34
BCC Selection Mode
F36
●
0
BCC not used
1
BCC used
Data Transference count setting
F37
0
About 40 times/sec
1
About 30 times/sec
2
About 20 times/sec
●
3
About 15 times/sec
4
About 10 times/sec
5
About 5 times/sec
6
About 3 times/sec
Weight Unit selection (Communication)
F40
●
0
kg
1
g
2
ton
Average Display Setting Mode
F53
●
0
No operation.
1~99
Operating. (The higher the value, the slower the response time in
the weight shown on the display)
Steady LED Status Lamp Delay time setting
F54
●
0
No operation.
1~99
Operating. (Delay during 0.1 ~ 9.9sec, and LED lamp will be ON.)
Tension and Compression setting
F55
●
0
No operation. (JP1 switch OFF at main board)
1
Operating. (JP1 switch ON at main board and then must be re-
calibration.)