Usage (with the transmitter):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals B and C are Normally Open; Terminals
A and B are Normally Closed.
If you want to control a DC 12V lamp, do as following:
1) Connect the live wire of the AC
power supply to terminal “L / +”, and the neutral wire of the AC power supply to terminal “N / -“.
2) Connect terminal C to the positive pole of the DC power supply, connect terminal B to the positive pole of the DC lamp, and connect the negative
pole of the DC lamp to the negative pole of the DC power supply.
If you want to control an AC 220V lamp, do as following:
1) Connect the live wire of the AC
power supply to terminal “L / +”, and the neutral wire of the AC power supply to terminal “N / -“.
2) Connect terminal C to the live wire of the AC power supply, connect terminal B to one side of the AC lamp, and connect another side of the AC
lamp to the neutral wire of the AC power supply.
Setting different control modes (We have set the receiver as Toggle control mode before delivery. If you want to use other control modes,
do as following operation):
1) Setting control mode Toggle: Connect Jumper-2.
Control mode Toggle (with transmitter CV-12 or CB-12): Press -> On; Press again -> Off.
Press button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Press button 1 again: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Press button 2 again: Turn off relay 2 of receiver 1 (disconnect B and C, connect A and B), the lamp2 is off.
…
Press button 11: Turn on relay 1 of receiver 6 (connect B and C, disconnect A and B), the lamp11 is on.
Press button 11 again: Turn off relay 1 of receiver 6(disconnect B and C, connect A and B), the lamp11 is off.
Press button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnect A and B), the lamp12 is on.
Press button 12 again: Turn off relay 2 of receiver 6 (disconnect B and C, connect A and B), the lamp12 is off.
2) Setting control mode Momentary: Connect Jumper-1.
Control mode Momentary (with transmitter CV-12 or CB-12): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Release button 1: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Press and hold button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Release button 2: Turn off relay 2 of receiver 1 (disconnect B and C, connect A and B), the lamp2 is off.
…
Press and hold button 11: Turn on relay 1 of receiver 6 (connect B and C, disconnect A and B), the lamp11 is on.
Release button 11: Turn off relay 1 of receiver 6 (disconnect B and C, connect A and B), the lamp11 is off.
Press and hold button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnect A and B), the lamp12 is on.
Release button 12: Turn off relay 2 of receiver 6 (disconnect B and C, connect A and B), the lamp12 is off.
3) Setting control mode Latched: Disconnect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter CV-12 or CB-12): Press -> On, another relay Off; Press another button -> Off.
Press button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Turn off the other relays of receivers (disconnect B and C, connect A and B), the other lamps are off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Turn off the other relays of receivers (disconnect B and C, connect A and B), the other lamps are off.
…
Press button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnect A and B), the lamp12 is on.
Turn off the other relays of receivers (disconnect B and C, connect A and B), the other lamps are off.
4) Setting control mode Mom Toggle: Connect Jumper-1 and Jumper-2.
Control mode Momentary (Channel 1): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of receiver 1 (connect B and C, disconnect A and B), the lamp1 is on.
Release button 1: Turn off relay 1 of receiver 1 (disconnect B and C, connect A and B), the lamp1 is off.
Control mode Toggle (Channel 2): Press -> On; Press again -> Off.
Press button 2: Turn on relay 2 of receiver 1 (connect B and C, disconnect A and B), the lamp2 is on.
Press button 2 again: Turn off relay 2 of receiver 1 (disconnect B and C, connect A and B), the lamp2 is off.
…
Press button 12: Turn on relay 2 of receiver 6 (connect B and C, disconnect A and B), the lamp12 is on.
Press button 12 again: Turn off relay 2 of receiver 6 (disconnect B and C, connect A and B), the lamp12 is off.
Manual control terminals:
The receiver has manual control terminals, you can connect external devices, sensors, or manual switches to control the receiver.
1) Signal input:
You can connect external devices (with low level output signal) to terminals
“1”, “3”, the external device’s output signal can control the receiver.
When the external device outputs low level signal to terminal
“1” and “3“, turn on the relay1 (connect terminals B and C, disconnect terminals A and