insure long time stability Broad applicability 30mm high character display 25M distance eyeshot can be used in storage industry textile industry metallurgy industry etc Simply operation Check battery voltage automatically wirel...

Page 4: ...ate like this TARE Operation Display Illustration Press T on scale Press this key to deduct the weight of Press TARE on container while TARE light on the controlller scale will show the net weight of load Notice As crane scale deduct the weight of container automatically so it will show the net weight of load every time you needn t press this key to get net weight until you change the container or...

Page 5: ...rs this scale have recharging protection function long time recharging will not damage the battery TURN OFF Press OFF ON on scale 2 seconds Press OFF on controller 2 seconds Stable after 15minutes it show after 60minutes it turn off automatically Electrical Principle Diagram Control distance Control key Battery Load cell signal enlarges A D CPU LED or LCD display CHECK BATTERY Press OFF ON on scal...

Page 6: ...ung Check the scale and sling Replace battery Replace the outlet Check and clean Replace controller battery Troubleshooting Phenomenon No display when turn on Display flash Can t trun on off Can t tare Recharge indicator light can t turn on Display isn t stable The display don t show 0 when empty load The error is large Battery can t recharge Remote distance shorten Illustration Waiting stable Acc...

Page 7: ...CH Operation Display Illustration MR Current accumulation times M Current weight Rear four digit of current accumulated value Front four digit of current accumulated value MR Return to weigh Remote controller guide Lightness of display Operation Illustration F1 0 5 0 no display 1 Minimum light 5 Maxium light Default 2 HOLD Operation Illustration HOLD Hold the weight HOLD light on HOLD Convert to w...

Page 8: ...g Lb conversion Operation Display Illustration MR Un 0 kg lb light off HOLD Un 1 lb lb light on SEARCH OVERLOAD TIMES Operation Display Illustration MR CLEAR Display times of overload VOLTAGE DISPLAY Operation Display Illustration MR F1 Display show current voltage of the battery MR Return to weigh MEMO ...

Page 9: ...18 MEMO ...

Reviews: