INSTALLATION INSTRUCTIONS
Fig.4
Correct orientation
of Installation Plate
Wall
Indoor
Outdoor
5
-7
m
m
Fig.6
Fig.5
Indoor unit installation(wall-mounted type)
2. Drill a hole in the wall
Note:
1. Fit the Installation Plate
1 . F it th e i nstal l a t i o n p late ho r izontally
o n s tructural p a rts of t h e wal l w ith
s p a c e s a round t h e ins t a l l a t i o n plat e .
2 . I f th e w all is m ade of b rick, co n c rete
o r t he li k e , d rill fi v e o r ei g h t 5 mm dia m e t e r
h o l e s i n th e w all.Ins e r t C lip an c h o r f or
a p p r o p r iate mo u n t i n g s crew s .
3 . F it th e i nstal l a t i o n p late on t he wa l l
w i t h f ive or e ight typ e ? A ? scr e w s .
Fit the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The Installation Plate may be
slightly different according to the
different models of indoor unit.
(
Dimensio n s a re in ? m m? un l e s s
ot h erwise st a t e d )
1. Determine hole positions according
to the diagramdetailed in Fig.5. Drill
one (1) hole (
φ
65mm) slanting slightly
to outdoor side.
2. Always use wall hole conduit when
drilling metal grid, metal plate or the like.
3. Connective Pipe and Drainage
Installation
1. Run the drain hose sloping downward.
Do not install the drain hose as
illustrated in Fig.7.
Drainage
Fig.7
Do not block water flow by a rise.
Do not put the end of
drain hose into water.
150mm or more to ceiling
Indoor unit outline
Installation plate
292
Right rear side
refrigerant
pipe hole
φ
65
Left rear side
refrigerant
pipe hole
φ
65
120mm or
more to wall
120mm or
more to wall
918
45
190
150
45
A
45
B
Right rear side
refrigerant
pipe hole
φ
65
Installation plate
Indoor unit outline
Left rear side
refrigerant
pipe hole
φ
65
150mm or more to ceiling
120mm or
more to wall
120mm or
more to wall
Model A (A: 710, B: 250, C:100, D: 110)
Model A (A: 710, B: 250, C:100, D: 110)
Model A (A: 920, B: 293, C:150, D: 185)
Model B(
)
A: 790, B:265, C:100, D: 150
Model B(
)
A: 790, B:275, C:100, D: 85
Model C(
)
A: 850, B:290, C:100, D: 115
Model B(
)
A: 995, B:293, C:150, D:200
Model C(
)
A: 850, B:305, C:150, D:145
45
C
D