TB---NAC

TB---NHP

Base Series

Non---Programmable Thermostat

Homeowner’s Guide

A07108

Base Non---Programmable Thermostat

1. To Select the Mode:

Use the H/C button to move between the choices. OFF,

HEAT, COOL, or EMHT will appear on the display. EMHT
will only appear on heat pump models.

2. To Select the Fan Operation:

Use the FAN button to move between continuous fan
(indicated by the FAN ON icon) and auto fan operation.

3. To Read the Room Temperature:

The large display reads room temperature until a button is
pressed.

4. To Adjust the Setpoint:

In normal operation, the large display shows room

temperature. At the first press of the UP or DOWN button,
the large display shows the current setpoint and the SET
TEMP icon is turned on. Further presses of the UP or

DOWN button adjust the setpoint upward or downward.
Five seconds after the last button press, the display returns

to the room temperature and the SET TEMP icon turns off.

Summary of Contents for TB-NAC

Page 1: ...rol room temperature in both the heating and air conditioning modes The thermostat is designed to maintain 2_F accuracy No batteries are required temperature fan mode and installer configuration settings are preserved with power off INSTALLATION CONSIDERATIONS Air Conditioner Model TB NAC Base Series Model air conditioner thermostat may be wired with or without connecting a common wire between the...

Page 2: ...ption 10 O reversing valve On with Heat or Cool present on Heat Pump model only Option 13 Room temperature offset adjustment Note that not all configuration option numbers are used in this product To Enter The Configuration Mode Press and hold FAN button for approximately 10 sec until room temperature disappears and the display reads 01 You are now in configuration mode NOTE If FAN button is press...

Page 3: ...e the equipment has turned on it will remain on for a minimum of 3 minutes regardless of demand However the equipment can turn off in less than 3 minutes if a change in setpoint or a change in mode occurs Staging Timer If the thermostat is a heat pump model it has 2 stage heat capability With HP operation there is a 15 minute delay between the first and second stages of heat The Y output will ener...

Page 4: ...Typical Installation Copyright 2007 Carrier Corp S 7310 W Morris St S Indianapolis IN 46231 Printed in U S A Edition Date 02 07 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No TB NAC 1SI Replaces NEW TB NAC TB NHP ...

Page 5: ...dicated by the FAN ON icon and auto fan operation 3 To Read the Room Temperature The large display reads room temperature until a button is pressed 4 To Adjust the Setpoint In normal operation the large display shows room temperature At the first press of the UP or DOWN button the large display shows the current setpoint and the SET TEMP icon is turned on Further presses of the UP or DOWN button a...

Page 6: ...ES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED...