background image

4

* ABCD Connections are in Parallel with each other.
   Smart Sensors and Equipment may be connected in any combination.

For easier troubleshooting, the installer may elect to use one terminal block
for wall control and smart sensor connections, and the other for equipment connections.

NOTE:

DAMPER CONTROL MODULE

ZONES 1-4

A B C D

RED

GREEN

YELLOW

WHITE

SMAR

T

 SENSOR(S)

T

O W

ALL

 CONTROL,  

AND/OR

DAISY CHAIN

OPTION

TO OTHER

SMART SENSORS

IF AVAILABLE

TO EQUIPMENT OR

ACCESSORY CONNECTIONS

A

B

C

D

RED

COMMUNICATION

BUS

*

GREEN

YELLOW

WHITE

A

B

C

D

RED

GREEN

YELLOW

WHITE

A B C D

RED

GREEN

YELLOW

WHITE

A B C D

RED

GREEN

YELLOW

WHITE

A B C D

RED

GREEN

YELLOW

WHITE

T

O EQUIPMENT

AND/OR

DAMPER CONTROL

 MODULE

(ZONES 5-8)

A04135

Fig. 3 -- Typical Smart Sensor Wiring diagram

Copyright 2012 Carrier Corp.

S

7310 W. Morris St.

S

Indianapolis, IN 46231

Edition Date: 10/12

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No: ZONESMS---02SI

Replaces: ZONESMS--- 1SI

Summary of Contents for SYSTXCCSMS01-A

Page 1: ...one It also displays outdoor temperature and indoor humidity When used with an Infinityr Touch Control wall control FAN HOLD and HOLD UNTIL features are available When used with an Infinityr User Interface UIZ wall control FAN HOLD OVERRIDE UNOCCUPIED features are available INSTALLATION CONSIDERATIONS Any zone may use an Infinity Smart Sensor The Infinity Smart Sensor can be home run wired directl...

Page 2: ...Push any excess wire into the wall Seal hole in wall to pre vent any air leaks Leaks can affect Smart Sensor operation 7 Attach Infinity Smart Sensor to the mounting base by lining up the plastic guides and gently snapping assembly togeth er ELECTRICAL OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation Improper wiring or installation may damage the...

Page 3: ...ton While the timer or default time is shown the TIME buttons can be used to raise or lower the Override timer or the default time in 15 minute increments up to a maximum of 24 hours If the time is decreased to zero the OVERRIDE text disappears along with the timer or the default time will be replaced with SCHEDULED depending on the type of wall control and the program resumes regular operation NO...

Page 4: ... TO OTHER SMART SENSORS IF AVAILABLE TO EQUIPMENT OR ACCESSORY CONNECTIONS A B C D RED COMMUNICATION BUS GREEN YELLOW WHITE A B C D RED GREEN YELLOW WHITE A B C D RED GREEN YELLOW WHITE A B C D RED GREEN YELLOW WHITE A B C D RED GREEN YELLOW WHITE TO EQUIPMENT AND OR DAMPER CONTROL MODULE ZONES 5 8 A04135 Fig 3 Typical Smart Sensor Wiring diagram Copyright 2012 Carrier Corp S 7310 W Morris St S In...

Reviews: