![CARRON CAST IRON STOVE Installation And Operating Instructions Download Page 4](http://html1.mh-extra.com/html/carron/cast-iron-stove/cast-iron-stove_installation-and-operating-instructions_2564315004.webp)
Controlling the stove -
Setting the primary air supply (the inlet below the glass door)
air control – sliding the air control to the right will allow the maximum amount of air into
the stove, and cause the fire to burn quickly. Sliding it to the left will allow the minimum
of air into the stove, and the fire will burn more slowly, and give off less heat. Setting
the secondary air supply (the inlet above the glass door) air control – is the same
operation as above. These air supplies must be kept clear of blockages and regularly
checked.
If the stove goes out with fuel still in it, the air controls are set too low. Generally the
ideal setting is to have the primary inlet almost closed and the secondary inlet 1/2 open.
However this may vary depending on the flue draught and you will need to fine tune
these settings to suit your preferred burn rate. Should the stove overheat, shut down
the stove by ensuring the door and all inlets are closed. Operation with the air controls
or dampers open can cause excess smoke. The appliance must not be operated with
the air controls or dampers doors left open, except as directed in the instructions.
Cleaning the stove –
To ensure the performance of your stove is not affected, regular
cleaning is necessary. To clean, allow the stove to cool, then wipe with a soft damp
cloth. The throat plate should be removed and cleaned monthly along with checking the
door seals for damage.
Do not use any abrasive cleaning products, as they will damage the finish of the stove.
The window is self-cleaning due to the “air-wash” at the top of the door. The use of
damp fuels may cause staining of the window. After long periods of non-use it is
necessary to check the flue for blockages.
Emptying ashes –
ensure ashes are entirely cool before they come into contact with
plastic dustbins or bin-bags. It is important that ash does not build up to the extent that
it contacts the underside of the grate.
Precautions to note:
Carron stoves do not contain asbestos. However, please take care not to disturb any
existing asbestos when removing an old stove.
The stove is very heavy; move it with assistance.
Take care to ensure fire cement does not come into contact with skin.
In the unlikely event of a chimney fire, close the stove door and both air supplies,
evacuate the property immediately, and call the fire brigade. Do not attempt to
extinguish your stove.
Persistent fume emission should not occur if the product is properly installed and
operated. However, should this occur, take immediate action as follows:-
- ventilate the room
- extinguish the fire
- check the chimney/flue for blockages and clean if required
Seek expert advice if necessary.
The stove and flue pipe will become extremely hot during use; take care especially
when children or the infirm are present. Do not store flammable materials near to the
stove. Any combustible furnishings must be at least 500mm away.
Only use replacement parts supplied by the manufacturer and do not modify the stove
in any way.