Summary of Contents for Transicold Supra 550

Page 1: ......

Page 2: ...MANUAL OPERATOR S Supra 550 650 750 850 950 TRUCK REFRIGERATION UNITS...

Page 3: ...p Check 9 Changing Setpoint 10 Start Stop Operation 12 Continuous Run Operation 14 Manual Defrost 15 City Speed 16 Function Change 17 Unit Data 19 Alarm Display and Reset 21 Stopping Unit 23 Product L...

Page 4: ...ined in this guide will help to minimize over the road problems In addition a comprehensive maintenance pro gram will help to insure that the unit continues to operate reliably Such a maintenance prog...

Page 5: ...erial number the refrigerant charge and quantity and the date the unit was placed in service If a problem occurs please refer to the information on this plate and make a note of the model and serial n...

Page 6: ...ne is equipped with a pressurized cooling system Under normal operating conditions the coolant in the engine and radiator is under high pressure and is very hot Contact with hot coolant can cause seve...

Page 7: ...ck the belt tension by depressing the belt with your thumb near the center of the longest free run of each belt Under moderate pressure each belt should deflect approximately 6 mm to 13mm 1 4 inch to...

Page 8: ...se or broken wires etc The radiator and condenser coils of the unit should be free of dirt bugs cardboard or any other debris that may obstruct airflow across the coils The evaporator located inside t...

Page 9: ...ION ENTER SETPOINT O i 20 35 F 1 Place the I O switch in the I position 2 If unit was previously used in Standby Mode press the ROAD key Under normal circumstances this is all that is required to star...

Page 10: ...FF MAN DEFROST CITY SPEED ROAD FUNCTION ENTER SETPOINT O i 20 35 F 2 Connect unit to appropriate power source See table on page 39 4 Press Standby key 1 Place the unit RUN STOP switch in the STOP posi...

Page 11: ...tinuous Mode If AUTO START STOP indictor is illuminated press AUTO START STOP toggle key to place unit in Continuous Mode 2 Press FUNCTION key until AUTO OP or MAN OP is displayed If MAN OP appears un...

Page 12: ...check of all normal operating modes Upon initiation the unit will cycle through all operating modes at 30 second intervals The display will show PPPP at the beginning and will show various unit data d...

Page 13: ...EFROST CITY SPEED ROAD FUNCTION ENTER SETPOINT O i Press ENTER key when desired setpoint is displayed to lock in new setpoint New setpoint will flash and then return to original setpoint if ENTER key...

Page 14: ...ory i e on initial startup the controller will lock out the run relay and flash SP on the left hand display until a valid setpoint is entered The setpoint may be changed up or down in 1 increments by...

Page 15: ...ting modes The Auto Start Stop indicator on the display will illuminate when Auto Stop Start is enabled If the indicator is not illuminated the unit is in the Continuous Run Mode Automatic start stop...

Page 16: ...eria have been met SBox temperature has changed by 11 F 6 1 C for setpoints in the perishable range and 11 F 6 1 C for setpoints in the frozen range DURING minimum off time SBox temperature has moved...

Page 17: ...place unit in Continuous Run mode AUTO START STOP indicator will not be illuminated In the Continuous Run mode the diesel engine will run continuously providing constant air flow and temperature cont...

Page 18: ...s by the defrost timer in the microprocessor 2 Defrost is initiated by the defrost air switch 3 The defrost mode may be manually initiated by pressing the Manual Defrost Key The defrost mode terminate...

Page 19: ...i 20 35 F 1 Press the CITY SPEED key to toggle between low speed only and normal operating mode The CITY SPEED key enables the city speed mode of operation In the city speed mode the unit will operate...

Page 20: ...ability to change any functional parameters is disabled DEFR 12 0H The Function Parameters control selected operating features of the unit When multiple choices are available the display will show th...

Page 21: ...e FN4 a REM PROBE Controlling Probe Return Air FN4 b SUP PROBE Controlling Probe Supply Air FN5 Degrees F or C Temperature Unit _C or _F FN6 ON TIME STRT Maximum Off time 30 Min FN6 OFF TEMP STRT Temp...

Page 22: ...To scroll through the list faster use the UP or DOWN ARROW keys 3 Data will display for 5 seconds 4 Press the ENTER key to display data for 30 seconds 5 The display will revert back to the default di...

Page 23: ...M Remote Air Temperature CD7 ATS Ambient Temperature CD8 EVP Future Expansion CD9 CDT Discharge Temperature CD10 BATT Battery Voltage CD11 SBY Standby Hours CD12 MOD V Future Expansion CD13 REV Softwa...

Page 24: ...LARM FAULT STANDBY BUZZER OFF MAN DEFROST CITY SPEED ROAD FUNCTION ENTER SETPOINT O i ENG OIL 3 Press ENTER to clear alarm ALARM CLR will be displayed Unit will restart if alarm condition has been cor...

Page 25: ...DEFR FAIL Defrost Override AL7 ALT AUX No Alternator Auxiliary Output AL8 STARTER Starter Motor Fault AL9 RA SENSOR Return Air Sensor Fault AL10 SA SENSOR Supply Air Sensor Fault AL11 WT SENSOR Coola...

Page 26: ...DATA PRETRIP ALARM FAULT STANDBY BUZZER OFF MAN DEFROST CITY SPEED ROAD FUNCTION ENTER SETPOINT O i 20 35 F 1 To stop the unit place the I O switch in the O position The diesel engine electric motor w...

Page 27: ...of the load and the ceiling to ensure that there is nothing to prevent airflow to the rear of the body D Load product on pallets to provide free air return to unit and improve product protection Prope...

Page 28: ...acked tightly in the center of the trailer All products should be kept away from the side walls of the body to allow air flow between the body and the load this prevents heat filtering through the wal...

Page 29: ...esh meats and seafood 28 to 32 2 to 0 Auto Start Stop or Continuous Dairy Products 33 to 38 0 5 to 3 Auto Start Stop or Continuous Ice 15 to 20 10 to 7 Auto Start Stop Frozen fruits and vegetables 10...

Page 30: ...battery connections Check all fuses Unit won t start Check fuel level Check all fuses Unit won t run Check fuel level Check engine oil level Check all fuses Unit stops running Check belts Check engine...

Page 31: ...s in a defrost override mode AL7 ALT AUX The alternator signal is not present with the engine running or with the standby electric mode active Check alternator AL8 STARTER The starter motor input sign...

Page 32: ...n main board and the display board has been interrupted AL18 SERVICE 1 Hour meter is greater than maintenance hour meter 1 AL19 SERVICE 2 Hour meter is greater than maintenance hour meter 2 AL20 RAS O...

Page 33: ...relays that protect the unit are located on the relay board in the control box on the roadside of the unit They may be accessed by loosening the screws that hold the control panel closed EFHR3 F2 F1...

Page 34: ...ator Fan Motor 3 Fuse 20A F11 Fuel Pump Fuse 5A F12 Fuel Heater Fuse on fuel adding har ness 25A Relay Identification Desig Item SSR Starter Solenoid Relay EFMR1 Electric Fan Motor Relay EFMR2 Electri...

Page 35: ...use of oil of the proper weight viscosity is also essential The following chart indicates the SAE Weight Rating of the oil to be used in various climates _F _C 10W or 10W30 20W or 15W40 30W or 15W40 T...

Page 36: ...Bypass At 250 Hours D Check engine cooling system D Check and clean the air filter D Check all bolts screws and unit mounting bolts for tightness Tighten as required D Check all belts Petroleum Oil W...

Page 37: ...necessary Petroleum and Synthetic Oil With and With out Bypass At 2000 Hours D Replace oil filter D Clean radiator condenser coil D Check refrigerant level Petroleum and Synthetic Oil With and With ou...

Page 38: ...D Replace lube oil and filter D Check engine cooling system D Check and clean the air filter D Check all belts Petroleum and Synthetic Oil With and With out Bypass At 1500 Hours D Check fuel pump fil...

Page 39: ...speed High 2300 to 2350 Low 1800 to 1850 Petroleum and Synthetic Oil With and With out Bypass With Standard Cool ant At 6000 Hours D Check all belt tension pulleys D Change anti freeze and flush cooli...

Page 40: ...e of the dry air filter D Check battery terminals and fluid level D Check compressor oil level Use polyol ester oil POE approved by CARRIER D Check alternator brushes Check for diesel and standby hour...

Page 41: ...0 Hours 1500 Hours 2000 Hours W Bypass 1200 Hours 2000 Hours N A Maximum oil drain interval is one year 12 months Mobil Delvac1 is the only approved synthetic oil Maximum oil drain interval is two 2 y...

Page 42: ...Requirement 208 230 V 60 hz 3 phase 15 8 A 50 A 8 3 with ground up to 50 ft 460 V 60 hz 3 phase 13 2 A 30 A 10 3 with ground up to 75 ft D When multiple units are in use each unit must be operated on...

Page 43: ...rtstop Service Centers directory to locate the service center nearest you This directory may be obtained from your Carrier Transicold dealer If you are unable to reach a service center call our 24 hou...

Page 44: ...A 30601 USA Tel 1 706 357 7223 Fax 1 706 355 5435 Central America and Mexico Ejercito Nacional No 418 Piso 9 Torre Yumal Col Chapultepec Morales 11570 Mexico D F Tel 5255 9126 0300 Fax 5255 9126 0373...