Operational information

 

Five-minute compressor timeguard

 

This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by 
simultaneously pressing the FAN mode button and INCREASE TEMPERATURE (UP) button.

 

Heat/Cool set points (desired temperature)

 

A minimum difference of 2° is enforced between heating and cooling desired temperatures. This is done by allowing one 
setting to “push” the other, to maintain this difference. (Thermidistat Control is adjustable.) Builder’s thermostats are 
controlled by a single set point.

 

Equipment on indicators (Non-Programmable models)

 

When cooling equipment is ON, a COOL ON icon is displayed above the room temperature display. When heating equipment 
is ON, a HEAT ON icon is displayed above the room temperature display.

 

Equipment on indicators (Thermidistat Control)

 

When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool set point. While 
cooling equipment turn on is delayed by a staging or cycle timer, the triangle and the word COOL will flash. The same is true 
for the HEAT icon and its preceding triangle located under the heat set point. The 2 triangles are also used to indicate the state 
of the humidify and dehumidify outputs. See next section.

 

Humidify/dehumidify output on indicators (Thermidistat Control)

 

Within humidity select screen (selected by Humidity button and indicated by “hu” or “dhu” on clock display), the triangle 
under humidity set point will be on while humidify output is on. The triangle under dehumidify set point will be on while 
dehumidify output is active (turned off, because this output is reverse logic).

 

Auto changeover

 

When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode 
demand has existed for 20 minutes. If set point is changed, the 20 minute requirement is deleted. Auto changeover mode can 
be disabled. Builder’s and Standard Programmable thermostats are manual changeover.

 

Emergency heat mode

 

When thermostat is controlling a heat pump and emergency heat is selected, all Y signals are locked out, and W becomes 
energized upon a call for heat.

 

Smart Recovery (Programmable models)

 

With Smart Recovery selected, transition out of setback begins a fixed time period before selected recovery time and gradually 
adjusts room temperature so that the desired temperature will be achieved at selected recovery time. 

 

Room Temperature Offset (All models)

 

Room temperature may be deliberately offset by up to 5°F in either direction.

 

Maximum On/Off Deadband

 

Maximum sensed temperature difference between ON and OFF is 0.8°F for Builder’s thermostats and 0.6°F for all other 
models.

Summary of Contents for TSTATCCREC01

Page 1: ...COOL FAN POWE R BUILDERS NON PROGRAMMABLE THERMOSTAT DELUXE PROGRAMMABLE THERMOSTATS THERMIDISTAT INDUSTRY LEADING TEMPERATURE PLUS HUMIDITY CONTROL STANDARD PROGRAMMABLE THERMOSTATS DELUXE NON PROGRAMMABLE THERMOSTATS STANDARD NON PROGRAMMABLE THERMOSTATS Heat Off Cool Fan On Fan Auto next prog run off set Heat Off Cool Fan On Fan Auto ...

Page 2: ...Two set points 1 for heating and 1 for cooling Clean filter indicator Time limit adjustable Auxiliary heat indicator Heat pump models only Five minute compressor timeguard English Metric F C selection Installer adjustable Anticipator adjustment controls sensitivity cycles per hour Seven day programming with 4 time periods per day Hold function for temporarily overriding program schedule Outdoor te...

Page 3: ...r indicator Time limit adjustable Auxiliary heat indicator Heat pump models only Five minute compressor timeguard English Metric F C selection Installer adjustable Anticipator adjustment controls sensitivity cycles per hour Outdoor temperature sensing Optional on all models except non programmable AC Auxiliary heat lock out Heat pump and dual fuel models using outdoor sensor Fan activation automat...

Page 4: ... Deluxe Non Programmable Thermostat Controls Standard Non Programmable Thermostat Control 4 1 4 3 4 2 3 4 5 13 16 3 1 2 1 3 8 4 3 8 7 3 8 1 3 8 Mode Fan 1 18 37 2 75 4 25 4 783 4 37 1 12 3 05 3 05 1 0 t 3 05 3 05 1 35 3 05 3 05 1 35 4 75 3 25 HEAT COOL FAN POWER 4 75 3 75 1 75 Wireless Sensor Wireless Receiver Heat Off Cool Fan On Fan Auto 3 50 5 50 1 00 Heat Off Cool Fan On Fan Auto 3 50 5 50 1 0...

Page 5: ... set points Auto changeover can be disabled Clean filter reminder installer adjustable Permanent memory Programming days 7 day Programming periods 4 Wake Day Eve Sleep Hold function Copy previous day function Humidity display and control Thermidistat Control only Equipment On indicator Thermidistat Control only Vacation Programming Standard Programmable Models Temperature set point range 50 F 10 C...

Page 6: ...able Slimline Style TSTATCCPF101 Thermostat Auto Changeover single day programmable Flushmount style TSTATCCPF701 Thermostat Auto Changeover 7 day programmable Flushmount style TSTACCPQ501 Thermostat Auto Changeover 7 day prog Slimline Style PART NO DESCRIPTION TSTATCCSAC01 Thermostat Manual Changeover 5 2 Day Programmable F C 1 Stage Heat 1 Stage Cool TSTATCCSHP01 Thermostat Manual Changeover 5 2...

Page 7: ...urrounding wall area located behind thermostat Thermostat conversion kit is a 24 vac accessory that can turn a 4 wire thermostat application into a 5 wire application This kit can also be used to replace a broken thermostat wire or add an extra wire when needed Do not use this kit with the AC model of the Builder s or Standard Programmable thermostat PART NO DESCRIPTION TSTATXXSEN01 B Outdoor Air ...

Page 8: ... is true for the HEAT icon and its preceding triangle located under the heat set point The 2 triangles are also used to indicate the state of the humidify and dehumidify outputs See next section Humidify dehumidify output on indicators Thermidistat Control Within humidity select screen selected by Humidity button and indicated by hu or dhu on clock display the triangle under humidity set point wil...

Reviews: