background image

13

14

The Follow me function enables the 
remote control to measure the temperature 

at its current location and 

When using AUTO, COOL, or HEAT modes, 
measuring ambient temperature from the 
remote control (instead of from the indoor 

unit itself) will enable the air conditioner to 
optimize the temperature around you and 
ensure maximum comfort.

send this signal 

to the air conditioner every 3 minutes interval

FOLLOW ME function

ECO function

Silence function

SLEEP Function

O

8 C Heating  Function

The SLEEP function is used to decrease 
energy use while you sleep (and don t 
need the same temperature settings to 
stay comfortable). This function can 
only be activated via remote control.   

Note: 

in 
MODE, FAN, TURBO, SELF CLEAN or 
ECO button will stop sleep operation. 

The SLEEP function is not available 

FAN or DRY mode. Press ON/OFF,

,

How To Use The Advanced Functions

How To Use The Advanced Functions

The TURBO function makes the unit work 
extra hard to reach your present temperature 

in the shortest amount of time possible.  
   When you select 

TURBO

 feature in COOL 

   mode, the unit will blow cool air with 
   strongest wind setting to jump-start the 
   cooling process.
    
    
       

  

    When you select 

TURBO

 feature in HEAT 

    mode, for units with Electric heat elements, 
    the Electric Heater will activate and 
    jump-start the heating process.  

TURBO function(TURBO/FRESH) function

For the detail, see   sleep operation   in 
  USER S MANUAL.  

,

, ,

, ,

,,

,,

NOTE:

 This function is only available under 

COOL mode.
  

  

Hold down Fan speed button for 2 seconds
to activate/cancel 

Silent

 mode. Due to low 

frequency operation of compressor, it may 
result in insufficient cooling and heating 
capacity. (applicable to the air conditioner 
with Silent feature only)

Mode 

Mode 

Fan

Fan

ON/OFF

ON/OFF

When the air conditioner operates under 
heating mode with the set temperature 

O

of 16 C, press Temp      button twice in 
one second will activate 8 Degree heating 
function. The unit will operate at a setting 

O

temperature of 8 C. The indoor unit 
display shows    FP   .  For some units,

O

press this button can activate 12 C 
heating feature, please refer to the 
  Owner s Manual   of the air conditioner.  

,,

, ,

Used to enter the energy efficient mode.
Under cooling mode, press this button, 
the remote controller will adjust the 

O

temperature automatically to 24 C, fan 
speed of Auto to save energy(but only 

O

if the set temperature is less than 24 C). 

O

If the set temperature is above 24 C , 
press the ECO button, the fan speed 
will change to Auto, the set temperature 
will remain unchanged.

NOTE:

Pressing the ECO button, or modifying 
the mode or adjusting the set temperature  

O

to less than 24 C will stop ECO operation.
Under ECO operation, the set temper-

O

ature should be 24 C or more. it may 
result in insufficient cooling. If you feel 
uncomfortable, just press the ECO 
button again to stop it.

Airborne bacteria can grow in the moisture
that condenses around heat exchanger in 
the unit. With regular use, most of this 
moisture is evaporated from the unit. 
When the Self clean feature is activated, 
your unit will clean itself automatically. After
cleaning the unit will turn off automatically. 
 

You can use Self clean feature as often as 
you like. 

 

Note:

 You can only activate this function

            in COOL or DRY mode.
  

 

Note:

 The Intelligent eye function will stop if

 you press the other buttons except Timer and
 LED buttons.
  

SELF CLEAN  function

NOTE:

 Press and hold  Temp       and

       buttons together for 3 seconds will 
alternate the temperature display 

O

O

between the   C &   F scale.

LOCK function

Press Turbo button and Self clean
button simultaneously for one second 
to lock or unlock the keyboard.

Hold together for one 
second to activate
LOCK function
  

Hold down Fan 
button for 2 
seconds to activate 
Silence function
  

Press this button 
twice in one second

O

to activate 8 C 
heating function
  

Timer

Timer

LED

 Self

clean

Turbo

Timer

Timer

LED

Turbo

 Self

clean

Follow

  me

INTELLIGENT EYE function

Press the          button to activate wind flow
follow people feature, the fan speed is Auto,
and the auto swing feature is activated.
Press it again to stop and activate the wind
flow away people feature. The fan speed is
Auto, and the auto swing feature is turned off.
Press it the third time to stop the wind flow 
away people feature.

Follow

  me

,,

, ,

,

Hold down Eco 
button for 2 seconds 
to activate/cancel
SLEEP function.
  

Hold down Turbo/Fresh button for 2 seconds, 
the Fresh feature will be activated. The 
Ionizer/Plasma Dust Collector(depending on 
models) is energized and will help to remove 
pollen and impurities from the air (For model
RG66B4(2H)/BGEF only).

Summary of Contents for RG66B3/BGEF

Page 1: ...hasing our air conditioner Please read this owner s manual carefully before using your air conditioner Make sure to save this manual for future reference The design and specifications are subject to c...

Page 2: ...purchased is cooling only type Heat mode is not supported by the cooling only appliance Mode Fan Timer Timer Follow me LED Self clean Turbo ON OFF FAN ON OFF Turns the unit on or off MODE Scrolls thro...

Page 3: ...unsorted municipal waste Refer to local laws for proper disposal of batteries HANDLING THE REMOTE CONTROLLER Remove the back cover to install batteries Put the remote controller in the holder Mode Fa...

Page 4: ...lear presentation But during the actual Transmission Indicator Horizontal louver auto swing display Vertical louver auto swing display Wind flow follow people Wind flow away from people Not available...

Page 5: ...w NOTE As outdoor temperature drops the performance of your unit s HEAT function may be affected In such instances we recommend using this air conditioner in conjunction with other heating appliance H...

Page 6: ...fter which the unit will automatically turn off such as when you wake up ON OFF MOD E FA N SH OR T CU T TIMER ON TIMER OF F TE MP SLEE P 3sec 1 3 2 4 TIMER ON function The TIMER ON function allows you...

Page 7: ...mind that the time periods you set for both functions refer to hours after the current time For example say that the current time is 1 00 PM and you want the unit to turn on automatically at 7 00 PM Y...

Page 8: ...ooling mode press this button the remote controller will adjust the O temperature automatically to 24 C fan speed of Auto to save energy but only O if the set temperature is less than 24 C O If the se...

Page 9: ......

Reviews: