CAS DC150-1 Instruction Manual Download Page 2

Digital Caliper  

Instruction manual

 

 

DIAGRAMMATIC SKETCH OF STRUCTURE

TECHNICIAL SPECIFICATIONS

Resolution

0.01mm

Measuring range(mm)

0-75, 0-100, 0-150, 0-200, 0-300

Error of indication(mm)

±0.02 (0-75, 0-100, 0-150, 0-200, 0-300)

Power

1.5V battery(LR44)

Measuring speed

1.5m/s

Working temperature

0 ~ +40

Relative humidity

80%

Storage temperature

-10 ~ +60

BRIEF ON MAINTENANCE

Troubles 

Possible 

Causes

Solutions

Flashing digits

Low voltage

Replace the battery

No Display

1. Low voltage

2. Poor contact 

1. Replace the  battery

2. Adjust and clean the battery seat

1. Fixed digits

2. “H.I.M.P” appear on the 

screen

Accidental trouble 

in circuit

Take out the battery and put it back 

after one minute

FUNCTIONS

1. With ON/OFF function.
2. With ZERO key for zero-setting at any position for incremental measurement.
3. mm/in key for mm/in conversion at any position.
4. With low voltage check function. It’ll flash at low voltage.

BATTERY REPLACEMENT

OPERATIONS

1. Preparation

(1) Dry the surface of the protective sticker (pls see Notes) and clean the 
     measuring surfaces.
(2) Loosen the locking screw and move the slider to check if the LCD display 
     and all the buttons work properly.

2. Measurement

(1) Press ON/OFF to switch on power.
(2) Press mm/ inch to select the desired unit system.
(3) Move the slider to make two outside measuring faces touch gently and press 
      Zero button to start measuring.

Measurements

Abnormal display(digits flashing or even no display) shows a flat battery and it 
should be replaced. 
1. Screw off the side screw on the battery cover and take out the button cell, 
    then put in a new button cell. 
2. ABS housing: Push out the battery cover outwards, then remove the battery 
    to replace a new one.

Note: 

the positive pole of the battery must face out. if the battery bought from 

market does not work satisfactorily (the power may wear down because of 
the long-term storage or the battery’s automatic discharge ect.), please do not 
hesitate to contact the supplier.

NOTES

1. The moving speed of the slider can’t excess 1.5m/s or 60inch/s.
2. Being the precision measuring instrument, the electronic digital caliper 
    should be prevented strike and drop to avoid losing precision during operation.
3. The indicator must be kept clean. Water and other liquids must be prevented 
    from entering it to avoid damaging its electronic parts.
4. The surface of the caliper can be cleaned with pure alcohol. 
    Never use acetone.
5. Don’t remove the data output interface cover when the data output is not use. 
    Never touch it with any metal parts for fear of damaging electronic circuit.
6. No voltage should be applied on any part of the indicator and never carve 
    it with an electronic pen for fear of damaging the electronic circuit.
7. Take out the battery if the indicator is not in use for a long time.

DC150-1

Instruction manual

1.Step Measuring Face   

2. Inside Measuring face 

3. Inside Measuring face    

4. Mm/in conversion key

5. Locking Screw   

6. LCD Display   

7. Depth bar   

8. Outside Measuring surface  

9. Slider 

 

10. On/Off key  

11. ZERO key      

12. Battery cover 

13. ON/OFF/ZERO key

CAS BLDG., 1315, YANGJAE-DAERO, GANGDONG-GU, SEOUL, KOREA