4–5
T-378
4.4 Alarms
Alarm conditions where the EES becomes inoperable will initiate a 250 hour timer. After 250 hours, the unit will
shut down until the system is repaired by a qualified technician. Once the alarm condition is corrected, the EES
Service Light will go from Amber to Green and the timer will be reset. Refer to
.
Refer to
for a list of alarms and troubleshooting information.
1. From the Setup Screen, click on the AR-DOC tab.
2. Alarms can be read with the unit running or turned off, as long as battery power is hooked up.
Red: Active alarm
Blue: Alarm has been corrected
Green: Alarm has been cleared
Figure 4.6 ECM Service Tool - Alarms