Model number nomenclature

 

38TXA

024

3

0

1

Deluxe 13 SEER Split-System
Air Conditioner

Packaging

Series

Nominal Capacity

 

024 — 24,000 Btuh

042 — 42,000 Btuh

030 — 30,000 Btuh

048 — 48,000 Btuh

036 — 36,000 Btuh

060 — 60,000 Btuh

 

Electrical

 

3 — 208/230-1

 

surfaces utilized in Carrier’s 38TXA 
design allow heat to easily be transferred 
to the outdoor air and requires less energy. 
The unique scroll compressor found in the 
38TXA design performs quietly and adds 
to the overall efficiency of the system. 
Finally Carrier’s unique Puron® 
refrigerant operates more efficiently than 
ordinary R-22 refrigerant found in other 
systems. The efficiency levels provided by 
the 38TXA provide end users with lower 
costs of operation than traditional air 
conditioning systems.

 

Assured Future Service

 

— By utilizing 

the environmentally sound refrigerant, 
Puron®, 38TXA models will remain 
serviceable well into the future. The Clean 
Air Act of 1990 has placed a cap on 
production of most other refrigerants 
which has scheduled reductions 
beginning in 2004. The resulting cap in 
production ultimately results in a 
complete ban on many other refrigerants 
in new equipment by the year 2010. These 
changes, required by federal law, mean 
the supply of other refrigerants may be 
limited in the near future making Puron® 
the correct choice when considering long 
term serviceability.

 

Highly Reliable Performance

 

— Is 

delivered through the superior design of 
the system and componentry. The 
reliability of the 38TXA models has been 
proven to provide the lowest incidence of 
warranty service of any product in the 
Carrier family in its past 3 years of 
service. Long term reliability is assured 
through the use of both high and low 
pressure switches which will not allow the 
system to operate in the event of a 
significant change in operating pressure. 

In doing this, the system is protected from 
damage if an unusual condition arises. 
Finally, Carrier includes a special liquid 
line filter drier designed to trap moisture 
and contaminants which could otherwise 
shorten the life of the system.

 

Carrier’s Silencer System

 

— Is one of 

the most sought after features of the 
38TXA family. Extremely low operating 
sound is the result of special attention to 
the air moving through the outdoor unit, a 
specially designed sound enclosure 
surrounding the compressor, and an 
exclusive laminated plate beneath the 
compressor to eliminate sound 
transmission to the rest of the system.

 

Application Versatility

 

— Carrier’s 

systems utilizing Puron® refrigerant have 
the same application guidelines as other 
systems. Applications which include long 
line sets (50 to 175 ft) or applications 
which require the system to operate at low 
outdoor temperatures (below 55°F) are 
approved under Carrier’s standard 
guidelines.

 

Carrier Coils and Fan Coils to 
Complete the System

 

— Carrier 

specially designs both the outdoor 
product and indoor coil products to 
operate with assured reliability and 
performance. A wide range of indoor coil 
options are listed in the ratings section of 
this publication.

 

Special Protective Devices

 

— High and 

low pressure switches and internal 
protection in the compressor including 
temperature and current sensing 
overloads prevent operation under 
potentially damaging circumstances. A 
special liquid line filter drier designed to 

trap nearly 4 times the volume of 
contaminants of standard driers provides 
superior protection from moisture trapped 
in the system.

 

Electrical Range

 

— 208/230 volt, 

single phase only.

 

Wide Range of Sizes

 

— Available in six 

sizes 2, 2-1/2, 3, 3-1/2, 4 and 5 tons.

 

Totally Enclosed Fan Motor

 

Protected from adverse weather 
conditions.

 

Unit Design

 

— Enhanced copper and 

aluminum heat transfer surfaces with 
vertical air discharge to direct air up and 
away from the area.

 

External Service Valves

 

— Both 

service valves are back seating type valves 
which are externally located. These 
unique valves allow service technicians to 
evacuate or charge the system in less time 
than standard service valves.

 

Easy Serviceability

 

— Removal of one 

panel provides access to both electrical 
and refrigerant carrying components 
simplifying installation and service.

 

Agency Approvals

 

— 38TXA models 

are listed with UL, c-UL, ARI, CEC, and 
CSA-EEV. Special endorsements have 
also been awarded these products by 
Green Seal an independent organization 
monitoring environmental concerns and 
Energy Star® which recognizes energy 
efficient products.

 

Limited Warranty

 

— A standard one 

year warranty on parts with extended 
warranty coverage on the compressor for 
a total of 10 years. Optional warranties are 
available through your Carrier distributor.

  

M

A

N

U

F

A

C

T

U

R

E

R

CE

RT

IFIED

TO ARI

AS

C

O

M

P

L

Y

IN

G
W
IT

H

A

RI

STANDARD

21

0

U

N

IT

A

R

Y

AIR

CO

N

D

IT

IO

N

IN

G

EQUIPMENT

 

CERTIFICATION APPLIES ONLY WHEN THE
COMPLETE SYSTEM IS LISTED WITH ARI.

REGISTERED QUALITY SYSTEM

As an ENERGY STAR® partner, Carrier Corporation 

has determined that this product meets the ENERGY 

STAR® guidelines for energy efficiency.

This product meets Green Seal criteria for 

manufacturing, energy efficiency, sound levels,

and packaging. It contains no CFCs or HCFCs.

  

Summary of Contents for Puron 38TXA

Page 1: ...oth finish that will last for many years All screws on the cabinet exterior are SermaGuard coated for a long lasting rust resistant quality appearance The coil is protected with an enhanced coil guard With spacing of 3 8 in and construction of coated 12 gage wire the guard helps to protect from inclement weather hail vandalism and incidental damage Puron Environmentally Sound Refrigerant Is Carrie...

Page 2: ... Versatility Carrier s systems utilizing Puron refrigerant have the same application guidelines as other systems Applications which include long line sets 50 to 175 ft or applications which require the system to operate at low outdoor temperatures below 55 F are approved under Carrier s standard guidelines Carrier Coils and Fan Coils to Complete the System Carrier specially designs both the outdoo...

Page 3: ...ass Type Charge Lb 6 00 6 00 6 88 8 75 10 13 12 00 COND FAN Propeller Type Direct Drive Air Discharge Vertical Air Qty CFM 2400 2400 2800 2800 3300 3300 Motor HP 1 8 1 8 1 5 1 5 1 4 1 4 Motor RPM 825 825 825 825 1100 1100 COND COIL Copper Tube Aluminum Plate Fin Face Area Sq ft 15 2 12 2 15 2 18 2 18 2 18 2 Fins per In 25 25 25 25 20 20 Rows 1 1 1 1 2 2 Circuits 2 2 2 3 5 5 VALVE CONNECT In ID Swe...

Page 4: ... Bearing Fan Motor Sizes 048 060 KH45LG140 RCD Filter Drier Suction Line Sizes 024 036 KH45LG141 RCD Filter Drier Suction Line Sizes 042 060 KAALS0201LLS Liquid Line Solenoid Valve Sizes 024 048 Standard Liquid Line Solenoid Valve Size 060 KSASF0101AAA Support Feet All Sizes KAACF0201MED Coastal Filter All Sizes THERMOSTAT SUBBASE PKG DESCRIPTION TSTATCCNAC01 B Thermostat Auto Changeover Non Progr...

Page 5: ...d Service Manual 10 Low Ambient Controller Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits approximately 100 F high and 60 F low The control will maintain working head pressure at low ambient tempe...

Page 6: ...not to exceed 2 Time delay fuse FLA Full Load Amps LRA Locked Rotor Arms MCA Minimum Circuit Amps RLA Rated Load Amps NOTE Control circuit is 24 v on all units and requires external power source Copper wire must be used from service disconnect to unit All motors compressors contain internal overload protection SOUND POWER dBA UNIT SIZE SERIES V PH OPER VOLTS COMPR FAN FLA MCA 60 C MIN WIRE SIZE 75...

Page 7: ... ambient control is used max 125 F 2 Series designation is the 13th position of the unit model number 3 Center of gravity 4 NOTES A97084 DIMENSIONS IN UNIT SIZE SERIES UNIT DIMENSIONS MINIMUM MOUNTING PAD DIMENSIONS A B C D E F G H J K L M N 024 30 33 13 16 30 34 15 16 4 9 3 4 21 1 2 27 7 8 5 8 8 3 16 17 19 3 4 15 3 4 2 15 16 26 x 32 030 30 27 13 16 30 34 15 16 4 9 3 4 15 1 2 21 7 8 3 4 8 3 16 18 ...

Page 8: ...000 TDR 14 00 14 00 12 15 CC5A CD5AW024 24 000 TDR 13 50 13 50 11 90 CC5A CD5AW030 24 000 TDR 14 00 14 00 12 15 CE3AA024 24 000 TDR 13 50 13 50 12 00 CE3AA030 24 000 TDR 14 00 14 00 12 25 CJ5A CK5A CK5BW024 24 000 TDR 13 50 13 50 12 00 CJ5A CK5A CK5BW030 24 000 TDR 14 00 14 00 12 20 CK3BA024 24 000 TDR 13 50 13 50 12 00 CK3BA030 24 000 TDR 14 00 14 00 12 20 COILS 58MVP080 14 VARIABLE SPEED FURNACE...

Page 9: ...4 00 14 00 12 10 CC5A CD5AW030 28 600 TDR 13 50 13 50 11 65 CC5A CD5AW036 29 600 TDR 14 00 14 00 12 10 CE3AA030 29 000 TDR 13 50 13 50 11 80 CE3AA036 29 200 TDR 13 50 13 50 11 90 CJ5A CK5A CK5BW030 28 600 TDR 13 20 13 20 11 55 CJ5A CK5A CK5BW036 29 600 TDR 14 00 14 00 12 10 CK3BA030 28 600 TDR 13 20 13 20 11 55 CK3BA036 29 600 TDR 14 00 14 00 12 10 COILS 58U H X V060 12 VARIABLE SPEED FURNACE CC5A...

Page 10: ...CC5A CD5AW042 35 000 TDR 13 50 13 50 11 75 CD5AW036 35 000 TDR 13 20 13 20 11 65 CE3AA036 35 000 TDR 13 00 13 00 11 55 CE3AA042 35 000 TDR 13 50 13 50 11 85 CJ5A CK5A CK5BA042 35 000 TDR 13 50 13 50 11 75 CJ5A CK5A CK5BW036 35 000 TDR 13 20 13 20 11 60 CK3BA036 35 000 TDR 13 20 13 20 11 60 CK3BA042 35 000 TDR 13 50 13 50 11 75 COILS 58MVP080 20 VARIABLE SPEED FURNACE CC5A CD5AA036 35 000 TDR 13 50...

Page 11: ...35 000 TDR 13 50 13 50 12 15 CK3BA036 35 000 TDR 13 50 13 50 12 15 CK3BA042 35 000 TDR 14 00 14 00 12 25 042 30 CD5AA048 40 500 NONE 13 00 13 00 11 20 CC5A CD5AA042 40 500 NONE 13 00 13 00 11 15 CC5A CD5AC048 40 000 NONE 12 50 12 50 11 10 CC5A CD5AW042 40 000 NONE 12 50 12 50 11 00 CC5A CD5AW048 40 500 NONE 13 00 13 00 11 20 CE3AA042 41 000 NONE 13 00 13 00 11 25 CE3AA048 41 000 NONE 13 00 13 00 1...

Page 12: ...500 TDR 13 50 13 50 11 75 CE3AA042 41 000 TDR 13 20 13 20 11 60 CE3AA048 41 000 TDR 13 50 13 50 11 65 CJ5A CK5A CK5BA042 40 500 TDR 13 00 13 00 11 65 CJ5A CK5A CK5BW048 40 500 TDR 13 50 13 50 11 85 CK3BA042 40 500 TDR 13 00 13 00 11 65 CK3BA048 40 500 TDR 13 50 13 50 11 85 COILS 58U H X V080 16 VARIABLE SPEED FURNACE CC5A CD5AA042 40 000 TDR 13 50 13 50 11 80 CC5A CD5AC048 39 500 TDR 13 00 13 00 1...

Page 13: ...A048 46 500 TDR 13 00 13 00 11 55 CE3AA060 47 000 TDR 13 20 13 20 11 95 CJ5A CK5A CK5BA060 46 500 TDR 13 00 13 00 11 70 CJ5A CK5A CK5BN060 45 500 TDR 13 00 13 00 11 95 CJ5A CK5A CK5BX060 47 500 TDR 13 50 13 50 12 05 CK3BA060 46 500 TDR 13 00 13 00 11 70 COILS 58MVP120 20 VARIABLE SPEED FURNACE CC5A CD5AA060 46 500 TDR 13 00 13 00 11 55 CC5A CD5AC048 45 000 TDR 12 50 12 50 11 20 CC5A CD5AW048 46 00...

Page 14: ... SUPPLIED ENHANCE MENT SEER EER Standard Rating Carrier Gas Furnace or Accessory TDR Accessory TXV 048 30 CC5A CD5AW060 47 000 TDR 14 00 14 00 12 50 CD5AA048 46 000 TDR 13 50 13 50 12 15 CE3AA048 46 500 TDR 13 50 13 50 12 20 CE3AA060 47 000 TDR 14 00 14 00 12 50 CJ5A CK5A CK5BA060 46 500 TDR 13 50 13 50 12 45 CJ5A CK5A CK5BW048 46 000 TDR 13 50 13 50 12 25 CJ5A CK5A CK5BX060 47 500 TDR 14 00 14 00...

Page 15: ...87 21 6 16 3 2 07 19 9 15 6 2 28 17 6 14 6 2 51 62 24 3 21 9 1 52 22 5 21 0 1 68 21 1 20 2 1 85 19 7 19 5 2 05 18 4 18 4 2 27 17 5 17 5 2 51 57 22 7 22 7 1 51 21 6 21 6 1 67 20 9 20 9 1 85 20 0 20 0 2 05 19 2 19 2 2 27 17 5 17 5 2 51 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5A CD5A...

Page 16: ... 27 27 7 22 0 2 51 25 7 21 3 2 78 22 7 20 2 3 07 63 30 3 23 1 1 86 29 0 22 7 2 05 26 3 21 6 2 25 24 1 20 6 2 47 21 8 19 6 2 73 19 6 18 7 3 01 62 29 9 29 0 1 86 28 1 27 9 2 04 26 6 26 6 2 25 25 1 25 1 2 49 23 8 23 8 2 75 21 2 21 2 3 04 57 29 5 29 5 1 85 28 2 28 2 2 04 26 6 26 6 2 25 25 3 25 3 2 49 23 5 23 5 2 75 21 1 21 1 3 04 Multipliers for Determining the Performance With Other Indoor Sections I...

Page 17: ... 1 18 3 2 68 18 9 17 4 2 96 62 29 4 27 5 1 81 27 2 26 4 1 99 25 1 25 1 2 19 23 3 23 3 2 43 22 3 22 3 2 69 20 3 20 3 2 99 57 27 9 27 9 1 80 26 4 26 4 1 99 24 7 24 7 2 19 23 7 23 7 2 43 22 6 22 6 2 70 20 4 20 4 2 99 1125 72 34 2 17 4 1 89 33 0 17 1 2 08 31 7 16 7 2 30 30 1 16 3 2 54 28 5 15 9 2 82 26 5 15 4 3 15 67 32 2 23 3 1 87 30 8 22 9 2 06 29 3 22 4 2 27 27 7 22 0 2 51 25 7 21 3 2 78 22 7 20 2 ...

Page 18: ... 2 22 4 3 62 62 35 8 34 5 2 22 33 2 32 9 2 45 31 1 31 1 2 70 30 0 30 0 3 00 28 6 28 6 3 32 25 8 25 8 3 65 57 34 8 34 8 2 22 33 3 33 3 2 45 32 0 32 0 2 72 30 7 30 7 3 01 28 3 28 3 3 32 25 9 25 9 3 65 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power CC5A CD5AA 036 1 00 1 00 COILS 58MVP060 14 V...

Page 19: ... 6 3 30 24 2 22 4 3 62 62 35 8 34 5 2 22 33 2 32 9 2 45 31 1 31 1 2 70 30 0 30 0 3 00 28 6 28 6 3 32 25 8 25 8 3 65 57 34 8 34 8 2 22 33 3 33 3 2 45 32 0 32 0 2 72 30 7 30 7 3 01 28 3 28 3 3 32 25 9 25 9 3 65 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capacity Power COILS 58MVP100 20 VARIABLE SPEED F...

Page 20: ... 57 40 5 31 4 2 85 37 6 30 1 3 15 35 0 29 1 3 48 33 1 28 3 3 87 27 9 26 0 4 24 62 41 6 40 2 2 57 38 9 38 5 2 83 36 5 36 5 3 13 35 4 35 4 3 49 32 7 32 7 3 86 30 7 30 7 4 29 57 40 7 40 7 2 56 39 0 39 0 2 83 37 6 37 6 3 15 35 8 35 8 3 49 33 5 33 5 3 87 30 7 30 7 4 29 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity...

Page 21: ...4 2 85 37 6 30 1 3 15 35 0 29 1 3 48 33 1 28 3 3 87 27 9 26 0 4 24 62 41 6 40 2 2 57 38 9 38 5 2 83 36 5 36 5 3 13 35 4 35 4 3 49 32 7 32 7 3 86 30 7 30 7 4 29 57 40 7 40 7 2 56 39 0 39 0 2 83 37 6 37 6 3 15 35 8 35 8 3 49 33 5 33 5 3 87 30 7 30 7 4 29 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capacity Power Capac...

Page 22: ...9 2 97 46 5 35 1 3 29 44 4 34 5 3 64 41 9 33 4 4 02 39 2 32 3 4 45 35 2 30 6 4 91 62 47 8 45 0 2 97 45 7 44 1 3 29 43 1 42 6 3 63 40 5 40 5 4 02 39 0 39 0 4 45 36 7 36 7 4 92 57 46 6 46 6 2 97 44 8 44 8 3 28 42 5 42 5 3 63 41 1 41 1 4 02 39 0 39 0 4 45 36 7 36 7 4 92 Multipliers for Determining the Performance With Other Indoor Sections Indoor Section Size Cooling Indoor Section Size Cooling Capac...

Page 23: ... 39 0 3 93 37 5 37 5 4 36 35 4 35 4 4 83 1800 72 53 7 26 7 3 00 52 9 26 7 3 33 50 9 26 1 3 68 47 9 25 0 4 06 45 6 24 3 4 50 42 3 23 1 4 96 67 51 5 35 9 2 99 49 5 35 3 3 30 47 2 34 6 3 65 44 8 33 9 4 04 42 0 32 8 4 46 39 1 31 9 4 93 63 48 6 35 9 2 97 46 5 35 1 3 29 44 4 34 5 3 64 41 9 33 4 4 02 39 2 32 3 4 45 35 2 30 6 4 91 62 47 8 45 0 2 97 45 7 44 1 3 29 43 1 42 6 3 63 40 5 40 5 4 02 39 0 39 0 4 ...

Page 24: ... 1 4 69 49 4 46 3 5 21 45 2 44 4 5 78 41 2 41 2 6 41 57 56 3 56 3 3 77 54 1 54 1 4 21 50 9 50 9 4 67 47 9 47 9 5 20 44 7 44 7 5 78 41 2 41 2 6 41 1800 72 69 4 33 8 3 96 66 3 32 6 4 39 62 8 31 2 4 87 58 2 29 4 5 38 54 8 28 4 5 96 51 0 27 3 6 60 67 65 4 43 3 3 91 62 3 42 0 4 34 59 3 41 1 4 83 55 5 39 9 5 35 51 2 38 4 5 92 46 4 36 8 6 54 63 60 8 42 2 3 87 58 3 41 4 4 30 55 0 40 2 4 78 51 1 38 7 5 30 ...

Page 25: ...35 0 2 96 20 4 146 0 3 34 40 TCG SDT KW 36 1 76 7 1 42 34 2 86 5 1 61 32 3 96 3 1 82 30 5 106 0 2 06 28 6 116 0 2 32 26 6 126 0 2 62 24 6 136 0 2 96 22 5 146 0 3 33 45 TCG SDT KW 39 5 77 8 1 43 37 5 87 5 1 61 35 4 97 2 1 82 33 4 107 0 2 06 31 3 117 0 2 33 29 2 127 0 2 62 27 1 137 0 2 96 24 7 147 0 3 33 50 TCG SDT KW 43 1 79 2 1 44 40 9 88 8 1 63 38 7 98 4 1 83 36 5 108 0 2 07 34 3 118 0 2 33 32 0 ...

Page 26: ...G SDT KW 50 6 72 0 2 10 47 9 82 0 2 39 45 2 92 0 2 71 42 6 102 0 3 08 39 9 112 0 3 49 37 2 122 0 3 96 34 4 132 0 4 48 31 5 142 0 5 06 40 TCG SDT KW 55 7 72 3 2 10 52 8 82 1 2 38 49 9 92 0 2 70 47 0 102 0 3 06 44 1 112 0 3 47 41 1 122 0 3 93 38 1 132 0 4 45 34 9 142 0 5 02 45 TCG SDT KW 60 9 73 6 2 13 57 8 83 2 2 40 54 7 92 7 2 71 51 7 102 0 3 06 48 6 112 0 3 46 45 4 122 0 3 91 42 1 132 0 4 42 38 5...

Page 27: ...s greater than 50 ft consult Residential Split System Application Guide line and Service Manual available from equipment distributor 7 If any refrigerant tubing is buried provide a 6 in vertical rise to the valve connections at the unit Refrigerant tub ing lengths up to 36 in may be buried without further consideration For buried lines longer than 3 ft consult your local distributor 8 Use only cop...

Page 28: ... direct drive propeller type discharging air upward Air Cooled Split System Air Conditioner 38TXA 2 to 5 Tons Nominal Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped with PVC coated steel wire safety...

Page 29: ...29 Typical installation A98600 AIR CLEANER FURNACE FURNACE COIL AIR CONDITIONER COMFORT VENTILATOR HUMIDIFIER COMFORT ZONE II EQUIPMENT CONTROLLER ...

Page 30: ...30 ...

Page 31: ...31 ...

Page 32: ... equipment discussed in this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pay...

Reviews: