10–5
62-11637
10.2 SPLICE POINTS
* This wire runs from the splice point to the bat-
tery ground wire.
** If equipped with MAP sensor only.
10.3 WIRING SCHEMATIC
The wiring schematic is provided on the following page.
REM
A
E
F
K
Harness Connector Shown
UNITS WITH DS CONNECTOR
From
Terminal
To
(Component)
2SVM
ï
15
A
REMS1
2SVM
ï
26
B
REMS1
2MM
ï
14
E
REMSN1
2MM
ï
25
F
REMSN1
2MM
ï
15
H
REMSN2
2MM
ï
26
G
REMSN2
Unused Terminals: C,D,J, K
UNITS WITHOUT DS CONNECTOR
From
Terminal
To
(Component)
2SVM
ï
14
A
DS
2SVM
ï
25
B
DS
2SVM
ï
15
C
REMS1
2SVM
ï
26
D
REMS1
2MM
ï
14
E
REMSN1
2MM
ï
25
F
REMSN1
Unused Terminals: G,H,J, K
Splice Point No.
Component
SP
ï
1
(CAN high)
1MM
ï
2
1SVM
ï
5
ENCU
ï
23
SP
ï
2
(Ground)
SATPWR
ï
A
UL1
ï
(negative)
UL2
ï
(negative)
FP
ï
(negative)
GND1
ï
RING1*
LB
ï
G
SP
ï
3
(Ground)
AFAS
ï
B (negative)
CLH
ï
B (negative)
GND1
ï
RING1*
SV1
ï
B (negative)
SV2
ï
B (negative)
SV4
ï
B (negative)
FH1
ï
B (FH to FHTS to FH1
ï
A)
FH2
ï
B (FH to FHTS to FH2
ï
A)
SP
ï
4
(CAN low)
1MM
ï
4
1SVM
ï
7
ENCU
ï
24
SP
ï
5
(Power to K1)
3MM16
HPS
ï
B
PCM15
SP
ï
6
(Power from
“RR”)
2SVM
ï
22
ENCU
ï
22
PCM
ï
34
SP
ï
7
(+ 5V power)
CDP
ï
2
EVOP
ï
2
CSP
ï
2
2MM
ï
30
SP
ï
8
(Power from
FHR)
FH1
ï
A (FHTS to FH to FH1
ï
B)
FH2
ï
A (FHTS to FH to FH2
ï
B)
PCM
ï
3
PCM
ï
14
SP
ï
9
(Power from
SROS)
2MM
ï
35
HPS
ï
A
J1
ï
B
SP
ï
27**
(Sensor ground)
ENCU
ï
27
MAP
ï
1
RPS
ï
2
SP
ï
28**
(Sensor power)
ENCU
ï
29
MAP
ï
2
RPS
ï
1
Summary of Contents for Transicold X4 7300
Page 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Page 22: ...1 7 62 11637 62 03958 ...
Page 23: ...62 11637 1 8 ...
Page 24: ...1 9 62 11637 ...
Page 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 278: ......