Summary of Contents for TOTALINE Gold P274-0100-C

Page 1: ...et tings ale preserved with the power off when optional batteries are used INSTALLATION CONSIDERATIONS Power All non programmable thermostats can be dual powered either by battery operation or electrical operation AA batteries are included wifll the product Models Ensure the proper thermostat is selected for the intended application Refer to Fig 1 for thermostat dimensions Select from the followin...

Page 2: ...ing holes 5 Drill two 3 lr in mounting holes in wall where marked 6 Secure mounting base to wall with 2 anchors and screws provided additional anchoring holes available for more secure mounting if needed making sure all wires extend through hole in mounting base 7 Adjust length and routing of each wire to reach proper terminal and connector block on mounting base with I 4 in extra wire Strip only ...

Page 3: ...to the maximum of 6 cycles per hi To adjust 1 Enter Configuration mode 2 Use up and down buttons to display Option 01 The SET icon should be off 3 Press MODE button once The SET icon will appeac Option 01 setting is now displayed 4 Use up and down buttons to move between the avail able Option 01 values of 1 to 9 The factory default is 3 5 Press MODE button again to return to Option 01 The SET icon...

Page 4: ...ure is above a selected tempemtme Temperatures of 5 to 55 F can be selected Feature can be disabled by selecting OR Emergency heat EHEAT mode always overrides this feature To select or adjust 1 Enter Configuration mode 2 Use up and down buttons to display Option 08 The SET icon should be off 3 Press MODE button once The SET icon will come on The display now shows Option 08 setting 4 Use up and dow...

Page 5: ...it Configuration mode OPTION 21 KEYPAD LOCKOUT In OF off mode the keypad is not locked out and has full functionality In ON mode the keypad is locked out and the lock icon on the display is illuminated To unlock the keypad the user must press and hold the up and down buttons simultaneously for approxi mately 5 seconds The lock icon is turned off and the keypad will remain unlocked as long as the u...

Page 6: ...W2 B N A OFF R C G Y1 Y Y2 W W1 Cool Cool Reversing Valve Stage 1 Stage 2 Y Y2 N A N A Y Y2 N A O W2 B Y Y2 N A N A Y1 Y Y2 N A Y1 Y Y2 O W2 B Model Numbers P274 0100 C P274 0200 C P274 0300 C MODEL 0100 C THERMOSTAT 24VAC HOT 24VACCOMM HEATSTAGE 1_ El OOOLSTAGE1 5Z E FAN IN HUM r l See Note 11 Fig 2 Single Speed Air Conditioner with Single Stage Heat SINGLE STAGE SINGLE SPEED FURNACE AIR CONDITIO...

Page 7: ...tes 2 58 and 11 Fig 8 Single Speed Air Conditioner with Single Stage Heat MODEL 0200 C TYPICAL SINGLE SPEED THERMOSTAT FAN COIL HEAT PUMP 24 VAC HOT _1 _ __ ___ _ _ _ I_ __ FI 4woco FAN _ _J_ t t CO S_GHEI_T _q F1 HEATSTAGE 2 _ _______t___ _ RVSCOOL NG_ _ N A _r_ N A OUTDOOR I FI SENSOR _1 See Notes 6 7 10 and 11 CONNECTION LD Fig 7 Single Speed Heat Pump with Typical Fan Coil TWO STAGE OR MODEL 0...

Page 8: ...le Speed Air Conditioner with Variable Speed FK4D FV 40FK Fan Coil MODEL 0300 C THERMOSTAT I I 24 VAC HOT RL_ _ _ D 24 VAC COMM COOL HEAT STAGE 2 V _ c HEAT STAGE 3 I I I RVS COOLING IO B_21 COOL HEAT B STAGE 1 N A OUTDOOR ____ SENSOR CONNECTION TYPICAL TWO SPEED FAN COIL HEAT PUMP ____ _ __ F_ _ __ q Fq See Notes 5 6 78 10 and 11 Fig 11 Two Speed Heat Pump with Typical Fan Coil MODEL 0200 C EASY ...

Page 9: ... Pump with Variable Speed FK40 FV4 40FK Fan Coil NOTES FOR FIG 2 16 1 Furnace must control its own second stage heat operation via furnace control algorithm Refer to indoor equipment Installa tion Instructions for proper setup 2 See Option 5 information to convert HP and 2S thermostats to AC thermostat operation 3 As an option lock the furnace into low heat operation and let O W2 B control high he...

Page 10: ...ion via the following 2 digit code AC 1 speed air conditioneL HP l speed heat pump A2 2 speed air conditioner H2 2 speed heat pump Error Codes If the thermostat cannot properly read room temperature the display will indicate 2 dashes and all outputs except the fan if on will turn off This is to plevent operation of the equipment if the thermostat has failed E2 If the AC line voltage drops below a ...

Page 11: ...s F or C factory default F Fan On with W Wl output OF or ON factory default OF HP 2 speed AC Configuration Cooling Ix ckout OF or ON factory default OF Zoning Selection OF or ON factory default OF Auxiliary Heat Lockout OF or 5 to 55 F factory default OF N A O Reversing Valve ON with Heat or Cool Selection default C present on Heat Pump models only N A Room Temperature Offset 5 to 5 factory defaul...

Page 12: ... or change at any time specincatlons or designs without notice and without Incurring obligations REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION 2004 9 04 PRINTED IN U S A LITERATURE NUMBER P274 7SI REPLACES 997 510011 19 CATALOG NUMBER 570 351 ...