7–49
62-11637
P00141
PRETRIP STOPPED BY USER
• ACTIVATION: Pretrip cycle was stopped by user before the Pretrip cycle ended automatically.
• UNIT CONTROL: Alarm Only.
• RESET CONDITION: Alarm may be manually reset using the display mounted keys or by turning the unit
off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check for any Pretrip Alarms
Scroll the alarm list for any Active Pretrip alarms. Alarm conditions must be corrected and the alarm
cleared to continue.
2.
Rerun Pretrip Check (If Desired)
a. Clear Active Alarm List, then run Pretrip & check for any new alarms. Unit is in Pretrip. Check for
any new alarms.
b. Allow to terminate automatically. Pretrip cycle operates normally.
P00143
CHECK CLUTCH CIRCUIT
• ACTIVATION: The circuit current draw is outside the normal range.
• UNIT CONTROL: Pretrip will fail in test 2 and display “PRETRIP FAIL AND COMPLETED”.
• RESET CONDITION: Auto reset if Pretrip is started again, or Alarm may be manually reset using the dis-
play mounted keys or by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (Refer to Note 1 in
Section, page 7-2.) Operate the unit through the appropriate modes to see if
any active alarm occurs. Continue with the steps below as necessary.
CORRECTIVE ACTIONS:
1.
Check Coil
a. Inspect coil & connector pins & terminals. Verify no damage to coil. Verify no damaged or corroded
pins.
b. Check resistance of coil. Refer to
for specifications.
c. Use Component Test Mode (Refer to
) to test actual current draw of the circuit. Refer to
for specifications. Verify that the actual current is within specifications.
2. Check Power and Wiring
a. Use Component Test Mode (Refer to
) to energize circuit. Check for power at CLH termi-
nal A and 3MM-11. Minimum 11 VDC. If not, check connectors and wiring between terminals. Verify no
damage, moisture or corrosion.
b. Check for ground at CLH terminal B (including SP-3) to GND 1RING1. Good ground. If not, check con-
nectors and wiring between terminals. Verify no damage, moisture or corrosion.